You are here Transceivers 100G-Q28-Q28-C-01501

Brocade 100G-Q28-Q28-C-01501 Compatible 100G QSFP28 4 x 25G NRZ Passive Copper Twinax Cable, 1.5m (5ft)

Brocade 100G-Q28-Q28-C-01501 Compatible 100G QSFP28 4 x 25G NRZ Passive Copper Twinax Cable, 1.5m (5ft)

This page covers one precise cable-schedule item: Brocade 100G-Q28-Q28-C-01501 in 1.5m (5ft), supporting 100G operation through QSFP28 to QSFP28. The complete DAC assembly is identified separately from other lengths and includes verified specifications, change-control-friendly ordering details and live-link factory checks.

OEM Part Number: 100G-Q28-Q28-C-01501HT Part Number: 100G-Q28-Q28-C-01501

Product Highlights

  • Compatible alternative to Brocade 100G-Q28-Q28-C-01501
  • 100G connectivity at 100Gbps
  • Interface configuration: QSFP28 to QSFP28
  • Fixed length and part number: 1.5m (5ft), 100G-Q28-Q28-C-01501
  • Cable construction: Passive Twinax
  • Conductor specification: 30AWG
  • Maximum power consumption: ≤0.5W
  • Minimum bend radius: 33.5mm

Specifications

HT Part Number100G-Q28-Q28-C-01501
Brocade Compatible100G-Q28-Q28-C-01501
ManufacturerHT
Form FactorQSFP28 to QSFP28
Max. Data Rate100Gbps
MediaCopper
Cable TypePassive Twinax
Cable Length1.5m (4.92ft)
Jacket MaterialPVC (OFNR)
Minimum Bend Radius33.5mm
Wire AWG30AWG
Max. Power Consumption≤0.5W
Modulation Format4x 25G-NRZ to 4x 25G-NRZ
Power Supply3.3V
MTBF≈50 Million Hours
Commercial Temperature Range0 to 70°C (32 to 158°F)
Application100G Ethernet
ProtocolsQSFP28 MSA, SFF-8662, IEEE 802.3

Signal and Lane Configuration

The listed modulation format is 4x 25G-NRZ to 4x 25G-NRZ. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Network and Protocol Considerations

The intended application is 100G Ethernet. Listed interface and protocol references include QSFP28 MSA, SFF-8662, IEEE 802.3. Confirm that the host firmware and port configuration support the same operating mode.

Passive Copper Operation

A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.

Length Selection and Installation Planning

The additional half metre beyond a one-metre assembly gives 100G-Q28-Q28-C-01501 useful routing flexibility when the ports are not directly aligned. It can accommodate a different rack unit or a short service loop, but excess cable should be dressed loosely rather than folded into a tight coil.

Position Within the Length Range

100G-Q28-Q28-C-01501 occupies the middle of this family between 100G-Q28-Q28-C-0101 at 1m (3ft) and 100G-Q28-Q28-C-0201 at 2m (7ft). It adds 0.5m over the shorter option for extra routing clearance, while the next longer version adds another 0.5m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.

Structured Pathways and Serviceability

Treat the direct-attach assembly as part of the permanent pathway plan even when the link is expected to be temporary. Follow the intended horizontal and vertical managers, maintain the specified bend radius and leave service access around both ports. A small, supported service allowance is preferable to excess slack concealed inside a rack or placed under cable-tie pressure. For this assembly, the listed conductor specification is 30AWG; the minimum bend radius is 33.5mm; the stated power consumption is ≤0.5W; the jacket material is PVC (OFNR).

Power and Thermal Planning

The rated power consumption is ≤0.5W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Cable Construction and Routing

This assembly uses 30AWG conductors, PVC (OFNR) jacket, minimum bend radius 33.5mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Ordering Information

Include the part number, fixed length, quantity and required pathway or rack grouping in the order information. The host model and firmware release are useful for change-controlled deployments. Different lengths should remain separate order lines so delivered labels and packing records agree with the pathway plan. This page’s fixed configuration is 1.5m (5ft); another length must be quoted under its corresponding part number.

Brocade Compatibility and Factory Testing

Verification covers the physical connectors, expected host identity and an operating link with available diagnostic indications. We distinguish this complete check from a simple continuity test. Platform model and software release can be reviewed in advance where the installation has strict documentation or change-control requirements. Where supported by the host, link stability and diagnostic indications are reviewed together with the established link.

Shipping and Lead Time

Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. Delivery can be arranged by courier, air freight or sea freight, and goods may instead be handed to an appointed forwarder or shipped on the customer’s courier account.

Quality Assurance and Packaging

After connector inspection and link verification, the assembly is coiled without tight bends and packed with end protection. Labels can cross-reference the customer cable schedule, OEM part number and length. This supports both receiving checks and later moves, adds or changes. Volume orders can include customer references on the labels and carton list.

Frequently Asked Questions

Is this an original Brocade cable?

No. It is an HT-manufactured compatible alternative for equipment that specifies Brocade 100G-Q28-Q28-C-01501.

Are separate transceivers or patch leads required?

No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.

Can excess cable be folded into a compact bundle?

No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.

Will any matching connector operate at the same speed?

Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.

New Zealand Fiber Optics

New Zealand Fiber Optics

New Zealand Service center: New Zealand 0632, Auckland.

Factory in Asia: Shangxue Industrial Area, Shenzhen

Product Datasheets

For PDF documents of products data sheet or any general inquiry, email info@huihongfiber.com and we will send you the details.

Customer Support

For customer support, please email sales@huihongfiber.com; our Auckland service team will respond promptly.