Dell 470-ACFB Compatible 25G SFP28 Passive Copper Twinax Cable, 2m (7ft)

The 470-ACFB compatible cable combines 25G DAC connectivity with a defined 2m (7ft) pathway between SFP28 to SFP28 interfaces. It is intended for Dell equipment and is documented here as a distinct order code, allowing cable schedules, service access and related length selections to be reviewed before installation.
OEM Part Number: 470-ACFBHT Part Number: 470-ACFB
Product Highlights
- Compatible alternative to Dell 470-ACFB
- 25G connectivity at 25Gbps
- Interface configuration: SFP28 to SFP28
- Fixed length and part number: 2m (7ft), 470-ACFB
- Conductor specification: 30AWG
- Minimum bend radius: 21.25mm
Specifications
| HT Part Number | 470-ACFB |
|---|---|
| Dell Compatible | 470-ACFB |
| Manufacturer | HT |
| Connector Type | SFP28 to SFP28 |
| Max Data Rate | 25Gbps |
| Minimum Bend Radius | 21.25mm |
| Wire AWG | 30AWG |
| Cable Length | 2m (6.56ft) |
| Jacket Material | PVC (OFNR) |
| Typical Power Consumption | ≤0.5W |
| Power Supply | 3.3V |
| Temperature | 0 to 70°C (32 to 158°F) |
| Protocols | IEEE 802.3, SFP28 MSA, SFF-8402, Infiniband, EIA 364-1000 |
| Application | 25G Ethernet, Data Center, 5G Wireless |
Cable Construction and Routing
This assembly uses 30AWG conductors, PVC (OFNR) jacket, minimum bend radius 21.25mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
Length Selection and Installation Planning
470-ACFB provides 2m (7ft) for connections between separated rack units or nearby equipment positions. Plan the route around cable managers and power cords, keeping the assembly free from connector strain while avoiding a large obstruction in the airflow path.
Position Within the Length Range
470-ACFB occupies the middle of this family between 470-ACEX at 1.5m (5ft) and 470-ACEY at 2.5m (8ft). It adds 0.5m over the shorter option for extra routing clearance, while the next longer version adds another 0.5m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.
Structured Pathways and Serviceability
Treat the direct-attach assembly as part of the permanent pathway plan even when the link is expected to be temporary. Follow the intended horizontal and vertical managers, maintain the specified bend radius and leave service access around both ports. A small, supported service allowance is preferable to excess slack concealed inside a rack or placed under cable-tie pressure. For this assembly, the listed conductor specification is 30AWG; the minimum bend radius is 21.25mm; the jacket material is PVC (OFNR).
Network and Protocol Considerations
The intended application is 25G Ethernet, Data Center, 5G Wireless. Listed interface and protocol references include IEEE 802.3, SFP28 MSA, SFF-8402, Infiniband, EIA 364-1000. Confirm that the host firmware and port configuration support the same operating mode.
Passive Copper Operation
A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.
Ordering Information
Include the part number, fixed length, quantity and required pathway or rack grouping in the order information. The host model and firmware release are useful for change-controlled deployments. Different lengths should remain separate order lines so delivered labels and packing records agree with the pathway plan. Keep 470-ACFB associated with 2m (7ft) throughout the order and receiving record.
Dell Compatibility and Factory Testing
Verification covers the physical connectors, expected host identity and an operating link with available diagnostic indications. We distinguish this complete check from a simple continuity test. Platform model and software release can be reviewed in advance where the installation has strict documentation or change-control requirements. Both connectors are examined before the operating test, which includes link stability and diagnostic indications.
Shipping and Lead Time
Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. Worldwide courier services are available, with air or sea freight for consolidated shipments; freight-collect delivery and coordination with a customer’s logistics provider can be arranged.
Quality Assurance and Packaging
After connector inspection and link verification, the assembly is coiled without tight bends and packed with end protection. Labels can cross-reference the customer cable schedule, OEM part number and length. This supports both receiving checks and later moves, adds or changes. Standard protective packing is used by default, with project documentation arranged when requested.
Frequently Asked Questions
Is this an original Dell cable?
No. It is an HT-manufactured compatible alternative for equipment that specifies Dell 470-ACFB.
Can excess cable be folded into a compact bundle?
No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.
Will any matching connector operate at the same speed?
Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.
What details assist a compatibility review?
Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.
470-ACFB