800G OSFP (IHS/Finned Top) to 2× 400G OSFP (IHS/Finned Top)-800G-DAC-2.5M8FT 800G OSFP 8 x 100G PAM4 IHS/Finned Top to 2 x 400G OSFP 4 x 100G PAM4 IHS/Finned Top Passive Copper Breakout Cable, 2.5m (8ft)

The 800G OSFP (IHS/Finned Top) to 2× 400G OSFP (IHS/Finned Top)-800G-DAC-2.5M8FT compatible cable combines 800G DAC connectivity with a defined 2.5m (8ft) pathway between 800G OSFP (IHS/Finned Top) to 2× 400G OSFP (IHS/Finned Top) interfaces. It is intended for Generic equipment and is documented here as a distinct order code, allowing cable schedules, service access and related length selections to be reviewed before installation.
OEM Part Number: 800G OSFP (IHS/Finned Top) to 2× 400G OSFP (IHS/Finned Top)-800G-DAC-2.5M8FTHT Part Number: 800G OSFP (IHS/Finned Top) to 2× 400G OSFP (IHS/Finned Top)-800G-DAC-2.5M8FT
Product Highlights
- HT-manufactured DAC assembly in 2.5m (8ft)
- 800G connectivity at 800Gbps
- Interface configuration: 800G OSFP (IHS/Finned Top) to 2× 400G OSFP (IHS/Finned Top)
- Fixed length and part number: 2.5m (8ft), 800G OSFP (IHS/Finned Top) to 2× 400G OSFP (IHS/Finned Top)-800G-DAC-2.5M8FT
- Cable construction: Passive Twinax
- Conductor specification: 26AWG
- Maximum power consumption: 0.1W (800G End)0.1W (400G Per End)
- Minimum bend radius: 45mm
Specifications
| HT Part Number | 800G OSFP (IHS/Finned Top) to 2× 400G OSFP (IHS/Finned Top)-800G-DAC-2.5M8FT |
|---|---|
| Manufacturer | HT |
| Form Factor | 800G OSFP (IHS/Finned Top) to 2× 400G OSFP (IHS/Finned Top) |
| Max. Data Rate | 800Gbps |
| Media | Copper |
| Cable Type | Passive Twinax |
| Minimum Bend Radius | 45mm |
| Max. Power Consumption | 0.1W (800G End)0.1W (400G Per End) |
| Cable Length | 2.5m (8ft) |
| Wire AWG | 26AWG |
| Commercial Temperature Range | 0 to 70°C (32 to 158°F) |
| Jacket Material | PVC |
| Protocols | OSFP MSA, IEEE 802.3ck, CMIS v4.0 |
| Modulation Format | 8x 100G PAM4 to Dual 4x 100G PAM4 |
Signal and Lane Configuration
The listed modulation format is 8x 100G PAM4 to Dual 4x 100G PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.
Power and Thermal Planning
The rated power consumption is 0.1W (800G End)0.1W (400G Per End). Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
Cable Construction and Routing
This assembly uses 26AWG conductors, PVC jacket, minimum bend radius 45mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
Network and Protocol Considerations
The intended application is determined by the host interface and protocol support. Listed interface and protocol references include OSFP MSA, IEEE 802.3ck, CMIS v4.0. Confirm that the host firmware and port configuration support the same operating mode.
Breakout Port Mapping
The 800G OSFP (IHS/Finned Top) to 2× 400G OSFP (IHS/Finned Top) configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.
Passive Copper Operation
A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.
Length Selection and Installation Planning
The 2.5m (8ft) version is useful when a two-metre run would leave insufficient working slack. Before installation, check the complete horizontal and vertical path so that 800G OSFP (IHS/Finned Top) to 2× 400G OSFP (IHS/Finned Top)-800G-DAC-2.5M8FT reaches both ports without tension at either connector.
Position Within the Length Range
800G OSFP (IHS/Finned Top) to 2× 400G OSFP (IHS/Finned Top)-800G-DAC-2.5M8FT occupies the middle of this family between 800G OSFP (IHS/Finned Top) to 2× 400G OSFP (IHS/Finned Top)-800G-DAC-2M7FT at 2m (7ft) and 800G OSFP (IHS/Finned Top) to 2× 400G OSFP (IHS/Finned Top)-800G-DAC-3M10FT at 3m (10ft). It adds 0.5m over the shorter option for extra routing clearance, while the next longer version adds another 0.5m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.
Structured Pathways and Serviceability
Treat the direct-attach assembly as part of the permanent pathway plan even when the link is expected to be temporary. Follow the intended horizontal and vertical managers, maintain the specified bend radius and leave service access around both ports. A small, supported service allowance is preferable to excess slack concealed inside a rack or placed under cable-tie pressure. For this assembly, the listed conductor specification is 26AWG; the minimum bend radius is 45mm; the stated power consumption is 0.1W (800G End)0.1W (400G Per End); the jacket material is PVC.
Ordering Information
Include the part number, fixed length, quantity and required pathway or rack grouping in the order information. The host model and firmware release are useful for change-controlled deployments. Different lengths should remain separate order lines so delivered labels and packing records agree with the pathway plan. Keep 800G OSFP (IHS/Finned Top) to 2× 400G OSFP (IHS/Finned Top)-800G-DAC-2.5M8FT associated with 2.5m (8ft) throughout the order and receiving record.
Generic Compatibility and Factory Testing
Verification covers the physical connectors, expected host identity and an operating link with available diagnostic indications. We distinguish this complete check from a simple continuity test. Platform model and software release can be reviewed in advance where the installation has strict documentation or change-control requirements. Both connectors are examined before the operating test, which includes link stability and diagnostic indications.
Shipping and Lead Time
Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. Delivery can be arranged by courier, air freight or sea freight, and goods may instead be handed to an appointed forwarder or shipped on the customer’s courier account.
Quality Assurance and Packaging
After connector inspection and link verification, the assembly is coiled without tight bends and packed with end protection. Labels can cross-reference the customer cable schedule, OEM part number and length. This supports both receiving checks and later moves, adds or changes. Volume orders can include customer references on the labels and carton list.
Frequently Asked Questions
Is this an original equipment manufacturer cable?
No. It is manufactured by HT under our own manufacturer identity.
Can excess cable be folded into a compact bundle?
No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.
Will any matching connector operate at the same speed?
Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.
What details assist a compatibility review?
Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.
Generic 800G DAC