You are here Transceivers AEC-Q56DD-400G-3M

Dell AEC-Q56DD-400G-3M Compatible 400G QSFP-DD 8 x 50G PAM4 Active Electrical Cable, 3m (10ft)

Dell AEC-Q56DD-400G-3M Compatible 400G QSFP-DD 8 x 50G PAM4 Active Electrical Cable, 3m (10ft)

This page covers one precise cable-schedule item: Dell AEC-Q56DD-400G-3M in 3m (10ft), supporting 400G operation through QSFP-DD to QSFP-DD. The complete AEC assembly is identified separately from other lengths and includes verified specifications, change-control-friendly ordering details and live-link factory checks.

OEM Part Number: AEC-Q56DD-400G-3MHT Part Number: AEC-Q56DD-400G-3M

Product Highlights

  • Compatible alternative to Dell AEC-Q56DD-400G-3M
  • 400G connectivity at 400Gbps
  • Interface configuration: QSFP-DD to QSFP-DD
  • Fixed length and part number: 3m (10ft), AEC-Q56DD-400G-3M
  • Cable construction: Active DAC (AEC)
  • Conductor specification: 32AWG
  • Maximum power consumption: 10W Per End
  • Minimum bend radius: 26.5mm

Specifications

HT Part NumberAEC-Q56DD-400G-3M
Dell CompatibleAEC-Q56DD-400G-3M
ManufacturerHT
Form FactorQSFP-DD to QSFP-DD
Max. Data Rate400Gbps
MediaCopper
Cable TypeActive DAC (AEC)
Minimum Bend Radius26.5mm
Wire AWG32AWG
Cable Length3m (10ft)
Jacket MaterialPET
Max. Power Consumption10W Per End
Modulation Format8x 50G-PAM4
DDM/DOMSupported
Commercial Temperature Range0 to 70°C (32 to 158°F)
ProtocolsQSFP-DD MSA, IEEE 802.3cd, CMIS 5.0

Signal and Lane Configuration

The listed modulation format is 8x 50G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Length Selection and Installation Planning

At 3m (10ft), this assembly can bridge non-aligned ports or adjacent racks while remaining a single direct-attach link. Support longer horizontal runs with suitable cable management and preserve space for cooling and future maintenance.

Position Within the Length Range

AEC-Q56DD-400G-3M occupies the middle of this family between AEC-Q56DD-400G-2M at 2m (7ft) and AEC-Q56DD-400G-5M at 5m (16ft). It adds 1m over the shorter option for extra routing clearance, while the next longer version adds another 2m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.

Structured Pathways and Serviceability

Treat the direct-attach assembly as part of the permanent pathway plan even when the link is expected to be temporary. Follow the intended horizontal and vertical managers, maintain the specified bend radius and leave service access around both ports. A small, supported service allowance is preferable to excess slack concealed inside a rack or placed under cable-tie pressure. For this assembly, the listed conductor specification is 32AWG; the minimum bend radius is 26.5mm; the stated power consumption is 10W Per End; the jacket material is PET.

Power and Thermal Planning

The rated power consumption is 10W Per End. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Cable Construction and Routing

This assembly uses 32AWG conductors, PET jacket, minimum bend radius 26.5mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is determined by the host interface and protocol support. Listed interface and protocol references include QSFP-DD MSA, IEEE 802.3cd, CMIS 5.0. Confirm that the host firmware and port configuration support the same operating mode.

Ordering Information

Include the part number, fixed length, quantity and required pathway or rack grouping in the order information. The host model and firmware release are useful for change-controlled deployments. Different lengths should remain separate order lines so delivered labels and packing records agree with the pathway plan. Quantity and any labeling instructions should be attached specifically to AEC-Q56DD-400G-3M.

Dell Compatibility and Factory Testing

Verification covers the physical connectors, expected host identity and an operating link with available diagnostic indications. We distinguish this complete check from a simple continuity test. Platform model and software release can be reviewed in advance where the installation has strict documentation or change-control requirements. Where supported by the host, link stability and diagnostic indications are reviewed together with the established link.

Shipping and Lead Time

Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. Worldwide courier services are available, with air or sea freight for consolidated shipments; freight-collect delivery and coordination with a customer’s logistics provider can be arranged.

Quality Assurance and Packaging

After connector inspection and link verification, the assembly is coiled without tight bends and packed with end protection. Labels can cross-reference the customer cable schedule, OEM part number and length. This supports both receiving checks and later moves, adds or changes. Volume orders can include customer references on the labels and carton list.

Frequently Asked Questions

Is this an original Dell cable?

No. It is an HT-manufactured compatible alternative for equipment that specifies Dell AEC-Q56DD-400G-3M.

Are separate transceivers or patch leads required?

No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.

Can excess cable be folded into a compact bundle?

No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.

Will any matching connector operate at the same speed?

Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.

New Zealand Fiber Optics

New Zealand Fiber Optics

New Zealand Service center: New Zealand 0632, Auckland.

Factory in Asia: Shangxue Industrial Area, Shenzhen

Product Datasheets

For PDF documents of products data sheet or any general inquiry, email info@huihongfiber.com and we will send you the details.

Customer Support

For customer support, please email sales@huihongfiber.com; our Auckland service team will respond promptly.