NETGEAR AVM762 Compatible 25G SFP28 LR-S Transceiver Module

NETGEAR AVM762 Compatible 25G SFP28 LR-S Transceiver Module

Built for hosts recognizing AVM762, this HT-manufactured SFP28 module delivers 25G transmission at 1310nm. Its rated reach is 300m, with Duplex LC as the physical interface. The specifications and engineering guidance below support structured fiber installations preserve a documented and serviceable optical channel, while keeping HT manufacture separate from the OEM cross-reference.

OEM Part Number: AVM762HT Part Number: SFP-25GLRS-31

Product Highlights

  • Compatible alternative to NETGEAR AVM762
  • 25G connectivity at 25.78125Gb/s
  • Optical wavelength: 1310nm
  • Specified reach: 300m
  • Duplex LC / SMF interface
  • Operating temperature: 0 to 70°C (32 to 158°F)
  • Factory compatibility verification and optical performance testing before shipment

Specifications

NETGEAR CompatibleAVM762
ManufacturerHT
HT Part NumberSFP-25GLRS-31
Form FactorSFP28
Max Data Rate25.78125Gb/s
Wavelength1310nm
Max Cable Distance300m
ConnectorDuplex LC
MediaSMF
Transmitter TypeDFB
Receiver TypePIN
TX Power-5~2dBm
Receiver Sensitivity<-8.5dBm
Power Budget3.5W
ModulationNRZ
Power Consumption1W
Extinction Ratio3W
CDRSupported
FEC FunctionSupported
Temperature Range0 to 70°C (32 to 158°F)
ProtocolsSFF-8472, SFF-8024, SFF-8431, SFF-8432, IEEE 802.3 by, IEEE 802.3cc
DOMSupported
Application25G Ethernet/ Data Center

Applications and Optical Link Design

Use this module for equipment interconnection over the specified single-mode fiber plant, including enterprise backbone, campus, metro or data-center interconnect links according to its rated distance. Confirm that both ends use the same optical standard and wavelength plan, and allow for connector, splice and patch-panel loss within the stated power budget.

Before deployment, check the host port type, supported data rate and firmware requirements. The 25G interface configuration must match the remote equipment; sharing a SFP28 housing alone does not make two transceiver types interoperable.

The single-mode link budget should include fiber attenuation, connectors, splices and panels over the intended 300m route. Keep the Duplex LC interface clean and match the remote optical standard. Consider receiver overload as well as insufficient power on short links.

NETGEAR Compatibility and Factory Testing

The module is checked for host recognition as AVM762, link establishment and diagnostic reporting. Physical cage fit alone is not treated as evidence of compatibility. Equipment model, hardware revision and software release can be reviewed before dispatch where platform behavior is uncertain.

Optical Acceptance, Diagnostics and Handling

For this model, the specified transmit-power range is -5~2dBm; receiver sensitivity is <-8.5dBm; the stated optical power budget is 3.5W. During commissioning, record the host diagnostic readings after the link has stabilized and compare them with those limits. DOM values are useful operational indicators, but they do not replace calibrated optical measurements when a link is marginal. Investigate unexpected loss through connector inspection, cleaning and a channel measurement before replacing the module. Diagnostic monitoring is listed as Supported. Before every insertion, keep dust caps in place until the patch lead is ready, avoid touching the optical end face and use an appropriate inspection and cleaning procedure. Do not look into an active optical interface.

Structured Fiber Pathways and Serviceability

Treat the transceiver as part of the complete channel. Follow the intended patch-panel route, maintain bend control and leave service access around the port. Confirm connector polish and fiber type at every mated pair; a documented service allowance is preferable to excess slack concealed inside a rack. For this model, the principal parameters are data rate 25.78125Gb/s, wavelength 1310nm, rated reach 300m.

Ordering Information

When ordering, specify AVM762, SFP-25GLRS-31, quantity and intended host platform. Project labels can repeat these details for receiving and asset records. Neutral labels, customer packaging and project-specific compatibility review are available on request.

Shipping and Lead Time

Standard configurations normally ship within one to three working days, with production lead times confirmed for larger quantities. International courier, air freight and sea freight are available; customer courier accounts and nominated forwarders are accepted.

Quality Assurance and Packaging

Quality control covers the optical or electrical interface, host identification and operating link. The verified unit is then individually protected and cartoned. Customer references, rack groups and project packing lists can be added for volume orders.

Frequently Asked Questions

Is this an original NETGEAR transceiver?

No. It is an HT-manufactured compatible alternative for equipment that specifies AVM762, not an original NETGEAR-branded module.

Which fiber and connector are required?

Use Duplex LC with SMF. The specified maximum reach is 300m, subject to fiber quality and total link loss.

Can it be mixed with another wavelength or reach version?

Only when the two ends share the same optical standard, wavelength plan and supported data rate. Check the exact part numbers and link budget rather than relying only on the module form factor.

New Zealand Fiber Optics

New Zealand Fiber Optics

New Zealand Service center: New Zealand 0632, Auckland.

Factory in Asia: Shangxue Industrial Area, Shenzhen

Product Datasheets

For PDF documents of products data sheet or any general inquiry, email info@huihongfiber.com and we will send you the details.

Customer Support

For customer support, please email sales@huihongfiber.com; our Auckland service team will respond promptly.