Arista C-Z100-2S50-3M Compatible 100G SFP-DD 2 x 50G PAM4 to 2 x SFP56 50G PAM4 Passive Copper Twinax Cable, 3m (10ft)

The C-Z100-2S50-3M compatible cable combines 100G DAC connectivity with a defined 3m (10ft) pathway between SFP-DD to 2x SFP56 interfaces. It is intended for Arista equipment and is documented here as a distinct order code, allowing cable schedules, service access and related length selections to be reviewed before installation.
OEM Part Number: C-Z100-2S50-3MHT Part Number: C-Z100-2S50-3M
Product Highlights
- Compatible alternative to Arista C-Z100-2S50-3M
- 100G connectivity at 100Gbps
- Interface configuration: SFP-DD to 2x SFP56
- Fixed length and part number: 3m (10ft), C-Z100-2S50-3M
- Cable construction: Passive Twinax
- Conductor specification: 26AWG
- Maximum power consumption: 0.1W
- Minimum bend radius: 28.8mm
Specifications
| HT Part Number | C-Z100-2S50-3M |
|---|---|
| Arista Compatible | C-Z100-2S50-3M |
| Manufacturer | HT |
| Form Factor | SFP-DD to 2x SFP56 |
| Max. Data Rate | 100Gbps |
| Media | Copper |
| Cable Type | Passive Twinax |
| Cable Length | 3m (10ft) |
| Jacket Material | PVC (OFNR) |
| Minimum Bend Radius | 28.8mm |
| Wire AWG | 26AWG |
| Max. Power Consumption | 0.1W |
| Modulation Format | SFP-DD-2x 50G-PAM4SFP56-1x 50G-PAM4 |
| Commercial Temperature Range | 0 to 70°C (32 to 158°F) |
| Application | 100G Ethernet, 128G Fibre Channel |
| Protocols | SFPDD: SFP-DD MSA, SFP-DD MIS, IEEE 802.3cdSFP56: SFF-8432, SFF-8402, SFF-8472, IEEE 802.3cd |
Signal and Lane Configuration
The listed modulation format is SFP-DD-2x 50G-PAM4SFP56-1x 50G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.
Length Selection and Installation Planning
At 3m (10ft), this assembly can bridge non-aligned ports or adjacent racks while remaining a single direct-attach link. Support longer horizontal runs with suitable cable management and preserve space for cooling and future maintenance.
Position Within the Length Range
C-Z100-2S50-3M is the longest of 3 verified length options in this family. Compared with C-Z100-2S50-2M at 2m (7ft), it provides 1m of additional reach for a longer vertical drop, a wider rack or an adjacent-cabinet route. Confirm that the complete path requires this length, because unused slack still needs supported, bend-safe storage.
Structured Pathways and Serviceability
Treat the direct-attach assembly as part of the permanent pathway plan even when the link is expected to be temporary. Follow the intended horizontal and vertical managers, maintain the specified bend radius and leave service access around both ports. A small, supported service allowance is preferable to excess slack concealed inside a rack or placed under cable-tie pressure. For this assembly, the listed conductor specification is 26AWG; the minimum bend radius is 28.8mm; the stated power consumption is 0.1W; the jacket material is PVC (OFNR).
Power and Thermal Planning
The rated power consumption is 0.1W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
Cable Construction and Routing
This assembly uses 26AWG conductors, PVC (OFNR) jacket, minimum bend radius 28.8mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
Network and Protocol Considerations
The intended application is 100G Ethernet, 128G Fibre Channel. Listed interface and protocol references include SFPDD: SFP-DD MSA, SFP-DD MIS, IEEE 802.3cdSFP56: SFF-8432, SFF-8402, SFF-8472, IEEE 802.3cd. Confirm that the host firmware and port configuration support the same operating mode.
Breakout Port Mapping
The SFP-DD to 2x SFP56 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.
Passive Copper Operation
A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.
Ordering Information
Include the part number, fixed length, quantity and required pathway or rack grouping in the order information. The host model and firmware release are useful for change-controlled deployments. Different lengths should remain separate order lines so delivered labels and packing records agree with the pathway plan. Quantity and any labeling instructions should be attached specifically to C-Z100-2S50-3M.
Arista Compatibility and Factory Testing
Verification covers the physical connectors, expected host identity and an operating link with available diagnostic indications. We distinguish this complete check from a simple continuity test. Platform model and software release can be reviewed in advance where the installation has strict documentation or change-control requirements. Both connectors are examined before the operating test, which includes link stability and diagnostic indications.
Shipping and Lead Time
Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. International express, air cargo and sea freight can be selected according to destination and carton volume; customer courier accounts and nominated forwarders are also accepted.
Quality Assurance and Packaging
After connector inspection and link verification, the assembly is coiled without tight bends and packed with end protection. Labels can cross-reference the customer cable schedule, OEM part number and length. This supports both receiving checks and later moves, adds or changes. Neutral packaging and customer-specific packing documentation are available on request.
Frequently Asked Questions
Is this an original Arista cable?
No. It is an HT-manufactured compatible alternative for equipment that specifies Arista C-Z100-2S50-3M.
Will any matching connector operate at the same speed?
Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.
What details assist a compatibility review?
Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.
How should an unused assembly be stored?
Protect both connector ends, keep the cable in a loose bend-safe coil and retain its part-number label so the length and compatibility identity remain traceable.
C-Z100-2S50-3M