You are here Transceivers 10/100BASE-T SFP

Generic Cable Series Compatible 50G SFP56 Active Copper Twinax Cable

Generic Cable Series Compatible 50G SFP56 Active Copper Twinax Cable

The Cable Series compatible series is designed for Generic hosts requiring a 50G ACC connection. Its SFP56 arrangement is supplied as an active copper assembly with the cable and signal-conditioning interfaces supplied together. Use the specifications to assess the physical assembly, then follow the exact length and part-number links when preparing a bill of materials or requesting a compatibility check.

Series Part Number: Cable SeriesHT Part Number: Cable Series

Product Highlights

  • HT-manufactured compatible alternative for Generic Cable Series
  • 50G aggregate connectivity at 50Gbps
  • Interface configuration: SFP56
  • Active Twinax
  • Length configurations covered: 1m (3ft), 2m (7ft), 3m (10ft), 5m (16ft) and 7m (23ft)
  • Conductor specification: 30AWG
  • Power consumption: ≤0.5W
  • Operating temperature: 0 to 70°C (32 to 158°F)

Available Lengths and Corresponding Part Numbers

The documented configurations are 1m (3ft), 2m (7ft), 3m (10ft), 5m (16ft) and 7m (23ft). Each link below opens the separate product page for that physical length and its corresponding OEM part number. Select the exact assembly required by the route and purchase order; custom project lengths can be discussed separately.

Compatible OEM Part Numbers

  • Cable Series-1M3FT
  • SFP56-50G-ACC-2M7FT
  • SFP56-50G-ACC-3M10FT
  • SFP56-50G-ACC-5M16FT
  • SFP56-50G-ACC-7M23FT
  • Cable Series

Specifications

CompatibleGeneric
ManufacturerHT
HT Part NumberCable Series
Form FactorSFP56
Max Data Rate50Gbps
Cable TypeActive Twinax
Max Cable DistanceUp to 7m
Cable Length Options Covered1m (3ft), 2m (7ft), 3m (10ft), 5m (16ft) and 7m (23ft)
Wire AWG30AWG
Power Consumption≤0.5W
Jacket MaterialPVC
Storage Temperature-40 to 85°C (-40 to 185°F)
Operating Temperature0 to 70°C (32 to 158°F)
Modulation TechnologyPAM4
Bit Rate53.125 Gbps
ProtocolSFP56 MSA

Applications and Deployment

Active copper assemblies add signal conditioning while retaining the convenience of a direct-attached cable. They are appropriate where the equipment supports the stated active-cable type and the route exceeds the practical limits of a comparable passive assembly. Per-end power, airflow and host qualification should be assessed before high-density deployment. For this series, the listed interface is SFP56 and the aggregate rate is 50G.

Generic Compatibility and Factory Testing

Verification covers the physical connectors, expected host identity and an operating link with available diagnostic indications. We distinguish this complete check from a simple continuity test. Platform model and software release can be reviewed in advance where the installation has strict documentation or change-control requirements. Series-level inspection is followed by the exact length and OEM configuration selected for dispatch. Functional verification includes link establishment and diagnostic indications where the host exposes them.

Cable Construction and Routing

The specification table records the conductor specification is 30AWG; the jacket material is PVC; the operating temperature is 0 to 70°C (32 to 158°F); the power consumption is ≤0.5W. Use those values when preparing the rack pathway and receiving checklist. Do not pull a connector by its cable, compress the run under tight ties or force excess length into a sharp coil. Connector protection should remain in place until the assembly is ready for insertion.

Structured Pathways and Serviceability

Treat the direct-attach assembly as part of the permanent pathway plan even when the link is expected to be temporary. Follow the intended horizontal and vertical managers, maintain the specified bend radius and leave service access around both ports. A small, supported service allowance is preferable to excess slack concealed inside a rack or placed under cable-tie pressure. For this series, keep the interface rate, ACC construction and length-specific OEM reference together throughout that review.

Ordering Information

Include the part number, fixed length, quantity and required pathway or rack grouping in the order information. The host model and firmware release are useful for change-controlled deployments. Different lengths should remain separate order lines so delivered labels and packing records agree with the pathway plan. For this series, follow the corresponding length link, quote that exact OEM part number and keep different lengths on separate order lines. HT part number Cable Series identifies the product family; the linked page provides the final length-specific identity.

Shipping and Lead Time

Standard configurations normally ship within one to three working days, with production lead times confirmed for larger quantities. International courier, air freight and sea freight are available; customer courier accounts and nominated forwarders are accepted.

Quality Assurance and Packaging

After connector inspection and link verification, the assembly is coiled without tight bends and packed with end protection. Labels can cross-reference the customer cable schedule, OEM part number and length. This supports both receiving checks and later moves, adds or changes. Both connector ends are inspected as part of the complete assembly, and protective packing is selected to avoid tight bends during transport and storage.

Frequently Asked Questions

Is this an original Generic cable?

No. It is an HT-manufactured compatible cable for equipment that specifies Cable Series, not an original Generic-branded product.

Are different lengths and OEM part numbers separate products?

Yes. Where a length has its own OEM reference, follow the corresponding link above and order that exact part number on its own line. Do not substitute another length only because the connector arrangement is the same.

Does this ACC cable require separate modules at each end?

No. The connector ends and cable form one complete direct-attach assembly. The ends are not detachable standalone transceivers, and the complete product is tested together.

What information helps confirm compatibility?

Provide the equipment manufacturer and model, port type, hardware revision and software release, together with the required OEM reference, length and quantity. Breakout projects should also identify the intended lane configuration.

New Zealand Fiber Optics

New Zealand Fiber Optics

New Zealand Service center: New Zealand 0632, Auckland.

Factory in Asia: Shangxue Industrial Area, Shenzhen

Product Datasheets

For PDF documents of products data sheet or any general inquiry, email info@huihongfiber.com and we will send you the details.

Customer Support

For customer support, please email sales@huihongfiber.com; our Auckland service team will respond promptly.