Customized 4-24 Fibers OM4 LC/SC/FC/ST/LSH Fiber Optic Pigtail

New Zealand engineering teams can use the documented values below to compare the product with the intended channel and as-built requirements. This made-to-order pigtail platform is built to the ordered design: OM4 fiber mode, connector product line, polish, jacket rating and length are all confirmed before production is released. Each leg is factory terminated, polished and optically tested; therefore, the splice point inherits a connector end face that field polishing cannot match.
Product Highlights
- Optical Testing Guarantees Insertion Loss and Returns Loss
- Individually Colored to Easily Match Color-coded Fiber Cable That Will Be Spliced
- Easy-strip Tight-buffered Coating
- Available in PVC (Unrated)/Riser (OFNR)/LSZH/Plenum (OFNP) Cable Jacket
- Available in LC, SC, FC, ST, LSH Connectors
Specifications
| Connector A | LC/SC/FC/ST/LSH UPC Simplex |
|---|---|
| Connector B | Unterminated |
| Fiber Count | 4/6/8/12/24 Fibers |
| Fiber Grade | Bend Insensitive |
| Fiber Mode | OM4 50/125μm |
| Wavelength | 850/1300nm |
| Breakout Length | 0.3/0.5m |
| Cable Jacket | 0.9mm: PVC (Unrated)/LSZH |
| Min. Bend Radius (Optical Fiber) | 7.5mm |
| Min. Bend Radius (Bunch/Ribbon) | 20/10D (Dynamic/Static) |
| Connector Durability | 1000 Times |
| Attenuation at 850nm | 3.0dB/km |
| Attenuation at 1300nm | 1.0dB/km |
| Insertion Loss | ≤0.3dB |
| Return Loss | ≥20dB |
| Operating Temperature | Plenum (OFNP): -10 to 60°C (14 to 140°F) |
| Storage Temperature | Plenum (OFNP): -10 to 70°C (14 to 158°F) |
| Connector Type | LC/SC/FC/ST/LSH UPC Simplex to Unterminated |
Why pigtails remain the standard termination
A pigtail is half a joint: one end is a factory-finished connector, polished and tested under practice control; the other is a bare fiber strand ready for the splice. Fusion-splicing that strand onto the fitted cable brings the relevant connector quality of the factory to a field channel. The result outperforms field-polished connectors on insertion loss, return loss and long-term stability, and it outperforms pre-terminated trunks when the channel length is uncertain or the pathway is difficult to pre-measure.
Fusion splicing practice that protects the budget
A good splice starts long before the splicer arcs: strip the strand cleanly, cleave square, keep the sleeve staged, and protect the completed splice in the tray with the bend radius respected. The tight-buffered 0.9mm coating on this pigtail strips in one motion and seats cleanly in standard splice sleeves. Done well, a fusion splice adds less attenuation than a connector pair and stays stable for the life of the plant. New Zealand project teams can retain this information with the as-built documentation for later review.
Ordering a customized pigtail platform
The made-to-order platform turns a catalog of options into one ordered design: connector product line from LC, SC, FC, ST and LSH; polish as UPC or APC; jacket rating to suit the channel; length to the measured run; and fiber count where the platform offers it. State the combination with the enquiry and the factory confirms the manufacturable specification before production is released. The delivered pigtail then matches the relevant panel hardware, the tray geometry and the channel without field improvisation.
Configuration choices that matter at the tray
Three choices decide how a made-to-order pigtail behaves at the splice point: the relevant connector product line must be compatible with the relevant panel adapters, the polish discipline must be compatible with the plant - mixing UPC and APC at one mating point destroys return loss - and the jacket rating must satisfy the pathway code. Getting these right at order time is faster than any field correction, and the factory test report then applies to the particular delivered design.
Choosing the fiber mode for the plant
Single-mode OS2 serves long links, PON access and any plant where distance or wavelength plans matter; the bend-insensitive glass grade keeps attenuation stable in dense trays. OM3 and OM4 multimode serve hardware rooms and data halls where transceiver cost favors short-reach optics. OM1 and OM2 remain in service in legacy plants and must be matched like-for-like. The pigtail mode must equal the relevant cable plant mode - a mismatch splices poorly and performs worse.
Bend-insensitive glass in dense trays
Splice trays and panel rear spaces punish fiber: tight routing, crowded dressing and the occasional hurried re-entry all bend strands beyond what legacy single-mode tolerated. The bend-insensitive grade used in this pigtail holds attenuation stable at bend radii that would fog conventional glass, which keeps the optical path margin intact after the tenth tray opening, not just at commissioning.
A splicing workflow that scales
Productive termination crews work to a fixed routine: mount the tray, dress the relevant cable, splice the pigtails color by color, protect every joint, test every completed port, then close and label. With the routine fixed, a two-person crew terminates a full frame mounting point in a predictable time, and the test record maps cleanly onto the documentation. The consistency additionally makes quality auditable - matching materials, matching sequence, matching pass criteria across each site.
Sparing and kit planning for termination work
Pigtails belong in the termination kit in counted sets with spares: strands break, connectors get contaminated beyond recovery, and a missing spare converts a ten-minute task into a second visit. Plan one spare set per frame mounting point, keep spare strands capped and bagged, and record which set went into which tray so replacement stock can be ordered to the identical specification.
Selecting the right pigtail for the job
Five decisions define the order: the relevant connector product line must be compatible with the relevant panel, the polish must be compatible with the plant, the fiber mode must be compatible with the relevant cable, the design must be compatible with the channel, and the count must be compatible with the tray capacity. Getting all five right at order time is what turns a box of strands into a dependable termination. Where the requirement sits outside the standard configurations, the made-to-order platforms cover the remaining combinations.
Optical Testing and Quality Checks
Each pigtail is optically tested before packing: insertion loss and return loss are verified on every terminated leg, and the ferrule end faces are inspected for scratches and contamination. The strands ship coiled, capped and bagged, with the test results offered on specify.
How to Specify and Order
Refer to this pigtail by connector, polish, fiber mode, fiber count and design when requisitioning a quotation. For configurations outside the listed options - mixed connector families, jacket ratings, lengths or project packing - send the requirement with the enquiry and the factory will cross-check the manufacturable specification. New Zealand project orders can include documentation and labeling requirements alongside the technical configuration.
10/100BASE-T SFP