Juniper Networks JNP-QSFP-DACBO-7MA Compatible 40G QSFP+ to 4 x 10G SFP+ Active Copper Breakout Cable, 7m (23ft)

Juniper Networks JNP-QSFP-DACBO-7MA Compatible 40G QSFP+ to 4 x 10G SFP+ Active Copper Breakout Cable, 7m (23ft)

For structured equipment cabling that specifies Juniper Networks JNP-QSFP-DACBO-7MA, this 7m (23ft) assembly provides a complete 40G ACC link. Its configuration is QSFP+ to SFP+. The page brings together mechanical specifications, pathway considerations and compatibility verification so the product can be incorporated into a serviceable installation plan.

OEM Part Number: JNP-QSFP-DACBO-7MAHT Part Number: JNP-QSFP-DACBO-7MA

Product Highlights

  • Compatible alternative to Juniper Networks JNP-QSFP-DACBO-7MA
  • 40G connectivity at 40Gbps
  • Interface configuration: QSFP+ to SFP+
  • Fixed length and part number: 7m (23ft), JNP-QSFP-DACBO-7MA
  • Cable construction: Active Twinax
  • Conductor specification: 26AWG
  • Maximum power consumption: ≤1.8W
  • Minimum bend radius: 44.5mm

Specifications

HT Part NumberJNP-QSFP-DACBO-7MA
Juniper CompatibleJNP-QSFP-DACBO-7MA
ManufacturerHT
Form FactorQSFP+ to SFP+
Max Data Rate40Gbps
MediaCopper
Cable TypeActive Twinax
Cable Length7m (23ft)
Wire AWG26AWG
Minimum Bend Radius44.5mm
Power Consumption≤1.8W
Jacket MaterialPVC (OFNR)
Commercial Temperature Range0 to 70°C (32 to 158°F)
ProtocolsSFF-8431, SFF-8432, SFF-8472 SFP+ MSA, SFF-8436 QSFP+ MSA

Juniper Deployment Reference

Juniper platform documentation distinguishes straight QSFP28 DAC or AOC connections from DACBO and AOCBO breakout operation. On channelized systems, the host port must be configured for the required breakout mode. Match this HT compatible cable to the exact Juniper part number and the intended platform configuration.

Power and Thermal Planning

The rated power consumption is ≤1.8W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Cable Construction and Routing

This assembly uses 26AWG conductors, PVC (OFNR) jacket, minimum bend radius 44.5mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is determined by the host interface and protocol support. Listed interface and protocol references include SFF-8431, SFF-8432, SFF-8472 SFP+ MSA, SFF-8436 QSFP+ MSA. Confirm that the host firmware and port configuration support the same operating mode.

Breakout Port Mapping

The QSFP+ to SFP+ configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.

Length Selection and Installation Planning

The installation review for a 7m (23ft) link should include pathway length, support points, connector access and future maintenance. Route the complete copper assembly and both connector housings before attaching both ends, and avoid dragging it across connector panels. A final inspection should confirm that no latch, boot or jacket section carries unnecessary strain. Within this family, JNP-QSFP-DACBO-5MA is shorter at 5m (16ft), while JNP-QSFP-DACBO-9MA is the next longer choice at 9m (29ft); comparing those two boundaries helps avoid both tension and unnecessary slack.

Position Within the Length Range

JNP-QSFP-DACBO-7MA occupies the middle of this family between JNP-QSFP-DACBO-5MA at 5m (16ft) and JNP-QSFP-DACBO-9MA at 9m (29ft). It adds 2m over the shorter option for extra routing clearance, while the next longer version adds another 2m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.

Structured Pathways and Serviceability

Treat the direct-attach assembly as part of the permanent pathway plan even when the link is expected to be temporary. Follow the intended horizontal and vertical managers, maintain the specified bend radius and leave service access around both ports. A small, supported service allowance is preferable to excess slack concealed inside a rack or placed under cable-tie pressure. For this assembly, the listed conductor specification is 26AWG; the minimum bend radius is 44.5mm; the stated power consumption is ≤1.8W; the jacket material is PVC (OFNR).

Ordering Information

Include the part number, fixed length, quantity and required pathway or rack grouping in the order information. The host model and firmware release are useful for change-controlled deployments. Different lengths should remain separate order lines so delivered labels and packing records agree with the pathway plan. Quantity and any labeling instructions should be attached specifically to JNP-QSFP-DACBO-7MA.

Juniper Networks Compatibility and Factory Testing

Verification covers the physical connectors, expected host identity and an operating link with available diagnostic indications. We distinguish this complete check from a simple continuity test. Platform model and software release can be reviewed in advance where the installation has strict documentation or change-control requirements. Where supported by the host, link stability and diagnostic indications are reviewed together with the established link.

Shipping and Lead Time

Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. Delivery can be arranged by courier, air freight or sea freight, and goods may instead be handed to an appointed forwarder or shipped on the customer’s courier account.

Quality Assurance and Packaging

After connector inspection and link verification, the assembly is coiled without tight bends and packed with end protection. Labels can cross-reference the customer cable schedule, OEM part number and length. This supports both receiving checks and later moves, adds or changes. Standard protective packing is used by default, with project documentation arranged when requested.

Frequently Asked Questions

Is this an original Juniper Networks cable?

No. It is an HT-manufactured compatible alternative for equipment that specifies Juniper Networks JNP-QSFP-DACBO-7MA.

Will any matching connector operate at the same speed?

Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.

What details assist a compatibility review?

Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.

How should an unused assembly be stored?

Protect both connector ends, keep the cable in a loose bend-safe coil and retain its part-number label so the length and compatibility identity remain traceable.

New Zealand Fiber Optics

New Zealand Fiber Optics

New Zealand Service center: New Zealand 0632, Auckland.

Factory in Asia: Shangxue Industrial Area, Shenzhen

Product Datasheets

For PDF documents of products data sheet or any general inquiry, email info@huihongfiber.com and we will send you the details.

Customer Support

For customer support, please email sales@huihongfiber.com; our Auckland service team will respond promptly.