LC/APC Single Mode Fixed Fiber Optic Attenuator, Male to Female, 1-25dB

LC/APC Single Mode Fixed Fiber Optic Attenuator, Male to Female, 1-25dB

New Zealand engineering teams can use the documented values below to compare the product with the intended channel and as-built requirements. LC/APC Single Mode Fixed Fiber Optic Attenuator inserts a precisely calibrated fixed loss into a fiber optical path. The attenuating element is ion-doped fiber - the loss is spectrally flat and reflection-free, unlike air-gap or offset designs - so the optical path sees exactly the rated attenuation at each operating wavelength. The male-to-female plug body attaches directly to the relevant panel adapter or transceiver port, adding attenuation without an extra patch cord in the optical route.

Product Highlights

  • 1260 to 1620nm Wavelength Singlemode Attenuators
  • Precision Polishing for Reduced Back Reflection
  • Standard Fixed Attenuation Values of 1dB up to 25dB
  • Applied for CWDM, DWDM, Test Equipment, CATV Systems, Point to Point Systems, etc.
  • Attenuating Material-ion Doped Fiber

Specifications

Fiber ConnectorLC/APC
Polish TypeAPC
Connector GenderFixed Male to Female
Attenuation1~25dB
Operating Wavelength(nm)1260~1620
Operating Temperature Range-25 to 70°C (-13 to 158°F)
Storage Temperature Range-40 to 85°C (-40 to 185°F)
Application(1)Matching Product(1)
Return Loss≥60dB (APC)

Available Attenuation Values

The LC/APC fixed attenuator is available across the full standard range: 1dB, 2dB, 3dB, 4dB, 5dB, 6dB, 7dB, 8dB, 9dB, 10dB, 11dB, 12dB, 13dB, 14dB, 15dB, 16dB, 17dB, 18dB, 19dB, 20dB, 21dB, 22dB, 23dB, 24dB, 25dB. Every value is individually calibrated at 1310 nm and 1550 nm and the rated figure is marked on each housing, so the ordered value is exactly the installed value. State the required figure - for example LC/APC 10dB - with the enquiry.

1dB   2dB   3dB   4dB   5dB   6dB   7dB   8dB   9dB   10dB   11dB   12dB   13dB   14dB   15dB   16dB   17dB   18dB   19dB   20dB   21dB   22dB   23dB   24dB   25dB

Attenuation in testing and calibration

Beyond live links, attenuators are the reference instruments of the fiber lab. Receiver sensitivity is measured by adding loss until errors appear; power meters are calibrated against known attenuation data; a new transceiver type is qualified across its receive range before implementation. Fixed attenuators provide the stable reference points, and variable attenuators sweep the range between them. The two must hold their rated specification over wavelength and temperature, which is what separates a calibrated device from a decorative one.

Spectral flatness across the operating band

An attenuator that reads 10 dB at 1310 nm but 12 dB at 1550 nm is a measurement error waiting to happen. The ion-doped element in these attenuators is engineered for spectral flatness across the full 1260 to 1620 nm window, covering each common operating wavelength from legacy 1310 nm links through DWDM C-band and L-band systems. One device therefore serves the whole plant instead of one wavelength plan.

Fixed values versus a variable instrument

Fixed attenuators win on stability, size and price: once the intended loss is known, a fixed device holds it permanently with no moving parts. Variable attenuators win when the loss itself is the question - receiver sensitivity testing, margin surveys, multi-wavelength leveling - where sweeping the specification is the whole point. Most plants need the two: fixed units fitted in the links, and a variable instrument in the test kit.

Choosing the attenuation value

The right specification is the difference between what the optical path delivers and what the receiver wants, plus a small margin. Measure or calculate the expected receive power first; then establish the nearest standard specification - 1, 2, 3, 5, 7, 10, 15, 20 or 25 dB - that lands the receiver inside its window. Too little attenuation leaves the receiver overloaded; too much eats the margin that aging and repairs will need later. When the requirement sits between standard data, the made-to-order platform covers the particular figure.

Male-to-female plug attenuators in practice

The plug-style body turns the attenuator into a connector accessory rather than a cable item: the male end seats directly in the relevant panel adapter or the transceiver port, and the established patch cord mates to the female end. No extra jumper, no extra mating pair, no extra loss beyond the rated specification. In dense frames this matters twice - once in the loss calculation, and once in the relevant cable management behind the relevant panel.

Return loss and the polish discipline

Because an attenuator sits in the middle of the optical path, its reflectance counts twice - once toward the transmitter and once toward the receiver. UPC versions hold return loss at 50 dB or better, and APC versions at 60 dB or better, which keeps reflected power far below anything a modern transmitter notices. The polish grade must be compatible with the plant: an APC attenuator mated to a UPC connector through an adapter damages the two end faces and destroys the very return loss it was chosen to protect.

Handling and cleaning attenuators

An attenuator is a connector with optics inside, and connector rules apply: keep the caps on until the moment of mating, clean each end face before insertion, and never mate a contaminated ferrule into the device - the dirt transfers to the attenuator end face and the next connector that touches it. Store spare units capped and bagged, and record which optical path every fitted unit serves so replacement orders match the original specification.

Selecting the right attenuator

Four decisions define the order: the attenuation specification must be compatible with the optical path calculation, the relevant connector product line must be compatible with the port or the patch leads, the polish grade must be compatible with the plant, and the body style - plug or inline - must suit the deployment. Fixed data cover permanent installations; the variable instruments cover testing; the test cable covers transceiver qualification. Getting all four right at order time is what turns a small component into a dependable part of the optical path.

Optical Testing and Quality Checks

Each attenuator is optically verified before packing: the attenuation specification is measured at the operating wavelengths and checked against its rated tolerance, return loss is verified to its polish grade, and the relevant connector end faces are inspected for scratches and contamination. Units ship capped and bagged.

How to Specify and Order

Refer to this attenuator by attenuation specification, connector product line, polish grade and body style when requisitioning a quotation. For data or configurations outside the listed options - non-standard dB figures, mixed connector pairings or project packing - send the requirement with the enquiry and the factory will cross-check the manufacturable specification. New Zealand project orders can include documentation and labeling requirements alongside the technical configuration.

New Zealand Fiber Optics

New Zealand Fiber Optics

New Zealand Service center: New Zealand 0632, Auckland.

Factory in Asia: Shangxue Industrial Area, Shenzhen

Product Datasheets

For PDF documents of products data sheet or any general inquiry, email info@huihongfiber.com and we will send you the details.

Customer Support

For customer support, please email sales@huihongfiber.com; our Auckland service team will respond promptly.