LC UPC to SC APC Simplex Armored Fiber Patch Cable, OS2, Riser (OFCR)

LC UPC to SC APC Simplex Armored Fiber Patch Cable, OS2, Riser (OFCR)

New Zealand engineering teams can use the documented values below to compare the product with the intended channel and as-built requirements. This hybrid simplex armored patch cable puts an LC UPC connector on one end and an SC APC connector on the other, joined by a single OS2 9/125µm fiber inside a helical stainless steel tube and blue 3.0mm riser-rated (OFCR) jacket. It is built for the common access-network case where the active hardware speaks LC but the optical distribution network presents an angled SC interface.

Product Highlights

  • Helical stainless steel armor against crush, impact and rodents
  • G.657.A1 bend-insensitive fiber, 10/5D bend radius
  • Riser (OFCR) flame rating for vertical building pathways
  • Stock lengths 1m to 30m; custom lengths and jackets on request
  • LC UPC to SC APC hybrid simplex, OS2 9/125µm single mode
  • Connects LC equipment directly to APC-terminated ODN plant

Specifications

Connector TypeLC to SC
Polish TypeUPC to APC
Fiber ModeOS2 9/125µm
Wavelength1310/1550nm
Fiber CountSimplex
Fiber GradeG.657.A1 (Compatible with G.652.D)
Min. Bend Radius (Fiber Cable)10/5D (Dynamic/Static)
Cable Outside Diameter (OD)3.0mm
Flame RatingRiser (OFCR)
Construction TypeSingle Armored, Stainless Steel Tube
Tensile Strength120/225N (Long/Short Term)
Insertion Loss≤0.3dB
Return Loss≥50dB (UPC) / ≥60dB (APC)
Operating Temperature-20 to 70°C (-4 to 158°F)
Storage Temperature-40 to 70°C (-40 to 158°F)

A hybrid cord between transceiver and ODN

FTTx and access deployments constantly bridge two interface worlds: the OLT, media converter or test set with LC ports on one side, and the distribution frame or wall outlet terminated with SC APC on the other. A hybrid cord makes that transition in one tested item instead of stacking an adapter onto a standard jumper, removing a mated pair and its loss from the optical path.

Mixed polish on one assembly, and why it matters

The UPC end is flat-polished for the relevant equipment side; the APC end is ground at 8 degrees to mate with the angled plant. UPC and APC connectors must never be mated to one another: the angled and flat end faces meet at a gap that destroys return loss and may chip the fiber. This cord is built so every end meets only the interface it was polished for.

Armored for the last exposed meters

Hybrid access tails run through the least controlled part of the network: customer wall boxes, cabinet doors, basement risers and pole-top enclosures. The helical steel tube inside the jacket gives the cord crush and rodent resistance exactly where the fixed plant may no longer protect it, without sleeving the run in conduit.

Typical applications for the hybrid build

The common three: connecting LC-port OLT or test hardware to an SC APC distribution frame, jumpering between an ONT with LC pigtail access and the APC wall outlet, and lab setups where LC-based instruments must exercise APC plant. In all three the hybrid cord replaces an adapter-plus-jumper stack, removing one mated pair from the optical path and one source of intermittent loss from the trouble report.

Length range and customization

Regular length versions are stocked for fast delivery: 1m (3ft), 2m (7ft), 3m (10ft), 5m (16ft), 10m (33ft), 15m (49ft), 20m (66ft) and 30m (98ft), covering the common rack-to-rack, access and frame connections this cord is built for. Project-built lengths beyond this range are manufactured to order. For access tails, measure from the relevant equipment port to the frame mounting point and order to that figure; the cord then dresses without a service loop trapped behind the enclosure. Specifying the particular channel length avoids the two the slack storage problem of an overlong cord and the strain risk of one that is too short.

Optical testing and quality checks

Each hybrid item is terminated with precision zirconia ferrules, with the APC end angle-verified and the two connection points geometry-checked. Insertion loss and return loss are measured through the finished cord before packing; therefore, the 0.3dB insertion ceiling and the 50/60dB return figures describe the delivered item, not a lab sample.

How to Specify and Order

Refer to the LC UPC to SC APC simplex armored product line when requisitioning a quotation, and state the channel length and jacket rating. If the plant uses a separate connector mix, the made-to-order simplex armored program builds any combination once the factory confirms the specification. New Zealand project orders can include documentation and labeling requirements alongside the technical configuration.

New Zealand Fiber Optics

New Zealand Fiber Optics

New Zealand Service center: New Zealand 0632, Auckland.

Factory in Asia: Shangxue Industrial Area, Shenzhen

Product Datasheets

For PDF documents of products data sheet or any general inquiry, email info@huihongfiber.com and we will send you the details.

Customer Support

For customer support, please email sales@huihongfiber.com; our Auckland service team will respond promptly.