LC UPC to SC UPC Duplex OM3 Fiber Patch Cable

New Zealand engineering teams can use the documented values below to compare the product with the intended channel and as-built requirements. This OM3 fiber patch cable carries a LC UPC interface on one end and a SC UPC interface on the other, factory terminated on OM3 glass and optically tested as a full item. The duplex zipcord design keeps the transmit and receive strands paired in one item for fast, error-free patching.
Product Highlights
- Bend Insensitive Fiber with 7.5mm Min. Bend Radius
- Precision Zirconia Ferrule Connectors Ensure Low Loss
- Flame-Retardant Riser (OFNR) for Vertical and Floor-to-Floor Installations
- Color-Coded Cable Jacket for Easy Identification
- Duplex Zipcord Construction Reduces Risk of Damage from Crimping
Specifications
| Connector A | LC UPC Duplex |
|---|---|
| Connector B | SC UPC Duplex |
| Fiber Count | 2 Fibers |
| Fiber Grade | Bend Insensitive Fiber |
| Fiber Mode | OM3 50/125μm |
| Wavelength | 850/1300nm |
| Flame Rating | Riser (OFNR) |
| Cable Outside Diameter (OD) | 2.0mm |
| Polarity | A (Tx) to B (Rx) |
| Cable Type | Tight-Buffered |
| Min. Bend Radius (Optical Fiber) | 7.5mm |
| Min. Bend Radius (Fiber Cable) | 20/10D (Dynamic/Static) |
| Connector Durability | 1000 times |
| Tensile Strength | 90/150N (Long/Short Term) |
| Insertion Loss | ≤0.3dB |
| Return Loss | ≥30dB |
| Attenuation at 850nm | ≤3.5dB/km |
| Attenuation at 1300nm | ≤1.5dB/km |
| Operating Temperature | -10 to 70°C (14 to 158℉) |
| Storage Temperature | -20 to 70°C (-4 to 158℉) |
Keeping multimode links healthy
Multimode links fail more typically from contamination than from fiber damage. Each ferrule should be inspected and cleaned before final connection, and the dust caps ought to stay on until the moment of joint. These habits matter more than any specification on the datasheet.
OM3 for existing multimode plants
This OM3 item matches the fitted base of OM3 optical path cabling: 10G links to 300 meters and 40/100G SR4 links to 70 meters. When the permanent optical path is OM3, patching with OM3 keeps the optical path specification homogeneous and the test reports clean.
Length Options
Regular length versions cover the common patching routes: 1m (3ft), 2m (7ft), 3m (10ft), 5m (16ft), 7m (23ft), 10m (33ft), 15m (49ft), with made-to-order length offered beyond the list. Specifying the measured channel length keeps the slack out of the manager and the strain off the connection interfaces.
Quality Control and Testing
Each optical assembly is terminated with precision zirconia ferrule connectors and optically tested before packing: insertion loss and return loss are verified on every cable, and end-face geometry is inspected for consistent physical contact. The relevant cable ships with dust caps on the two connectors and the test result offered on specify.
Ordering and Factory Support
Refer to this design by connector pair, fiber mode and length when requisitioning a quotation. For configurations outside the listed options, mixed connector families, jackets, identification or project packing, send the requirement with the enquiry and the factory will cross-check the build before production is released. New Zealand project orders can include documentation and labeling requirements alongside the technical configuration.