NVIDIA/Mellanox MCA4J80-N004 Compatible 800G Twin-port OSFP 8 x 100G PAM4 IHS/Finned Top InfiniBand NDR Active Copper Twinax Cable, 4m (13ft)

For structured equipment cabling that specifies NVIDIA/Mellanox MCA4J80-N004, this 4m (13ft) assembly provides a complete 800G ACC link. Its configuration is OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top). The page brings together mechanical specifications, pathway considerations and compatibility verification so the product can be incorporated into a serviceable installation plan.
OEM Part Number: MCA4J80-N004HT Part Number: MCA4J80-N004
Product Highlights
- Compatible alternative to NVIDIA/Mellanox MCA4J80-N004
- 800G connectivity at 850Gbps (8x 106.25Gbps)
- Interface configuration: OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)
- Fixed length and part number: 4m (13ft), MCA4J80-N004
- Cable construction: Active DAC (ACC)
- Conductor specification: 26AWG
- Maximum power consumption: 1.3W Per End
- Minimum bend radius: 59.5mm
Specifications
| HT Part Number | MCA4J80-N004 |
|---|---|
| NVIDIA/Mellanox InfiniBand Compatible | MCA4J80-N004 |
| Manufacturer | HT |
| Form Factor | OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top) |
| Max. Data Rate | 850Gbps (8x 106.25Gbps) |
| Media | Copper |
| Cable Type | Active DAC (ACC) |
| Cable Length | 4m (13ft) |
| Wire AWG | 26AWG |
| Minimum Bend Radius | 59.5mm |
| Max. Power Consumption | 1.3W Per End |
| Jacket Material | PET |
| Commercial Temperature Range | 0 to 70°C (32 to 158°F) |
| Modulation Format | 8x100G-PAM4 |
| Application | 800G InfiniBand |
| Protocols | CMIS 5.0, IEEE 802.3ck, OSFP Rev5.0 |
Signal and Lane Configuration
The listed modulation format is 8x100G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.
Power and Thermal Planning
The rated power consumption is 1.3W Per End. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
Cable Construction and Routing
This assembly uses 26AWG conductors, PET jacket, minimum bend radius 59.5mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
Network and Protocol Considerations
The intended application is 800G InfiniBand. Listed interface and protocol references include CMIS 5.0, IEEE 802.3ck, OSFP Rev5.0. Confirm that the host firmware and port configuration support the same operating mode.
Length Selection and Installation Planning
The 4m (13ft) length gives MCA4J80-N004 more freedom for adjacent-rack and row-end deployments. Longer copper runs need particular attention to routing weight and bend control; the ACC specification and host support must still match the intended link.
Position Within the Length Range
MCA4J80-N004 occupies the middle of this family between MCA4J80-N002 at 2m (7ft) and MCA4J80-N005 at 5m (16ft). It adds 2m over the shorter option for extra routing clearance, while the next longer version adds another 1m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.
Structured Pathways and Serviceability
Treat the direct-attach assembly as part of the permanent pathway plan even when the link is expected to be temporary. Follow the intended horizontal and vertical managers, maintain the specified bend radius and leave service access around both ports. A small, supported service allowance is preferable to excess slack concealed inside a rack or placed under cable-tie pressure. For this assembly, the listed conductor specification is 26AWG; the minimum bend radius is 59.5mm; the stated power consumption is 1.3W Per End; the jacket material is PET.
Ordering Information
Include the part number, fixed length, quantity and required pathway or rack grouping in the order information. The host model and firmware release are useful for change-controlled deployments. Different lengths should remain separate order lines so delivered labels and packing records agree with the pathway plan. Keep MCA4J80-N004 associated with 4m (13ft) throughout the order and receiving record.
NVIDIA/Mellanox Compatibility and Factory Testing
Verification covers the physical connectors, expected host identity and an operating link with available diagnostic indications. We distinguish this complete check from a simple continuity test. Platform model and software release can be reviewed in advance where the installation has strict documentation or change-control requirements. Where supported by the host, link stability and diagnostic indications are reviewed together with the established link.
Shipping and Lead Time
Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. Worldwide courier services are available, with air or sea freight for consolidated shipments; freight-collect delivery and coordination with a customer’s logistics provider can be arranged.
Quality Assurance and Packaging
After connector inspection and link verification, the assembly is coiled without tight bends and packed with end protection. Labels can cross-reference the customer cable schedule, OEM part number and length. This supports both receiving checks and later moves, adds or changes. Neutral packaging and customer-specific packing documentation are available on request.
Frequently Asked Questions
Is this an original NVIDIA/Mellanox cable?
No. It is an HT-manufactured compatible alternative for equipment that specifies NVIDIA/Mellanox MCA4J80-N004.
Are separate transceivers or patch leads required?
No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.
Can excess cable be folded into a compact bundle?
No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.
Will any matching connector operate at the same speed?
Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.
MCA4J80-N004