You are here Transceivers MCA4K50-X01A

NVIDIA/Mellanox MCA4K50-X01A Compatible 1.6T OSFP224 8 x 200G PAM4 IHS/Finned Top InfiniBand XDR Active Copper Twinax Cable, 1.5m (5ft)

NVIDIA/Mellanox MCA4K50-X01A Compatible 1.6T OSFP224 8 x 200G PAM4 IHS/Finned Top InfiniBand XDR Active Copper Twinax Cable, 1.5m (5ft)

This page covers one precise cable-schedule item: NVIDIA/Mellanox MCA4K50-X01A in 1.5m (5ft), supporting 1.6T operation through OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top). The complete ACC assembly is identified separately from other lengths and includes verified specifications, change-control-friendly ordering details and live-link factory checks.

OEM Part Number: MCA4K50-X01AHT Part Number: MCA4K50-X01A

Product Highlights

  • Compatible alternative to NVIDIA/Mellanox MCA4K50-X01A
  • 1.6T connectivity at 1600Gbps
  • Interface configuration: OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)
  • Fixed length and part number: 1.5m (5ft), MCA4K50-X01A
  • Cable construction: Active DAC (ACC)
  • Conductor specification: 30AWG
  • Maximum power consumption: 2W Per End
  • Minimum bend radius: 50mm

Specifications

HT Part NumberMCA4K50-X01A
NVIDIA/Mellanox InfiniBand CompatibleMCA4K50-X01A
ManufacturerHT
Form FactorOSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)
Max. Data Rate1600Gbps
MediaCopper
Cable TypeActive DAC (ACC)
Cable Length1.5m (5ft)
Jacket MaterialPET
Minimum Bend Radius50mm
Wire AWG30AWG
Max. Power Consumption2W Per End
Modulation Format8x 200G-PAM4 to 8x 200G-PAM4
Commercial Temperature Range0 to 70°C (32 to 158°F)
Application1.6T InfiniBand
ProtocolsOSFP Rev 5.2, IEEE 802.3df, IEEE 802.3dj, CMIS 5.0

Signal and Lane Configuration

The listed modulation format is 8x 200G-PAM4 to 8x 200G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Position Within the Length Range

MCA4K50-X01A occupies the middle of this family between MCA4K50-X001 at 1.1m (3.6ft) and MCA4K50-X002 at 2m (7ft). It adds 0.4m over the shorter option for extra routing clearance, while the next longer version adds another 0.5m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.

Structured Pathways and Serviceability

Treat the direct-attach assembly as part of the permanent pathway plan even when the link is expected to be temporary. Follow the intended horizontal and vertical managers, maintain the specified bend radius and leave service access around both ports. A small, supported service allowance is preferable to excess slack concealed inside a rack or placed under cable-tie pressure. For this assembly, the listed conductor specification is 30AWG; the minimum bend radius is 50mm; the stated power consumption is 2W Per End; the jacket material is PET.

Power and Thermal Planning

The rated power consumption is 2W Per End. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Cable Construction and Routing

This assembly uses 30AWG conductors, PET jacket, minimum bend radius 50mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is 1.6T InfiniBand. Listed interface and protocol references include OSFP Rev 5.2, IEEE 802.3df, IEEE 802.3dj, CMIS 5.0. Confirm that the host firmware and port configuration support the same operating mode.

Length Selection and Installation Planning

The additional half metre beyond a one-metre assembly gives MCA4K50-X01A useful routing flexibility when the ports are not directly aligned. It can accommodate a different rack unit or a short service loop, but excess cable should be dressed loosely rather than folded into a tight coil.

Ordering Information

Include the part number, fixed length, quantity and required pathway or rack grouping in the order information. The host model and firmware release are useful for change-controlled deployments. Different lengths should remain separate order lines so delivered labels and packing records agree with the pathway plan. This page’s fixed configuration is 1.5m (5ft); another length must be quoted under its corresponding part number.

NVIDIA/Mellanox Compatibility and Factory Testing

Verification covers the physical connectors, expected host identity and an operating link with available diagnostic indications. We distinguish this complete check from a simple continuity test. Platform model and software release can be reviewed in advance where the installation has strict documentation or change-control requirements. The check includes link stability and diagnostic indications, followed by a final inspection of both ends.

Shipping and Lead Time

Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. International express, air cargo and sea freight can be selected according to destination and carton volume; customer courier accounts and nominated forwarders are also accepted.

Quality Assurance and Packaging

After connector inspection and link verification, the assembly is coiled without tight bends and packed with end protection. Labels can cross-reference the customer cable schedule, OEM part number and length. This supports both receiving checks and later moves, adds or changes. Standard protective packing is used by default, with project documentation arranged when requested.

Frequently Asked Questions

Is this an original NVIDIA/Mellanox cable?

No. It is an HT-manufactured compatible alternative for equipment that specifies NVIDIA/Mellanox MCA4K50-X01A.

Are separate transceivers or patch leads required?

No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.

Can excess cable be folded into a compact bundle?

No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.

Will any matching connector operate at the same speed?

Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.

New Zealand Fiber Optics

New Zealand Fiber Optics

New Zealand Service center: New Zealand 0632, Auckland.

Factory in Asia: Shangxue Industrial Area, Shenzhen

Product Datasheets

For PDF documents of products data sheet or any general inquiry, email info@huihongfiber.com and we will send you the details.

Customer Support

For customer support, please email sales@huihongfiber.com; our Auckland service team will respond promptly.