You are here Transceivers MCA7K10-X001

NVIDIA/Mellanox MCA7K10-X001 Compatible 1.6T OSFP224 8 x 200G PAM4 IHS/Finned Top to 2x 800G OSFP224 4x 200G PAM4 RHS/Flat Top InfiniBand XDR Active Copper Breakout Cable, 1m (3ft)

NVIDIA/Mellanox MCA7K10-X001 Compatible 1.6T OSFP224 8 x 200G PAM4 IHS/Finned Top to 2x 800G OSFP224 4x 200G PAM4 RHS/Flat Top InfiniBand XDR Active Copper Breakout Cable, 1m (3ft)

For structured equipment cabling that specifies NVIDIA/Mellanox MCA7K10-X001, this 1m (3ft) assembly provides a complete 1.6T ACC link. Its configuration is OSFP224 (IHS/Finned Top) to 2x OSFP224 (RHS/Flat Top). The page brings together mechanical specifications, pathway considerations and compatibility verification so the product can be incorporated into a serviceable installation plan.

OEM Part Number: MCA7K10-X001HT Part Number: MCA7K10-X001

Product Highlights

  • Compatible alternative to NVIDIA/Mellanox MCA7K10-X001
  • 1.6T connectivity at 1600Gbps
  • Interface configuration: OSFP224 (IHS/Finned Top) to 2x OSFP224 (RHS/Flat Top)
  • Fixed length and part number: 1m (3ft), MCA7K10-X001
  • Cable construction: Active Breakout DAC (ACC)
  • Conductor specification: 26AWG
  • Maximum power consumption: 2W (1.6T End)2W (800G Per End)
  • Minimum bend radius: 45mm

Specifications

HT Part NumberMCA7K10-X001
NVIDIA/Mellanox InfiniBand CompatibleMCA7K10-X001
ManufacturerHT
Form FactorOSFP224 (IHS/Finned Top) to 2x OSFP224 (RHS/Flat Top)
Max. Data Rate1600Gbps
MediaCopper
Cable TypeActive Breakout DAC (ACC)
Cable Length1m (3ft)
Jacket MaterialPET/VW-1
Minimum Bend Radius45mm
Wire AWG26AWG
Max. Power Consumption2W (1.6T End)2W (800G Per End)
Modulation Format8x 200G-PAM4 to Dual 4x 200G-PAM4
Commercial Temperature Range0 to 70°C (32 to 158°F)
Application1.6T/800G InfiniBand
ProtocolsOSFP Rev 5.2, IEEE 802.3df, IEEE 802.3dj, CMIS 5.0

Signal and Lane Configuration

The listed modulation format is 8x 200G-PAM4 to Dual 4x 200G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Cable Construction and Routing

This assembly uses 26AWG conductors, PET/VW-1 jacket, minimum bend radius 45mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is 1.6T/800G InfiniBand. Listed interface and protocol references include OSFP Rev 5.2, IEEE 802.3df, IEEE 802.3dj, CMIS 5.0. Confirm that the host firmware and port configuration support the same operating mode.

Breakout Port Mapping

The OSFP224 (IHS/Finned Top) to 2x OSFP224 (RHS/Flat Top) configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.

Length Selection and Installation Planning

At 1m (3ft), MCA7K10-X001 is a practical choice for direct connections within one rack. Route the cable along the intended management path rather than pulling it diagonally across adjacent connectors, and leave enough clearance for insertion, removal and front-panel airflow.

Position Within the Length Range

MCA7K10-X001 is the shortest of 3 verified length options in this family. It is the preferred choice when the port positions are close and cable slack must be kept to a minimum. The next option is MCA7K10-X01A at 1.5m (5ft), adding 0.5m for a less direct routing path; selecting it unnecessarily would leave more cable to dress.

Structured Pathways and Serviceability

Treat the direct-attach assembly as part of the permanent pathway plan even when the link is expected to be temporary. Follow the intended horizontal and vertical managers, maintain the specified bend radius and leave service access around both ports. A small, supported service allowance is preferable to excess slack concealed inside a rack or placed under cable-tie pressure. For this assembly, the listed conductor specification is 26AWG; the minimum bend radius is 45mm; the stated power consumption is 2W (1.6T End)2W (800G Per End); the jacket material is PET/VW-1.

Power and Thermal Planning

The rated power consumption is 2W (1.6T End)2W (800G Per End). Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Ordering Information

Include the part number, fixed length, quantity and required pathway or rack grouping in the order information. The host model and firmware release are useful for change-controlled deployments. Different lengths should remain separate order lines so delivered labels and packing records agree with the pathway plan. Quantity and any labeling instructions should be attached specifically to MCA7K10-X001.

NVIDIA/Mellanox Compatibility and Factory Testing

Verification covers the physical connectors, expected host identity and an operating link with available diagnostic indications. We distinguish this complete check from a simple continuity test. Platform model and software release can be reviewed in advance where the installation has strict documentation or change-control requirements. Both connectors are examined before the operating test, which includes link stability and diagnostic indications.

Shipping and Lead Time

Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. International express, air cargo and sea freight can be selected according to destination and carton volume; customer courier accounts and nominated forwarders are also accepted.

Quality Assurance and Packaging

After connector inspection and link verification, the assembly is coiled without tight bends and packed with end protection. Labels can cross-reference the customer cable schedule, OEM part number and length. This supports both receiving checks and later moves, adds or changes. Volume orders can include customer references on the labels and carton list.

Frequently Asked Questions

Is this an original NVIDIA/Mellanox cable?

No. It is an HT-manufactured compatible alternative for equipment that specifies NVIDIA/Mellanox MCA7K10-X001.

Will any matching connector operate at the same speed?

Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.

What details assist a compatibility review?

Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.

How should an unused assembly be stored?

Protect both connector ends, keep the cable in a loose bend-safe coil and retain its part-number label so the length and compatibility identity remain traceable.

New Zealand Fiber Optics

New Zealand Fiber Optics

New Zealand Service center: New Zealand 0632, Auckland.

Factory in Asia: Shangxue Industrial Area, Shenzhen

Product Datasheets

For PDF documents of products data sheet or any general inquiry, email info@huihongfiber.com and we will send you the details.

Customer Support

For customer support, please email sales@huihongfiber.com; our Auckland service team will respond promptly.