You are here Transceivers MCP7H50-H00AR30

NVIDIA/Mellanox MCP7H50-H00AR30 Compatible 200G QSFP56 4 x 50G PAM4 to 2 x 100G QSFP56 2 x 50G PAM4 InfiniBand HDR Passive Copper Breakout Cable, 0.5m (2ft)

NVIDIA/Mellanox MCP7H50-H00AR30 Compatible 200G QSFP56 4 x 50G PAM4 to 2 x 100G QSFP56 2 x 50G PAM4 InfiniBand HDR Passive Copper Breakout Cable, 0.5m (2ft)

The MCP7H50-H00AR30 compatible cable combines 200G DAC connectivity with a defined 0.5m (2ft) pathway between QSFP56 to 2 QSFP56 interfaces. It is intended for NVIDIA/Mellanox equipment and is documented here as a distinct order code, allowing cable schedules, service access and related length selections to be reviewed before installation.

OEM Part Number: MCP7H50-H00AR30HT Part Number: MCP7H50-H00AR30

Product Highlights

  • Compatible alternative to NVIDIA/Mellanox MCP7H50-H00AR30
  • 200G connectivity at 200Gbps
  • Interface configuration: QSFP56 to 2 QSFP56
  • Fixed length and part number: 0.5m (2ft), MCP7H50-H00AR30
  • Cable construction: Passive Twinax
  • Conductor specification: 30AWG
  • Maximum power consumption: 0.1W (200G End) 0.1W (100G Per End)
  • Minimum bend radius: 26mm

Specifications

HT Part NumberMCP7H50-H00AR30
NVIDIA/Mellanox InfiniBand CompatibleMCP7H50-H00AR30
ManufacturerHT
Form FactorQSFP56 to 2 QSFP56
Max. Data Rate200Gbps
Cable Length0.5m (2ft)
Cable TypePassive Twinax
Minimum Bend Radius26mm
Wire AWG30AWG
Jacket MaterialPVC (OFNR)
Max. Power Consumption0.1W (200G End) 0.1W (100G Per End)
ProtocolsIEEE 802.3cd, SFF-8665, SFF-8665
Commercial Temperature Range0 to 70°C (32 to 158°F)

Power and Thermal Planning

The rated power consumption is 0.1W (200G End) 0.1W (100G Per End). Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Length Selection and Installation Planning

The 0.5m (2ft) length is suited to closely aligned ports where excessive slack would obstruct airflow or complicate dressing. Measure the actual port-to-port path before choosing MCP7H50-H00AR30; even a short assembly must retain the specified bend radius and should never be pulled tight behind the equipment.

Position Within the Length Range

MCP7H50-H00AR30 is the shortest of 4 verified length options in this family. It is the preferred choice when the port positions are close and cable slack must be kept to a minimum. The next option is MCP7H50-H001R30 at 1m (3ft), adding 0.5m for a less direct routing path; selecting it unnecessarily would leave more cable to dress.

Structured Pathways and Serviceability

Treat the direct-attach assembly as part of the permanent pathway plan even when the link is expected to be temporary. Follow the intended horizontal and vertical managers, maintain the specified bend radius and leave service access around both ports. A small, supported service allowance is preferable to excess slack concealed inside a rack or placed under cable-tie pressure. For this assembly, the listed conductor specification is 30AWG; the minimum bend radius is 26mm; the stated power consumption is 0.1W (200G End) 0.1W (100G Per End); the jacket material is PVC (OFNR).

Cable Construction and Routing

This assembly uses 30AWG conductors, PVC (OFNR) jacket, minimum bend radius 26mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is determined by the host interface and protocol support. Listed interface and protocol references include IEEE 802.3cd, SFF-8665, SFF-8665. Confirm that the host firmware and port configuration support the same operating mode.

Breakout Port Mapping

The QSFP56 to 2 QSFP56 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.

Passive Copper Operation

A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.

Ordering Information

Include the part number, fixed length, quantity and required pathway or rack grouping in the order information. The host model and firmware release are useful for change-controlled deployments. Different lengths should remain separate order lines so delivered labels and packing records agree with the pathway plan. Keep MCP7H50-H00AR30 associated with 0.5m (2ft) throughout the order and receiving record.

NVIDIA/Mellanox Compatibility and Factory Testing

Verification covers the physical connectors, expected host identity and an operating link with available diagnostic indications. We distinguish this complete check from a simple continuity test. Platform model and software release can be reviewed in advance where the installation has strict documentation or change-control requirements. Both connectors are examined before the operating test, which includes link stability and diagnostic indications.

Shipping and Lead Time

Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. Delivery can be arranged by courier, air freight or sea freight, and goods may instead be handed to an appointed forwarder or shipped on the customer’s courier account.

Quality Assurance and Packaging

After connector inspection and link verification, the assembly is coiled without tight bends and packed with end protection. Labels can cross-reference the customer cable schedule, OEM part number and length. This supports both receiving checks and later moves, adds or changes. Neutral packaging and customer-specific packing documentation are available on request.

Frequently Asked Questions

Is this an original NVIDIA/Mellanox cable?

No. It is an HT-manufactured compatible alternative for equipment that specifies NVIDIA/Mellanox MCP7H50-H00AR30.

Does this order code cover multiple lengths?

No. MCP7H50-H00AR30 refers here to 0.5m (2ft). Every other verified length has a separate part number and page in the length list.

Are separate transceivers or patch leads required?

No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.

Can excess cable be folded into a compact bundle?

No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.

New Zealand Fiber Optics

New Zealand Fiber Optics

New Zealand Service center: New Zealand 0632, Auckland.

Factory in Asia: Shangxue Industrial Area, Shenzhen

Product Datasheets

For PDF documents of products data sheet or any general inquiry, email info@huihongfiber.com and we will send you the details.

Customer Support

For customer support, please email sales@huihongfiber.com; our Auckland service team will respond promptly.