OSFP (IHS/Finned Top) to 4x QSFP112-800G-DAC-1.5M5FT 800G Twin-port OSFP 8 x 100G PAM4 IHS/Finned Top to 4 x 200G QSFP112 2 x 100G PAM4 Passive Copper Breakout Cable, 1.5m (5ft)

This page covers one precise cable-schedule item: Generic OSFP (IHS/Finned Top) to 4x QSFP112-800G-DAC-1.5M5FT in 1.5m (5ft), supporting 800G operation through OSFP (IHS/Finned Top) to 4x QSFP112. The complete DAC assembly is identified separately from other lengths and includes verified specifications, change-control-friendly ordering details and live-link factory checks.
OEM Part Number: OSFP (IHS/Finned Top) to 4x QSFP112-800G-DAC-1.5M5FTHT Part Number: OSFP (IHS/Finned Top) to 4x QSFP112-800G-DAC-1.5M5FT
Product Highlights
- HT-manufactured DAC assembly in 1.5m (5ft)
- 800G connectivity at 800Gbps
- Interface configuration: OSFP (IHS/Finned Top) to 4x QSFP112
- Fixed length and part number: 1.5m (5ft), OSFP (IHS/Finned Top) to 4x QSFP112-800G-DAC-1.5M5FT
- Cable construction: Passive Breakout DAC
- Conductor specification: 28AWG
- Maximum power consumption: 0.1W (OSFP End)0.1W (QSFP112 Per End)
- Minimum bend radius: 31mm
Specifications
| HT Part Number | OSFP (IHS/Finned Top) to 4x QSFP112-800G-DAC-1.5M5FT |
|---|---|
| Manufacturer | HT |
| Form Factor | OSFP (IHS/Finned Top) to 4x QSFP112 |
| Max. Data Rate | 800Gbps |
| Media | Copper |
| Cable Type | Passive Breakout DAC |
| Cable Length | 1.5m (5ft) |
| Jacket Material | PVC |
| Minimum Bend Radius | 31mm |
| Wire AWG | 28AWG |
| Max. Power Consumption | 0.1W (OSFP End)0.1W (QSFP112 Per End) |
| Modulation Format | OSFP-8x 100G-PAM4QSFP112-2x 100G-PAM4 |
| Commercial Temperature Range | 0 to 70°C (32 to 158°F) |
| Application | 800G/200G Ethernet |
| Protocols | OSFP MSA, QSFP112 MSA, IEEE 802.3ck, CMIS v5.0 |
Signal and Lane Configuration
The listed modulation format is OSFP-8x 100G-PAM4QSFP112-2x 100G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.
Passive Copper Operation
A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.
Length Selection and Installation Planning
The additional half metre beyond a one-metre assembly gives OSFP (IHS/Finned Top) to 4x QSFP112-800G-DAC-1.5M5FT useful routing flexibility when the ports are not directly aligned. It can accommodate a different rack unit or a short service loop, but excess cable should be dressed loosely rather than folded into a tight coil.
Position Within the Length Range
OSFP (IHS/Finned Top) to 4x QSFP112-800G-DAC-1.5M5FT occupies the middle of this family between OSFP (IHS/Finned Top) to 4x QSFP112-800G-DAC-1M3FT at 1m (3ft) and OSFP (IHS/Finned Top) to 4x QSFP112-800G-DAC-2M7FT at 2m (7ft). It adds 0.5m over the shorter option for extra routing clearance, while the next longer version adds another 0.5m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.
Structured Pathways and Serviceability
Treat the direct-attach assembly as part of the permanent pathway plan even when the link is expected to be temporary. Follow the intended horizontal and vertical managers, maintain the specified bend radius and leave service access around both ports. A small, supported service allowance is preferable to excess slack concealed inside a rack or placed under cable-tie pressure. For this assembly, the listed conductor specification is 28AWG; the minimum bend radius is 31mm; the stated power consumption is 0.1W (OSFP End)0.1W (QSFP112 Per End); the jacket material is PVC.
Power and Thermal Planning
The rated power consumption is 0.1W (OSFP End)0.1W (QSFP112 Per End). Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
Cable Construction and Routing
This assembly uses 28AWG conductors, PVC jacket, minimum bend radius 31mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
Network and Protocol Considerations
The intended application is 800G/200G Ethernet. Listed interface and protocol references include OSFP MSA, QSFP112 MSA, IEEE 802.3ck, CMIS v5.0. Confirm that the host firmware and port configuration support the same operating mode.
Breakout Port Mapping
The OSFP (IHS/Finned Top) to 4x QSFP112 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.
Ordering Information
Include the part number, fixed length, quantity and required pathway or rack grouping in the order information. The host model and firmware release are useful for change-controlled deployments. Different lengths should remain separate order lines so delivered labels and packing records agree with the pathway plan. This page’s fixed configuration is 1.5m (5ft); another length must be quoted under its corresponding part number.
Generic Compatibility and Factory Testing
Verification covers the physical connectors, expected host identity and an operating link with available diagnostic indications. We distinguish this complete check from a simple continuity test. Platform model and software release can be reviewed in advance where the installation has strict documentation or change-control requirements. Both connectors are examined before the operating test, which includes link stability and diagnostic indications.
Shipping and Lead Time
Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. Delivery can be arranged by courier, air freight or sea freight, and goods may instead be handed to an appointed forwarder or shipped on the customer’s courier account.
Quality Assurance and Packaging
After connector inspection and link verification, the assembly is coiled without tight bends and packed with end protection. Labels can cross-reference the customer cable schedule, OEM part number and length. This supports both receiving checks and later moves, adds or changes. Standard protective packing is used by default, with project documentation arranged when requested.
Frequently Asked Questions
Is this an original equipment manufacturer cable?
No. It is manufactured by HT under our own manufacturer identity.
Will any matching connector operate at the same speed?
Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.
What details assist a compatibility review?
Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.
How should an unused assembly be stored?
Protect both connector ends, keep the cable in a loose bend-safe coil and retain its part-number label so the length and compatibility identity remain traceable.
Generic 800G DAC