OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-800G-AEC-3M10FT 800G OSFP 8 x 100G PAM4 IHS/Finned Top Active Electrical Cable, 3m (10ft)

The OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-800G-AEC-3M10FT compatible cable combines 800G AEC connectivity with a defined 3m (10ft) pathway between OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top) interfaces. It is intended for Generic equipment and is documented here as a distinct order code, allowing cable schedules, service access and related length selections to be reviewed before installation.
OEM Part Number: OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-800G-AEC-3M10FTHT Part Number: OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-800G-AEC-3M10FT
Product Highlights
- HT-manufactured AEC assembly in 3m (10ft)
- 800G connectivity at 800Gbps
- Interface configuration: OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)
- Fixed length and part number: 3m (10ft), OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-800G-AEC-3M10FT
- Cable construction: Active DAC (AEC)
- Conductor specification: 32AWG
- Maximum power consumption: ≤12W
- Minimum bend radius: 36.5mm
Specifications
| HT Part Number | OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-800G-AEC-3M10FT |
|---|---|
| Manufacturer | HT |
| Form Factor | OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top) |
| Max Data Rate | 800Gbps |
| Media | Copper |
| Cable Type | Active DAC (AEC) |
| Minimum Bend Radius | 36.5mm |
| Power Consumption | ≤12W |
| Cable Length | 3m (10ft) |
| Wire AWG | 32AWG |
| Commercial Temperature Range | 0 to 70°C (32 to 158°F) |
| Jacket Material | PET |
| Protocols | OSFP MSA, IEEE 802.3ck, CMIS 5.0 |
| Modulation Format | 8x100G-PAM4 |
Signal and Lane Configuration
The listed modulation format is 8x100G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.
Position Within the Length Range
OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-800G-AEC-3M10FT occupies the middle of this family between OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-800G-AEC-2M7FT at 2m (7ft) and OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-800G-AEC-4M13FT at 4m (13ft). It adds 1m over the shorter option for extra routing clearance, while the next longer version adds another 1m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.
Structured Pathways and Serviceability
Treat the direct-attach assembly as part of the permanent pathway plan even when the link is expected to be temporary. Follow the intended horizontal and vertical managers, maintain the specified bend radius and leave service access around both ports. A small, supported service allowance is preferable to excess slack concealed inside a rack or placed under cable-tie pressure. For this assembly, the listed conductor specification is 32AWG; the minimum bend radius is 36.5mm; the stated power consumption is ≤12W; the jacket material is PET.
Power and Thermal Planning
The rated power consumption is ≤12W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
Cable Construction and Routing
This assembly uses 32AWG conductors, PET jacket, minimum bend radius 36.5mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
Network and Protocol Considerations
The intended application is determined by the host interface and protocol support. Listed interface and protocol references include OSFP MSA, IEEE 802.3ck, CMIS 5.0. Confirm that the host firmware and port configuration support the same operating mode.
Length Selection and Installation Planning
At 3m (10ft), this assembly can bridge non-aligned ports or adjacent racks while remaining a single direct-attach link. Support longer horizontal runs with suitable cable management and preserve space for cooling and future maintenance.
Ordering Information
Include the part number, fixed length, quantity and required pathway or rack grouping in the order information. The host model and firmware release are useful for change-controlled deployments. Different lengths should remain separate order lines so delivered labels and packing records agree with the pathway plan. Quantity and any labeling instructions should be attached specifically to OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-800G-AEC-3M10FT.
Generic Compatibility and Factory Testing
Verification covers the physical connectors, expected host identity and an operating link with available diagnostic indications. We distinguish this complete check from a simple continuity test. Platform model and software release can be reviewed in advance where the installation has strict documentation or change-control requirements. The check includes link stability and diagnostic indications, followed by a final inspection of both ends.
Shipping and Lead Time
Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. Delivery can be arranged by courier, air freight or sea freight, and goods may instead be handed to an appointed forwarder or shipped on the customer’s courier account.
Quality Assurance and Packaging
After connector inspection and link verification, the assembly is coiled without tight bends and packed with end protection. Labels can cross-reference the customer cable schedule, OEM part number and length. This supports both receiving checks and later moves, adds or changes. Volume orders can include customer references on the labels and carton list.
Frequently Asked Questions
Is this an original equipment manufacturer cable?
No. It is manufactured by HT under our own manufacturer identity.
Can different brands be connected with the same assembly?
Only where both hosts explicitly support the complete interface and compatibility arrangement. Document each end and select the appropriate brand-specific product when required.
Does this order code cover multiple lengths?
No. OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-800G-AEC-3M10FT refers here to 3m (10ft). Every other verified length has a separate part number and page in the length list.
Are separate transceivers or patch leads required?
No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.
Generic 800G AEC