You are here Transceivers Generic 800G AOC

OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-800G-AOC-25M82FT 800G OSFP 8 x 100G PAM4 IHS/Finned Top Active Optical Cable, 25m (82ft)

OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-800G-AOC-25M82FT 800G OSFP 8 x 100G PAM4 IHS/Finned Top Active Optical Cable, 25m (82ft)

For structured equipment cabling that specifies Generic OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-800G-AOC-25M82FT, this 25m (82ft) assembly provides a complete 800G AOC link. Its configuration is OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top). The page brings together mechanical specifications, pathway considerations and compatibility verification so the product can be incorporated into a serviceable installation plan.

OEM Part Number: OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-800G-AOC-25M82FTHT Part Number: OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-800G-AOC-25M82FT

Product Highlights

  • HT-manufactured AOC assembly in 25m (82ft)
  • 800G connectivity at 800Gbps
  • Interface configuration: OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)
  • Fixed length and part number: 25m (82ft), OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-800G-AOC-25M82FT
  • Cable construction: Active Optical Cable
  • Maximum power consumption: 14W Per End
  • Minimum bend radius: 30mm
  • Operating temperature: 0 to 70°C (32 to 158°F)

Specifications

HT Part NumberOSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-800G-AOC-25M82FT
ManufacturerHT
Form FactorOSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)
Max. Data Rate800Gbps
Cable Length25m (82ft)
Cable TypeActive Optical Cable
Wavelength850nm
Minimum Bend Radius30mm
Transmitter TypeVCSEL
Receiver TypePIN
Max. Power Consumption14W Per End
Modulation Format8x 100G-PAM4
CDR (Clock and Data Recovery)TX & RX Built-in CDR
Jacket MaterialOFNP
DDM/DOMSupported
Commercial Temperature Range0 to 70°C (32 to 158°F)
ProtocolsOSFP MSA, CMIS Rev 4.0, SFF-8679, IEEE 802.3bs

Signal and Lane Configuration

The listed modulation format is 8x 100G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Network and Protocol Considerations

The intended application is determined by the host interface and protocol support. Listed interface and protocol references include OSFP MSA, CMIS Rev 4.0, SFF-8679, IEEE 802.3bs. Confirm that the host firmware and port configuration support the same operating mode.

Integrated Optical Assembly

The optical engines and fiber are permanently integrated into this AOC. There are no detachable optical modules to clean or exchange. Handle the complete assembly by its connector housings and cable, and keep both ends matched to the same interface specification.

Length Selection and Installation Planning

A 25m (82ft) run can remain tidy when its pathway and service allowance are planned together. Keep the integrated optical cable and both optical engines away from tight cable-tie pressure, verify bend control at changes of direction and ensure that neither port supports the assembly’s weight. Record the exact order code after acceptance. Within this family, OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-800G-AOC-20M66FT is shorter at 20m (66ft), while OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-800G-AOC-30M98FT is the next longer choice at 30m (98ft); comparing those two boundaries helps avoid both tension and unnecessary slack.

Position Within the Length Range

OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-800G-AOC-25M82FT occupies the middle of this family between OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-800G-AOC-20M66FT at 20m (66ft) and OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-800G-AOC-30M98FT at 30m (98ft). It adds 5m over the shorter option for extra routing clearance, while the next longer version adds another 5m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.

Structured Pathways and Serviceability

Treat the direct-attach assembly as part of the permanent pathway plan even when the link is expected to be temporary. Follow the intended horizontal and vertical managers, maintain the specified bend radius and leave service access around both ports. A small, supported service allowance is preferable to excess slack concealed inside a rack or placed under cable-tie pressure. For this assembly, the minimum bend radius is 30mm; the stated power consumption is 14W Per End; the jacket material is OFNP.

Power and Thermal Planning

The rated power consumption is 14W Per End. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Cable Construction and Routing

This assembly uses OFNP jacket, minimum bend radius 30mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Ordering Information

Include the part number, fixed length, quantity and required pathway or rack grouping in the order information. The host model and firmware release are useful for change-controlled deployments. Different lengths should remain separate order lines so delivered labels and packing records agree with the pathway plan. Keep OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-800G-AOC-25M82FT associated with 25m (82ft) throughout the order and receiving record.

Generic Compatibility and Factory Testing

Verification covers the physical connectors, expected host identity and an operating link with available diagnostic indications. We distinguish this complete check from a simple continuity test. Platform model and software release can be reviewed in advance where the installation has strict documentation or change-control requirements. Both connectors are examined before the operating test, which includes receive activity and diagnostic indications.

Shipping and Lead Time

Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. Worldwide courier services are available, with air or sea freight for consolidated shipments; freight-collect delivery and coordination with a customer’s logistics provider can be arranged.

Quality Assurance and Packaging

After connector inspection and link verification, the assembly is coiled without tight bends and packed with end protection. Labels can cross-reference the customer cable schedule, OEM part number and length. This supports both receiving checks and later moves, adds or changes. Standard protective packing is used by default, with project documentation arranged when requested.

Frequently Asked Questions

Is this an original equipment manufacturer cable?

No. It is manufactured by HT under our own manufacturer identity.

What details assist a compatibility review?

Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.

How should an unused assembly be stored?

Protect both connector ends, keep the cable in a loose bend-safe coil and retain its part-number label so the length and compatibility identity remain traceable.

Can different brands be connected with the same assembly?

Only where both hosts explicitly support the complete interface and compatibility arrangement. Document each end and select the appropriate brand-specific product when required.

New Zealand Fiber Optics

New Zealand Fiber Optics

New Zealand Service center: New Zealand 0632, Auckland.

Factory in Asia: Shangxue Industrial Area, Shenzhen

Product Datasheets

For PDF documents of products data sheet or any general inquiry, email info@huihongfiber.com and we will send you the details.

Customer Support