You are here Transceivers Generic 1.6T ACC

OSFP (RHS/Flat Top) to OSFP (RHS/Flat Top)-1.6T-ACC-2M7FT 1.6T OSFP224 8 x 200G PAM4 RHS/Flat Top Active Copper Twinax Cable, 2m (7ft)

OSFP (RHS/Flat Top) to OSFP (RHS/Flat Top)-1.6T-ACC-2M7FT 1.6T OSFP224 8 x 200G PAM4 RHS/Flat Top Active Copper Twinax Cable, 2m (7ft)

The OSFP (RHS/Flat Top) to OSFP (RHS/Flat Top)-1.6T-ACC-2M7FT compatible cable combines 1.6T ACC connectivity with a defined 2m (7ft) pathway between OSFP (RHS/Flat Top) to OSFP (RHS/Flat Top) interfaces. It is intended for Generic equipment and is documented here as a distinct order code, allowing cable schedules, service access and related length selections to be reviewed before installation.

OEM Part Number: OSFP (RHS/Flat Top) to OSFP (RHS/Flat Top)-1.6T-ACC-2M7FTHT Part Number: OSFP (RHS/Flat Top) to OSFP (RHS/Flat Top)-1.6T-ACC-2M7FT

Product Highlights

  • HT-manufactured ACC assembly in 2m (7ft)
  • 1.6T connectivity at 1600Gbps
  • Interface configuration: OSFP (RHS/Flat Top) to OSFP (RHS/Flat Top)
  • Fixed length and part number: 2m (7ft), OSFP (RHS/Flat Top) to OSFP (RHS/Flat Top)-1.6T-ACC-2M7FT
  • Cable construction: Active DAC (ACC)
  • Conductor specification: 25AWG
  • Maximum power consumption: 2.5W Per End
  • Minimum bend radius: 60mm

Specifications

HT Part NumberOSFP (RHS/Flat Top) to OSFP (RHS/Flat Top)-1.6T-ACC-2M7FT
ManufacturerHT
Form FactorOSFP (RHS/Flat Top) to OSFP (RHS/Flat Top)
Max. Data Rate1600Gbps
MediaCopper
Cable TypeActive DAC (ACC)
Cable Length2m (7ft)
Jacket MaterialLSZH
Minimum Bend Radius60mm
Wire AWG25AWG
Max. Power Consumption2.5W Per End
Modulation Format8x 200G-PAM4 to 8x 200G-PAM4
Commercial Temperature Range0 to 70°C (32 to 158°F)
Application1.6T Ethernet
ProtocolsOSFP Rev 5.2, CMIS 5.0, IEEE 802.3df and 802.3dj

Signal and Lane Configuration

The listed modulation format is 8x 200G-PAM4 to 8x 200G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Network and Protocol Considerations

The intended application is 1.6T Ethernet. Listed interface and protocol references include OSFP Rev 5.2, CMIS 5.0, IEEE 802.3df and 802.3dj. Confirm that the host firmware and port configuration support the same operating mode.

Length Selection and Installation Planning

OSFP (RHS/Flat Top) to OSFP (RHS/Flat Top)-1.6T-ACC-2M7FT provides 2m (7ft) for connections between separated rack units or nearby equipment positions. Plan the route around cable managers and power cords, keeping the assembly free from connector strain while avoiding a large obstruction in the airflow path.

Position Within the Length Range

OSFP (RHS/Flat Top) to OSFP (RHS/Flat Top)-1.6T-ACC-2M7FT is the longest of 2 verified length options in this family. Compared with OSFP (RHS/Flat Top) to OSFP (RHS/Flat Top)-1.6T-ACC-1M3FT at 1m (3ft), it provides 1m of additional reach for a longer vertical drop, a wider rack or an adjacent-cabinet route. Confirm that the complete path requires this length, because unused slack still needs supported, bend-safe storage.

Structured Pathways and Serviceability

Treat the direct-attach assembly as part of the permanent pathway plan even when the link is expected to be temporary. Follow the intended horizontal and vertical managers, maintain the specified bend radius and leave service access around both ports. A small, supported service allowance is preferable to excess slack concealed inside a rack or placed under cable-tie pressure. For this assembly, the listed conductor specification is 25AWG; the minimum bend radius is 60mm; the stated power consumption is 2.5W Per End; the jacket material is LSZH.

Power and Thermal Planning

The rated power consumption is 2.5W Per End. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Cable Construction and Routing

This assembly uses 25AWG conductors, LSZH jacket, minimum bend radius 60mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Ordering Information

Include the part number, fixed length, quantity and required pathway or rack grouping in the order information. The host model and firmware release are useful for change-controlled deployments. Different lengths should remain separate order lines so delivered labels and packing records agree with the pathway plan. Quantity and any labeling instructions should be attached specifically to OSFP (RHS/Flat Top) to OSFP (RHS/Flat Top)-1.6T-ACC-2M7FT.

Generic Compatibility and Factory Testing

Verification covers the physical connectors, expected host identity and an operating link with available diagnostic indications. We distinguish this complete check from a simple continuity test. Platform model and software release can be reviewed in advance where the installation has strict documentation or change-control requirements. The check includes link stability and diagnostic indications, followed by a final inspection of both ends.

Shipping and Lead Time

Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. Worldwide courier services are available, with air or sea freight for consolidated shipments; freight-collect delivery and coordination with a customer’s logistics provider can be arranged.

Quality Assurance and Packaging

After connector inspection and link verification, the assembly is coiled without tight bends and packed with end protection. Labels can cross-reference the customer cable schedule, OEM part number and length. This supports both receiving checks and later moves, adds or changes. Standard protective packing is used by default, with project documentation arranged when requested.

Frequently Asked Questions

Is this an original equipment manufacturer cable?

No. It is manufactured by HT under our own manufacturer identity.

Will any matching connector operate at the same speed?

Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.

What details assist a compatibility review?

Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.

How should an unused assembly be stored?

Protect both connector ends, keep the cable in a loose bend-safe coil and retain its part-number label so the length and compatibility identity remain traceable.

New Zealand Fiber Optics

New Zealand Fiber Optics

New Zealand Service center: New Zealand 0632, Auckland.

Factory in Asia: Shangxue Industrial Area, Shenzhen

Product Datasheets

For PDF documents of products data sheet or any general inquiry, email info@huihongfiber.com and we will send you the details.

Customer Support

For customer support, please email sales@huihongfiber.com; our Auckland service team will respond promptly.