OSFPFL-200G-QAO-20M66FT 200G OSFP 4 x 50G PAM4 RHS/Flat Top to 200G QSFP56 4 x 50G PAM4 Active Optical Cable, 20m (66ft)

For structured equipment cabling that specifies Generic OSFPFL-200G-QAO-20M66FT, this 20m (66ft) assembly provides a complete 200G AOC link. Its configuration is OSFP (RHS/Flat Top) to QSFP56. The page brings together mechanical specifications, pathway considerations and compatibility verification so the product can be incorporated into a serviceable installation plan.
OEM Part Number: OSFPFL-200G-QAO-20M66FTHT Part Number: OSFPFL-200G-QAO-20M66FT
Product Highlights
- HT-manufactured AOC assembly in 20m (66ft)
- 200G connectivity at 200Gbps
- Interface configuration: OSFP (RHS/Flat Top) to QSFP56
- Fixed length and part number: 20m (66ft), OSFPFL-200G-QAO-20M66FT
- Cable construction: AOC
- Maximum power consumption: 10W (OSFP-FL End)5.5W (QSFP56 End)
- Minimum bend radius: 30mm
- Operating temperature: 0 to 70°C (32 to 158°F)
Specifications
| HT Part Number | OSFPFL-200G-QAO-20M66FT |
|---|---|
| Manufacturer | HT |
| Form Factor | OSFP (RHS/Flat Top) to QSFP56 |
| Max. Data Rate | 200Gbps |
| Cable Length | 1m (3ft) |
| Cable Type | AOC |
| Wavelength | 850nm |
| Minimum Bend Radius | 30mm |
| Transmitter Type | VSCEL |
| Receiver Type | PIN |
| Max. Power Consumption | 10W (OSFP-FL End)5.5W (QSFP56 End) |
| Jacket Material | OFNP |
| CDR (Clock and Data Recovery) | TX & RX Built-in CDR |
| Modulation Format | OSFP-4x 50G-PAM4QSFP56-4x 50G-PAM4 |
| DDM/DOM | Supported |
| Commercial Temperature Range | 0 to 70°C (32 to 158°F) |
| Protocols | IEEE802.3cd, IEEE 802.3bs, OSFP MSA, SFF-8636 |
Signal and Lane Configuration
The listed modulation format is OSFP-4x 50G-PAM4QSFP56-4x 50G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.
Power and Thermal Planning
The rated power consumption is 10W (OSFP-FL End)5.5W (QSFP56 End). Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
Cable Construction and Routing
This assembly uses OFNP jacket, minimum bend radius 30mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
Network and Protocol Considerations
The intended application is determined by the host interface and protocol support. Listed interface and protocol references include IEEE802.3cd, IEEE 802.3bs, OSFP MSA, SFF-8636. Confirm that the host firmware and port configuration support the same operating mode.
Integrated Optical Assembly
The optical engines and fiber are permanently integrated into this AOC. There are no detachable optical modules to clean or exchange. Handle the complete assembly by its connector housings and cable, and keep both ends matched to the same interface specification.
Length Selection and Installation Planning
With 20m (66ft) available, the installer has more routing freedom but also more cable to control. Determine where any remaining service loop will be stored, preserve the stated bend radius and keep the loop away from sharp edges and hot exhaust. The integrated optical cable and both optical engines should remain accessible for inspection and removal. Within this family, OSFPFL-200G-QAO-15M49FT is shorter at 15m (49ft), while OSFPFL-200G-QAO-25M82FT is the next longer choice at 25m (82ft); comparing those two boundaries helps avoid both tension and unnecessary slack.
Position Within the Length Range
OSFPFL-200G-QAO-20M66FT occupies the middle of this family between OSFPFL-200G-QAO-15M49FT at 15m (49ft) and OSFPFL-200G-QAO-25M82FT at 25m (82ft). It adds 5m over the shorter option for extra routing clearance, while the next longer version adds another 5m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.
Structured Pathways and Serviceability
Treat the direct-attach assembly as part of the permanent pathway plan even when the link is expected to be temporary. Follow the intended horizontal and vertical managers, maintain the specified bend radius and leave service access around both ports. A small, supported service allowance is preferable to excess slack concealed inside a rack or placed under cable-tie pressure. For this assembly, the minimum bend radius is 30mm; the stated power consumption is 10W (OSFP-FL End)5.5W (QSFP56 End); the jacket material is OFNP.
Ordering Information
Include the part number, fixed length, quantity and required pathway or rack grouping in the order information. The host model and firmware release are useful for change-controlled deployments. Different lengths should remain separate order lines so delivered labels and packing records agree with the pathway plan. Quantity and any labeling instructions should be attached specifically to OSFPFL-200G-QAO-20M66FT.
Generic Compatibility and Factory Testing
Verification covers the physical connectors, expected host identity and an operating link with available diagnostic indications. We distinguish this complete check from a simple continuity test. Platform model and software release can be reviewed in advance where the installation has strict documentation or change-control requirements. Where supported by the host, receive activity and diagnostic indications are reviewed together with the established link.
Shipping and Lead Time
Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. Delivery can be arranged by courier, air freight or sea freight, and goods may instead be handed to an appointed forwarder or shipped on the customer’s courier account.
Quality Assurance and Packaging
After connector inspection and link verification, the assembly is coiled without tight bends and packed with end protection. Labels can cross-reference the customer cable schedule, OEM part number and length. This supports both receiving checks and later moves, adds or changes. Volume orders can include customer references on the labels and carton list.
Frequently Asked Questions
Is this an original equipment manufacturer cable?
No. It is manufactured by HT under our own manufacturer identity.
Are separate transceivers or patch leads required?
No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.
Can excess cable be folded into a compact bundle?
No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.
Will any matching connector operate at the same speed?
Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.
OSFPFL-200G-QAO-20M66FT