You are here Transceivers QDD-2X100G-0.5M

Juniper Networks QDD-2X100G-0.5M Compatible 200G QSFP-DD 8 x 25G NRZ to 2 x 100G QSFP28 4 x 25G NRZ Passive Copper Breakout Cable, 0.5m (2ft)

Juniper Networks QDD-2X100G-0.5M Compatible 200G QSFP-DD 8 x 25G NRZ to 2 x 100G QSFP28 4 x 25G NRZ Passive Copper Breakout Cable, 0.5m (2ft)

For structured equipment cabling that specifies Juniper Networks QDD-2X100G-0.5M, this 0.5m (2ft) assembly provides a complete 200G DAC link. Its configuration is QSFP-DD to 2x QSFP28. The page brings together mechanical specifications, pathway considerations and compatibility verification so the product can be incorporated into a serviceable installation plan.

OEM Part Number: QDD-2X100G-0.5MHT Part Number: QDD-2X100G-0.5M

Product Highlights

  • Compatible alternative to Juniper Networks QDD-2X100G-0.5M
  • 200G connectivity at 200Gbps
  • Interface configuration: QSFP-DD to 2x QSFP28
  • Fixed length and part number: 0.5m (2ft), QDD-2X100G-0.5M
  • Cable construction: Passive Breakout DAC
  • Conductor specification: 30AWG
  • Maximum power consumption: 0.1W (QSFP-DD End)0.1W (QSFP28 Per End)
  • Minimum bend radius: 35mm

Specifications

HT Part NumberQDD-2X100G-0.5M
Juniper Networks CompatibleQDD-2X100G-0.5M
ManufacturerHT
Form FactorQSFP-DD to 2x QSFP28
Max. Data Rate200Gbps
MediaCopper
Cable TypePassive Breakout DAC
Minimum Bend Radius35mm
Wire AWG30AWG
Cable Length0.5m (2ft)
Jacket MaterialPVC
Max. Power Consumption0.1W (QSFP-DD End)0.1W (QSFP28 Per End)
Modulation FormatQSFP-DD-8x 25G-NRZQSFP28-4x 25G-NRZ
DDM/DOMNot Supported
Commercial TemperatureRange0 to 70°C (32 to 158°F)
ProtocolsQSFP-DD MSA, SFF-8661, IEEE 802.3bs-200GAUI-8, IEEE802.3bm-CAUI-4, CMIS 4.0, SFF-8636

Juniper Deployment Reference

Juniper platform documentation distinguishes straight QSFP28 DAC or AOC connections from DACBO and AOCBO breakout operation. On channelized systems, the host port must be configured for the required breakout mode. Match this HT compatible cable to the exact Juniper part number and the intended platform configuration.

Signal and Lane Configuration

The listed modulation format is QSFP-DD-8x 25G-NRZQSFP28-4x 25G-NRZ. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Power and Thermal Planning

The rated power consumption is 0.1W (QSFP-DD End)0.1W (QSFP28 Per End). Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Cable Construction and Routing

This assembly uses 30AWG conductors, PVC jacket, minimum bend radius 35mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is determined by the host interface and protocol support. Listed interface and protocol references include QSFP-DD MSA, SFF-8661, IEEE 802.3bs-200GAUI-8, IEEE802.3bm-CAUI-4, CMIS 4.0, SFF-8636. Confirm that the host firmware and port configuration support the same operating mode.

Breakout Port Mapping

The QSFP-DD to 2x QSFP28 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.

Passive Copper Operation

A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.

Length Selection and Installation Planning

The 0.5m (2ft) length is suited to closely aligned ports where excessive slack would obstruct airflow or complicate dressing. Measure the actual port-to-port path before choosing QDD-2X100G-0.5M; even a short assembly must retain the specified bend radius and should never be pulled tight behind the equipment.

Position Within the Length Range

QDD-2X100G-0.5M is the shortest of 4 verified length options in this family. It is the preferred choice when the port positions are close and cable slack must be kept to a minimum. The next option is QDD-2X100G-1M at 1m (3ft), adding 0.5m for a less direct routing path; selecting it unnecessarily would leave more cable to dress.

Structured Pathways and Serviceability

Treat the direct-attach assembly as part of the permanent pathway plan even when the link is expected to be temporary. Follow the intended horizontal and vertical managers, maintain the specified bend radius and leave service access around both ports. A small, supported service allowance is preferable to excess slack concealed inside a rack or placed under cable-tie pressure. For this assembly, the listed conductor specification is 30AWG; the minimum bend radius is 35mm; the stated power consumption is 0.1W (QSFP-DD End)0.1W (QSFP28 Per End); the jacket material is PVC.

Ordering Information

Include the part number, fixed length, quantity and required pathway or rack grouping in the order information. The host model and firmware release are useful for change-controlled deployments. Different lengths should remain separate order lines so delivered labels and packing records agree with the pathway plan. This page’s fixed configuration is 0.5m (2ft); another length must be quoted under its corresponding part number.

Juniper Networks Compatibility and Factory Testing

Verification covers the physical connectors, expected host identity and an operating link with available diagnostic indications. We distinguish this complete check from a simple continuity test. Platform model and software release can be reviewed in advance where the installation has strict documentation or change-control requirements. The check includes link stability and diagnostic indications, followed by a final inspection of both ends.

Shipping and Lead Time

Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. Delivery can be arranged by courier, air freight or sea freight, and goods may instead be handed to an appointed forwarder or shipped on the customer’s courier account.

Quality Assurance and Packaging

After connector inspection and link verification, the assembly is coiled without tight bends and packed with end protection. Labels can cross-reference the customer cable schedule, OEM part number and length. This supports both receiving checks and later moves, adds or changes. Neutral packaging and customer-specific packing documentation are available on request.

Frequently Asked Questions

Is this an original Juniper Networks cable?

No. It is an HT-manufactured compatible alternative for equipment that specifies Juniper Networks QDD-2X100G-0.5M.

Are separate transceivers or patch leads required?

No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.

Can excess cable be folded into a compact bundle?

No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.

Will any matching connector operate at the same speed?

Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.

New Zealand Fiber Optics

New Zealand Fiber Optics

New Zealand Service center: New Zealand 0632, Auckland.

Factory in Asia: Shangxue Industrial Area, Shenzhen

Product Datasheets

For PDF documents of products data sheet or any general inquiry, email info@huihongfiber.com and we will send you the details.

Customer Support

For customer support, please email sales@huihongfiber.com; our Auckland service team will respond promptly.