You are here Transceivers QSFP-4SFP25G-CU1-5M

Cisco QSFP-4SFP25G-CU1-5M Compatible 100G QSFP28 4 x 25G NRZ to 4 x 25G SFP28 NRZ Passive Copper Breakout Cable, 1.5m (5ft)

Cisco QSFP-4SFP25G-CU1-5M Compatible 100G QSFP28 4 x 25G NRZ to 4 x 25G SFP28 NRZ Passive Copper Breakout Cable, 1.5m (5ft)

This page covers one precise cable-schedule item: Cisco QSFP-4SFP25G-CU1-5M in 1.5m (5ft), supporting 100G operation through QSFP28 to SFP28. The complete DAC assembly is identified separately from other lengths and includes verified specifications, change-control-friendly ordering details and live-link factory checks.

OEM Part Number: QSFP-4SFP25G-CU1-5MHT Part Number: QSFP-4SFP25G-CU1-5M

Product Highlights

  • Compatible alternative to Cisco QSFP-4SFP25G-CU1-5M
  • 100G connectivity at 100Gbps
  • Interface configuration: QSFP28 to SFP28
  • Fixed length and part number: 1.5m (5ft), QSFP-4SFP25G-CU1-5M
  • Cable construction: Passive Twinax
  • Conductor specification: 30AWG
  • Maximum power consumption: ≤0.125W
  • Minimum bend radius: 60mm

Specifications

HT Part NumberQSFP-4SFP25G-CU1-5M
Cisco CompatibleQSFP-4SFP25G-CU1-5M
ManufacturerHT
Form FactorQSFP28 to SFP28
Max Data Rate100Gbps
Cable TypePassive Twinax
Cable Length1.5m (5ft)
Wire AWG30AWG
Minimum Bend Radius60mm
Power Consumption≤0.125W
Power Supply3.3V
MTBF=50 Million Hours
Jacket MaterialPVC (OFNR)
Commercial Temperature Range0 to 70°C (32 to 158°F)
Modulation FormatQSFP28-4x 25G-NRZ SFP28-1x 25G-NRZ
MediaCopper
Application100G to 4x 25G Ethernet, Data Centers
ProtocolsIEEE 802.3, QSFP28 MSA, SFF-8665

Cisco OEM Reference

Cisco defines QSFP-4SFP25G-CUxM as a 100G QSFP to four 25G SFP passive copper breakout assembly. One end connects to a 100G QSFP port and the four branches connect to 25G interfaces on a switch or server. Correct channelization and lane mapping are essential for this HT compatible version as well.

Passive Copper Operation

A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.

Length Selection and Installation Planning

The additional half metre beyond a one-metre assembly gives QSFP-4SFP25G-CU1-5M useful routing flexibility when the ports are not directly aligned. It can accommodate a different rack unit or a short service loop, but excess cable should be dressed loosely rather than folded into a tight coil.

Position Within the Length Range

QSFP-4SFP25G-CU1-5M occupies the middle of this family between QSFP-4SFP25G-CU1M at 1m (3ft) and QSFP-4SFP25G-CU2M at 2m (7ft). It adds 0.5m over the shorter option for extra routing clearance, while the next longer version adds another 0.5m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.

Structured Pathways and Serviceability

Treat the direct-attach assembly as part of the permanent pathway plan even when the link is expected to be temporary. Follow the intended horizontal and vertical managers, maintain the specified bend radius and leave service access around both ports. A small, supported service allowance is preferable to excess slack concealed inside a rack or placed under cable-tie pressure. For this assembly, the listed conductor specification is 30AWG; the minimum bend radius is 60mm; the stated power consumption is ≤0.125W; the jacket material is PVC (OFNR).

Signal and Lane Configuration

The listed modulation format is QSFP28-4x 25G-NRZ SFP28-1x 25G-NRZ. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Power and Thermal Planning

The rated power consumption is ≤0.125W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Cable Construction and Routing

This assembly uses 30AWG conductors, PVC (OFNR) jacket, minimum bend radius 60mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is 100G to 4x 25G Ethernet, Data Centers. Listed interface and protocol references include IEEE 802.3, QSFP28 MSA, SFF-8665. Confirm that the host firmware and port configuration support the same operating mode.

Breakout Port Mapping

The QSFP28 to SFP28 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.

Ordering Information

Include the part number, fixed length, quantity and required pathway or rack grouping in the order information. The host model and firmware release are useful for change-controlled deployments. Different lengths should remain separate order lines so delivered labels and packing records agree with the pathway plan. Keep QSFP-4SFP25G-CU1-5M associated with 1.5m (5ft) throughout the order and receiving record.

Cisco Compatibility and Factory Testing

Verification covers the physical connectors, expected host identity and an operating link with available diagnostic indications. We distinguish this complete check from a simple continuity test. Platform model and software release can be reviewed in advance where the installation has strict documentation or change-control requirements. The check includes link stability and diagnostic indications, followed by a final inspection of both ends.

Shipping and Lead Time

Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. Worldwide courier services are available, with air or sea freight for consolidated shipments; freight-collect delivery and coordination with a customer’s logistics provider can be arranged.

Quality Assurance and Packaging

After connector inspection and link verification, the assembly is coiled without tight bends and packed with end protection. Labels can cross-reference the customer cable schedule, OEM part number and length. This supports both receiving checks and later moves, adds or changes. Standard protective packing is used by default, with project documentation arranged when requested.

Frequently Asked Questions

Is this an original Cisco cable?

No. It is an HT-manufactured compatible alternative for equipment that specifies Cisco QSFP-4SFP25G-CU1-5M.

Can different brands be connected with the same assembly?

Only where both hosts explicitly support the complete interface and compatibility arrangement. Document each end and select the appropriate brand-specific product when required.

Does this order code cover multiple lengths?

No. QSFP-4SFP25G-CU1-5M refers here to 1.5m (5ft). Every other verified length has a separate part number and page in the length list.

Are separate transceivers or patch leads required?

No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.

New Zealand Fiber Optics

New Zealand Fiber Optics

New Zealand Service center: New Zealand 0632, Auckland.

Factory in Asia: Shangxue Industrial Area, Shenzhen

Product Datasheets

For PDF documents of products data sheet or any general inquiry, email info@huihongfiber.com and we will send you the details.

Customer Support

For customer support, please email sales@huihongfiber.com; our Auckland service team will respond promptly.