QSFP-DD to 2x 100G QSFP28-200G-AOC-10M33FT 200G QSFP-DD 8 x 25G NRZ to 2 x 100G QSFP28 4 x 25G NRZ Active Optical Breakout Cable, 10m (33ft)

The QSFP-DD to 2x 100G QSFP28-200G-AOC-10M33FT compatible cable combines 200G AOC connectivity with a defined 10m (33ft) pathway between QSFP-DD to 2x 100G QSFP28 interfaces. It is intended for Generic equipment and is documented here as a distinct order code, allowing cable schedules, service access and related length selections to be reviewed before installation.
OEM Part Number: QSFP-DD to 2x 100G QSFP28-200G-AOC-10M33FTHT Part Number: QSFP-DD to 2x 100G QSFP28-200G-AOC-10M33FT
Product Highlights
- HT-manufactured AOC assembly in 10m (33ft)
- 200G connectivity at 200Gbps
- Interface configuration: QSFP-DD to 2x 100G QSFP28
- Fixed length and part number: 10m (33ft), QSFP-DD to 2x 100G QSFP28-200G-AOC-10M33FT
- Cable construction: OM3
- Maximum power consumption: 4W (QSFP-DD End) 2.5W (QSFP28 Per End)
- Minimum bend radius: 30mm
- Operating temperature: 0 to 70°C (32 to 158°F)
Specifications
| HT Part Number | QSFP-DD to 2x 100G QSFP28-200G-AOC-10M33FT |
|---|---|
| Manufacturer | HT |
| Form Factor | QSFP-DD to 2x 100G QSFP28 |
| Max. Data Rate | 200Gbps |
| Cable Length | 10m (33ft) |
| Cable Type | OM3 |
| Wavelength | 850nm |
| Minimum Bend Radius | 30mm |
| Transmitter Type | VSCEL |
| Receiver Type | PIN |
| Max. Power Consumption | 4W (QSFP-DD End) 2.5W (QSFP28 Per End) |
| Jacket Material | OFNP |
| CDR (Clock and Data Recovery) | Not Supported |
| Modulation Format | NRZ |
| Commercial Temperature Range | 0 to 70°C (32 to 158°F) |
| Protocols | QSFP-DD MSA V5.0, QSFP28 MSA, CMIS V4.0, SFF-8636 |
Signal and Lane Configuration
The listed modulation format is NRZ. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.
Breakout Port Mapping
The QSFP-DD to 2x 100G QSFP28 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.
Integrated Optical Assembly
The optical engines and fiber are permanently integrated into this AOC. There are no detachable optical modules to clean or exchange. Handle the complete assembly by its connector housings and cable, and keep both ends matched to the same interface specification.
Length Selection and Installation Planning
Measure twice before deploying this 10m (33ft) cable: once along the planned route and again after accounting for service access. The objective is adequate reach without a concealed surplus. Support the integrated optical cable and both optical engines, preserve front-panel clearance and check that nearby power cords or sharp hardware cannot damage the jacket. Within this family, QSFP-DD to 2x 100G QSFP28-200G-AOC-7M23FT is shorter at 7m (23ft), while QSFP-DD to 2x 100G QSFP28-200G-AOC-15M49FT is the next longer choice at 15m (49ft); comparing those two boundaries helps avoid both tension and unnecessary slack.
Position Within the Length Range
QSFP-DD to 2x 100G QSFP28-200G-AOC-10M33FT occupies the middle of this family between QSFP-DD to 2x 100G QSFP28-200G-AOC-7M23FT at 7m (23ft) and QSFP-DD to 2x 100G QSFP28-200G-AOC-15M49FT at 15m (49ft). It adds 3m over the shorter option for extra routing clearance, while the next longer version adds another 5m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.
Structured Pathways and Serviceability
Treat the direct-attach assembly as part of the permanent pathway plan even when the link is expected to be temporary. Follow the intended horizontal and vertical managers, maintain the specified bend radius and leave service access around both ports. A small, supported service allowance is preferable to excess slack concealed inside a rack or placed under cable-tie pressure. For this assembly, the minimum bend radius is 30mm; the stated power consumption is 4W (QSFP-DD End) 2.5W (QSFP28 Per End); the jacket material is OFNP.
Power and Thermal Planning
The rated power consumption is 4W (QSFP-DD End) 2.5W (QSFP28 Per End). Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
Cable Construction and Routing
This assembly uses OFNP jacket, minimum bend radius 30mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
Network and Protocol Considerations
The intended application is determined by the host interface and protocol support. Listed interface and protocol references include QSFP-DD MSA V5.0, QSFP28 MSA, CMIS V4.0, SFF-8636. Confirm that the host firmware and port configuration support the same operating mode.
Ordering Information
Include the part number, fixed length, quantity and required pathway or rack grouping in the order information. The host model and firmware release are useful for change-controlled deployments. Different lengths should remain separate order lines so delivered labels and packing records agree with the pathway plan. This page’s fixed configuration is 10m (33ft); another length must be quoted under its corresponding part number.
Generic Compatibility and Factory Testing
Verification covers the physical connectors, expected host identity and an operating link with available diagnostic indications. We distinguish this complete check from a simple continuity test. Platform model and software release can be reviewed in advance where the installation has strict documentation or change-control requirements. Both connectors are examined before the operating test, which includes receive activity and diagnostic indications.
Shipping and Lead Time
Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. Worldwide courier services are available, with air or sea freight for consolidated shipments; freight-collect delivery and coordination with a customer’s logistics provider can be arranged.
Quality Assurance and Packaging
After connector inspection and link verification, the assembly is coiled without tight bends and packed with end protection. Labels can cross-reference the customer cable schedule, OEM part number and length. This supports both receiving checks and later moves, adds or changes. Volume orders can include customer references on the labels and carton list.
Frequently Asked Questions
Is this an original equipment manufacturer cable?
No. It is manufactured by HT under our own manufacturer identity.
Will any matching connector operate at the same speed?
Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.
What details assist a compatibility review?
Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.
How should an unused assembly be stored?
Protect both connector ends, keep the cable in a loose bend-safe coil and retain its part-number label so the length and compatibility identity remain traceable.
Generic 200G AOC