QSFP-DD to 2x QSFP28-200G-DAC-2M7FT 200G QSFP-DD 8 x 25G NRZ to 2 x 100G QSFP28 4 x 25G NRZ Passive Copper Breakout Cable, 2m (7ft)

For structured equipment cabling that specifies Generic QSFP-DD to 2x QSFP28-200G-DAC-2M7FT, this 2m (7ft) assembly provides a complete 200G DAC link. Its configuration is QSFP-DD to 2x QSFP28. The page brings together mechanical specifications, pathway considerations and compatibility verification so the product can be incorporated into a serviceable installation plan.
OEM Part Number: QSFP-DD to 2x QSFP28-200G-DAC-2M7FTHT Part Number: QSFP-DD to 2x QSFP28-200G-DAC-2M7FT
Product Highlights
- HT-manufactured DAC assembly in 2m (7ft)
- 200G connectivity at 200Gbps
- Interface configuration: QSFP-DD to 2x QSFP28
- Fixed length and part number: 2m (7ft), QSFP-DD to 2x QSFP28-200G-DAC-2M7FT
- Cable construction: Passive Breakout DAC
- Conductor specification: 28AWG
- Maximum power consumption: 0.1W (QSFP-DD End)0.1W (QSFP28 Per End)
- Minimum bend radius: 35mm
Specifications
| HT Part Number | QSFP-DD to 2x QSFP28-200G-DAC-2M7FT |
|---|---|
| Manufacturer | HT |
| Form Factor | QSFP-DD to 2x QSFP28 |
| Max. Data Rate | 200Gbps |
| Media | Copper |
| Cable Type | Passive Breakout DAC |
| Minimum Bend Radius | 35mm |
| Wire AWG | 28AWG |
| Cable Length | 2m (7ft) |
| Jacket Material | PVC |
| Max. Power Consumption | 0.1W (QSFP-DD End)0.1W (QSFP28 Per End) |
| Modulation Format | QSFP-DD-8x 25G-NRZQSFP28-4x 25G-NRZ |
| DDM/DOM | Not Supported |
| Commercial TemperatureRange | 0 to 70°C (32 to 158°F) |
| Protocols | QSFP-DD MSA, SFF-8661, IEEE 802.3bs-200GAUI-8, IEEE802.3bm-CAUI-4, CMIS 4.0, SFF-8636 |
Signal and Lane Configuration
The listed modulation format is QSFP-DD-8x 25G-NRZQSFP28-4x 25G-NRZ. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.
Power and Thermal Planning
The rated power consumption is 0.1W (QSFP-DD End)0.1W (QSFP28 Per End). Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
Cable Construction and Routing
This assembly uses 28AWG conductors, PVC jacket, minimum bend radius 35mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
Network and Protocol Considerations
The intended application is determined by the host interface and protocol support. Listed interface and protocol references include QSFP-DD MSA, SFF-8661, IEEE 802.3bs-200GAUI-8, IEEE802.3bm-CAUI-4, CMIS 4.0, SFF-8636. Confirm that the host firmware and port configuration support the same operating mode.
Breakout Port Mapping
The QSFP-DD to 2x QSFP28 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.
Passive Copper Operation
A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.
Length Selection and Installation Planning
QSFP-DD to 2x QSFP28-200G-DAC-2M7FT provides 2m (7ft) for connections between separated rack units or nearby equipment positions. Plan the route around cable managers and power cords, keeping the assembly free from connector strain while avoiding a large obstruction in the airflow path.
Position Within the Length Range
QSFP-DD to 2x QSFP28-200G-DAC-2M7FT occupies the middle of this family between QSFP-DD to 2x QSFP28-200G-DAC-1M3FT at 1m (3ft) and QSFP-DD to 2x QSFP28-200G-DAC-3M10FT at 3m (10ft). It adds 1m over the shorter option for extra routing clearance, while the next longer version adds another 1m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.
Structured Pathways and Serviceability
Treat the direct-attach assembly as part of the permanent pathway plan even when the link is expected to be temporary. Follow the intended horizontal and vertical managers, maintain the specified bend radius and leave service access around both ports. A small, supported service allowance is preferable to excess slack concealed inside a rack or placed under cable-tie pressure. For this assembly, the listed conductor specification is 28AWG; the minimum bend radius is 35mm; the stated power consumption is 0.1W (QSFP-DD End)0.1W (QSFP28 Per End); the jacket material is PVC.
Ordering Information
Include the part number, fixed length, quantity and required pathway or rack grouping in the order information. The host model and firmware release are useful for change-controlled deployments. Different lengths should remain separate order lines so delivered labels and packing records agree with the pathway plan. Quantity and any labeling instructions should be attached specifically to QSFP-DD to 2x QSFP28-200G-DAC-2M7FT.
Generic Compatibility and Factory Testing
Verification covers the physical connectors, expected host identity and an operating link with available diagnostic indications. We distinguish this complete check from a simple continuity test. Platform model and software release can be reviewed in advance where the installation has strict documentation or change-control requirements. The check includes link stability and diagnostic indications, followed by a final inspection of both ends.
Shipping and Lead Time
Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. International express, air cargo and sea freight can be selected according to destination and carton volume; customer courier accounts and nominated forwarders are also accepted.
Quality Assurance and Packaging
After connector inspection and link verification, the assembly is coiled without tight bends and packed with end protection. Labels can cross-reference the customer cable schedule, OEM part number and length. This supports both receiving checks and later moves, adds or changes. Volume orders can include customer references on the labels and carton list.
Frequently Asked Questions
Is this an original equipment manufacturer cable?
No. It is manufactured by HT under our own manufacturer identity.
What details assist a compatibility review?
Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.
How should an unused assembly be stored?
Protect both connector ends, keep the cable in a loose bend-safe coil and retain its part-number label so the length and compatibility identity remain traceable.
Can different brands be connected with the same assembly?
Only where both hosts explicitly support the complete interface and compatibility arrangement. Document each end and select the appropriate brand-specific product when required.
QSFP-DD to 2x QSFP28-200G-DAC-2M7FT