QSFP-DD to 8x 25G SFP28-200G-AOC-25M82FT 200G QSFP-DD 8 x 25G NRZ to 8 x 25G SFP28 25G NRZ Active Optical Breakout Cable, 25m (82ft)

The QSFP-DD to 8x 25G SFP28-200G-AOC-25M82FT compatible cable combines 200G AOC connectivity with a defined 25m (82ft) pathway between QSFP-DD to 8x 25G SFP28 interfaces. It is intended for Generic equipment and is documented here as a distinct order code, allowing cable schedules, service access and related length selections to be reviewed before installation.
OEM Part Number: QSFP-DD to 8x 25G SFP28-200G-AOC-25M82FTHT Part Number: QSFP-DD to 8x 25G SFP28-200G-AOC-25M82FT
Product Highlights
- HT-manufactured AOC assembly in 25m (82ft)
- 200G connectivity at 206.24Gbps (8x 25.78Gbps)
- Interface configuration: QSFP-DD to 8x 25G SFP28
- Fixed length and part number: 25m (82ft), QSFP-DD to 8x 25G SFP28-200G-AOC-25M82FT
- Cable construction: OM3
- Maximum power consumption: QSFP-DD <4W,SFP28 <1W
- Minimum bend radius: 30mm
- Operating temperature: 0 to 70°C (32 to 158°F)
Specifications
| HT Part Number | QSFP-DD to 8x 25G SFP28-200G-AOC-25M82FT |
|---|---|
| Manufacturer | HT |
| Form Factor | QSFP-DD to 8x 25G SFP28 |
| Max. Data Rate | 206.24Gbps (8x 25.78Gbps) |
| Cable Length | 25m |
| Cable Type | OM3 |
| Minimum Bend Radius | 30mm |
| Power Consumption | QSFP-DD <4W,SFP28 <1W |
| Transmitter Type | VSCEL |
| Receiver Type | PIN |
| Modulation Format | NRZ |
| BER | 5E-5 |
| Inbuilt FEC | No |
| Commercial Temperature Range | 0 to 70°C (32 to 158°F) |
| Protocols | QSFP-DD MSA V5.0,SFP28 MSA,CMIS V4.0,SFF-8472 |
Signal and Lane Configuration
The listed modulation format is NRZ. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.
Position Within the Length Range
QSFP-DD to 8x 25G SFP28-200G-AOC-25M82FT occupies the middle of this family between QSFP-DD to 8x 25G SFP28-200G-AOC-20M66FT at 20m (66ft) and QSFP-DD to 8x 25G SFP28-200G-AOC-30M98FT at 30m (98ft). It adds 5m over the shorter option for extra routing clearance, while the next longer version adds another 5m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.
Structured Pathways and Serviceability
Treat the direct-attach assembly as part of the permanent pathway plan even when the link is expected to be temporary. Follow the intended horizontal and vertical managers, maintain the specified bend radius and leave service access around both ports. A small, supported service allowance is preferable to excess slack concealed inside a rack or placed under cable-tie pressure. For this assembly, the minimum bend radius is 30mm; the stated power consumption is QSFP-DD <4W,SFP28 <1W.
Power and Thermal Planning
The rated power consumption is QSFP-DD <4W,SFP28 <1W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
Cable Construction and Routing
This assembly uses minimum bend radius 30mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
Network and Protocol Considerations
The intended application is determined by the host interface and protocol support. Listed interface and protocol references include QSFP-DD MSA V5.0,SFP28 MSA,CMIS V4.0,SFF-8472. Confirm that the host firmware and port configuration support the same operating mode.
Breakout Port Mapping
The QSFP-DD to 8x 25G SFP28 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.
Integrated Optical Assembly
The optical engines and fiber are permanently integrated into this AOC. There are no detachable optical modules to clean or exchange. Handle the complete assembly by its connector housings and cable, and keep both ends matched to the same interface specification.
Length Selection and Installation Planning
The 25m (82ft) reach of QSFP-DD to 8x 25G SFP28-200G-AOC-25M82FT is useful only when the managed pathway requires it; straight-line distance between ports is not a sufficient measurement. Check the route around rack rails, cable managers and maintenance clearances, then protect the integrated optical cable and both optical engines from tight bends and unsupported spans. Within this family, QSFP-DD to 8x 25G SFP28-200G-AOC-20M66FT is shorter at 20m (66ft), while QSFP-DD to 8x 25G SFP28-200G-AOC-30M98FT is the next longer choice at 30m (98ft); comparing those two boundaries helps avoid both tension and unnecessary slack.
Ordering Information
Include the part number, fixed length, quantity and required pathway or rack grouping in the order information. The host model and firmware release are useful for change-controlled deployments. Different lengths should remain separate order lines so delivered labels and packing records agree with the pathway plan. Keep QSFP-DD to 8x 25G SFP28-200G-AOC-25M82FT associated with 25m (82ft) throughout the order and receiving record.
Generic Compatibility and Factory Testing
Verification covers the physical connectors, expected host identity and an operating link with available diagnostic indications. We distinguish this complete check from a simple continuity test. Platform model and software release can be reviewed in advance where the installation has strict documentation or change-control requirements. Both connectors are examined before the operating test, which includes receive activity and diagnostic indications.
Shipping and Lead Time
Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. International express, air cargo and sea freight can be selected according to destination and carton volume; customer courier accounts and nominated forwarders are also accepted.
Quality Assurance and Packaging
After connector inspection and link verification, the assembly is coiled without tight bends and packed with end protection. Labels can cross-reference the customer cable schedule, OEM part number and length. This supports both receiving checks and later moves, adds or changes. Volume orders can include customer references on the labels and carton list.
Frequently Asked Questions
Is this an original equipment manufacturer cable?
No. It is manufactured by HT under our own manufacturer identity.
Can different brands be connected with the same assembly?
Only where both hosts explicitly support the complete interface and compatibility arrangement. Document each end and select the appropriate brand-specific product when required.
Does this order code cover multiple lengths?
No. QSFP-DD to 8x 25G SFP28-200G-AOC-25M82FT refers here to 25m (82ft). Every other verified length has a separate part number and page in the length list.
Are separate transceivers or patch leads required?
No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.