You are here Transceivers Generic 400G AOC

QSFP-DD to 8x 50G SFP56-400G-AOC-7M23FT 400G QSFP-DD 8 x 50G PAM4 to 8 x 50G SFP56 25G NRZ Active Optical Breakout Cable, 7m (23ft)

QSFP-DD to 8x 50G SFP56-400G-AOC-7M23FT 400G QSFP-DD 8 x 50G PAM4 to 8 x 50G SFP56 25G NRZ Active Optical Breakout Cable, 7m (23ft)

For structured equipment cabling that specifies Generic QSFP-DD to 8x 50G SFP56-400G-AOC-7M23FT, this 7m (23ft) assembly provides a complete 400G AOC link. Its configuration is QSFP-DD to 8x 50G SFP56. The page brings together mechanical specifications, pathway considerations and compatibility verification so the product can be incorporated into a serviceable installation plan.

OEM Part Number: QSFP-DD to 8x 50G SFP56-400G-AOC-7M23FTHT Part Number: QSFP-DD to 8x 50G SFP56-400G-AOC-7M23FT

Product Highlights

  • HT-manufactured AOC assembly in 7m (23ft)
  • 400G connectivity at 425Gbps (8x 53.125GGbps)
  • Interface configuration: QSFP-DD to 8x 50G SFP56
  • Fixed length and part number: 7m (23ft), QSFP-DD to 8x 50G SFP56-400G-AOC-7M23FT
  • Cable construction: OM3
  • Maximum power consumption: 10W (QSFP-DD End) 3W (SFP56 Per End)
  • Minimum bend radius: 30mm

Specifications

HT Part NumberQSFP-DD to 8x 50G SFP56-400G-AOC-7M23FT
ManufacturerHT
Form FactorQSFP-DD to 8x 50G SFP56
Max. Data Rate425Gbps (8x 53.125GGbps)
Cable Length7m
Cable TypeOM3
Minimum Bend Radius30mm
Max. Power Consumption10W (QSFP-DD End) 3W (SFP56 Per End)
Transmitter TypeVSCEL
Receiver TypePIN
Modulation FormatPAM4
Wavelength850nm
Jacket MaterialOFNP
BER2.4E-4
Inbuilt FECNo
Operating Temperature Range0 to 70°C (32 to 158°F)
ProtocolsQSFP-DD MSA, SFP56 MSA, IEEE 802.3cd

Signal and Lane Configuration

The listed modulation format is PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Breakout Port Mapping

The QSFP-DD to 8x 50G SFP56 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.

Integrated Optical Assembly

The optical engines and fiber are permanently integrated into this AOC. There are no detachable optical modules to clean or exchange. Handle the complete assembly by its connector housings and cable, and keep both ends matched to the same interface specification.

Length Selection and Installation Planning

At 7m (23ft), QSFP-DD to 8x 50G SFP56-400G-AOC-7M23FT should be planned as an extended equipment-room connection rather than a short in-rack jumper. Mark the complete vertical and horizontal route before installation, including every manager the cable will actually pass through. Support the integrated optical cable and both optical engines along that path and keep both ends free from pull loads. Within this family, QSFP-DD to 8x 50G SFP56-400G-AOC-5M16FT is shorter at 5m (16ft), while QSFP-DD to 8x 50G SFP56-400G-AOC-10M33FT is the next longer choice at 10m (33ft); comparing those two boundaries helps avoid both tension and unnecessary slack.

Position Within the Length Range

QSFP-DD to 8x 50G SFP56-400G-AOC-7M23FT occupies the middle of this family between QSFP-DD to 8x 50G SFP56-400G-AOC-5M16FT at 5m (16ft) and QSFP-DD to 8x 50G SFP56-400G-AOC-10M33FT at 10m (33ft). It adds 2m over the shorter option for extra routing clearance, while the next longer version adds another 3m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.

Structured Pathways and Serviceability

Treat the direct-attach assembly as part of the permanent pathway plan even when the link is expected to be temporary. Follow the intended horizontal and vertical managers, maintain the specified bend radius and leave service access around both ports. A small, supported service allowance is preferable to excess slack concealed inside a rack or placed under cable-tie pressure. For this assembly, the minimum bend radius is 30mm; the stated power consumption is 10W (QSFP-DD End) 3W (SFP56 Per End); the jacket material is OFNP.

Power and Thermal Planning

The rated power consumption is 10W (QSFP-DD End) 3W (SFP56 Per End). Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Cable Construction and Routing

This assembly uses OFNP jacket, minimum bend radius 30mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is determined by the host interface and protocol support. Listed interface and protocol references include QSFP-DD MSA, SFP56 MSA, IEEE 802.3cd. Confirm that the host firmware and port configuration support the same operating mode.

Ordering Information

Include the part number, fixed length, quantity and required pathway or rack grouping in the order information. The host model and firmware release are useful for change-controlled deployments. Different lengths should remain separate order lines so delivered labels and packing records agree with the pathway plan. Keep QSFP-DD to 8x 50G SFP56-400G-AOC-7M23FT associated with 7m (23ft) throughout the order and receiving record.

Generic Compatibility and Factory Testing

Verification covers the physical connectors, expected host identity and an operating link with available diagnostic indications. We distinguish this complete check from a simple continuity test. Platform model and software release can be reviewed in advance where the installation has strict documentation or change-control requirements. Where supported by the host, receive activity and diagnostic indications are reviewed together with the established link.

Shipping and Lead Time

Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. International express, air cargo and sea freight can be selected according to destination and carton volume; customer courier accounts and nominated forwarders are also accepted.

Quality Assurance and Packaging

After connector inspection and link verification, the assembly is coiled without tight bends and packed with end protection. Labels can cross-reference the customer cable schedule, OEM part number and length. This supports both receiving checks and later moves, adds or changes. Volume orders can include customer references on the labels and carton list.

Frequently Asked Questions

Is this an original equipment manufacturer cable?

No. It is manufactured by HT under our own manufacturer identity.

Will any matching connector operate at the same speed?

Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.

What details assist a compatibility review?

Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.

How should an unused assembly be stored?

Protect both connector ends, keep the cable in a loose bend-safe coil and retain its part-number label so the length and compatibility identity remain traceable.

New Zealand Fiber Optics

New Zealand Fiber Optics

New Zealand Service center: New Zealand 0632, Auckland.

Factory in Asia: Shangxue Industrial Area, Shenzhen

Product Datasheets

For PDF documents of products data sheet or any general inquiry, email info@huihongfiber.com and we will send you the details.

Customer Support

For customer support, please email sales@huihongfiber.com; our Auckland service team will respond promptly.