You are here Transceivers QSFP-DD to QSFP-DD-800G-AEC-5M16FT

QSFP-DD to QSFP-DD-800G-AEC-5M16FT 800G QSFP-DD 8 x 100G PAM4 Active Electrical Cable, 5m (16ft)

QSFP-DD to QSFP-DD-800G-AEC-5M16FT 800G QSFP-DD 8 x 100G PAM4 Active Electrical Cable, 5m (16ft)

For structured equipment cabling that specifies Generic QSFP-DD to QSFP-DD-800G-AEC-5M16FT, this 5m (16ft) assembly provides a complete 800G AEC link. Its configuration is QSFP-DD to QSFP-DD. The page brings together mechanical specifications, pathway considerations and compatibility verification so the product can be incorporated into a serviceable installation plan.

OEM Part Number: QSFP-DD to QSFP-DD-800G-AEC-5M16FTHT Part Number: QSFP-DD to QSFP-DD-800G-AEC-5M16FT

Product Highlights

  • HT-manufactured AEC assembly in 5m (16ft)
  • 800G connectivity at 800Gbps
  • Interface configuration: QSFP-DD to QSFP-DD
  • Fixed length and part number: 5m (16ft), QSFP-DD to QSFP-DD-800G-AEC-5M16FT
  • Cable construction: Active DAC (AEC)
  • Conductor specification: 32AWG
  • Maximum power consumption: 12W Per End
  • Minimum bend radius: 36.5

Specifications

HT Part NumberQSFP-DD to QSFP-DD-800G-AEC-5M16FT
ManufacturerHT
Form FactorQSFP-DD to QSFP-DD
Max. Data Rate800Gbps
MediaCopper
Cable TypeActive DAC (AEC)
Cable Length5m (16ft)
Jacket MaterialPET
Minimum Bend Radius36.5
Wire AWG32AWG
Max. Power Consumption12W Per End
Modulation Format8x100G-PAM4
Commercial Temperature Range0 to 70°C (32 to 158°F)
Application800G Ethernet
ProtocolsCMIS 5.0, IEEE 802.3ck, QSFP-DD MSA Rev6.3

Signal and Lane Configuration

The listed modulation format is 8x100G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Position Within the Length Range

QSFP-DD to QSFP-DD-800G-AEC-5M16FT is the longest of 4 verified length options in this family. Compared with QSFP-DD to QSFP-DD-800G-AEC-3M10FT at 3m (10ft), it provides 2m of additional reach for a longer vertical drop, a wider rack or an adjacent-cabinet route. Confirm that the complete path requires this length, because unused slack still needs supported, bend-safe storage.

Structured Pathways and Serviceability

Treat the direct-attach assembly as part of the permanent pathway plan even when the link is expected to be temporary. Follow the intended horizontal and vertical managers, maintain the specified bend radius and leave service access around both ports. A small, supported service allowance is preferable to excess slack concealed inside a rack or placed under cable-tie pressure. For this assembly, the listed conductor specification is 32AWG; the minimum bend radius is 36.5; the stated power consumption is 12W Per End; the jacket material is PET.

Power and Thermal Planning

The rated power consumption is 12W Per End. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Cable Construction and Routing

This assembly uses 32AWG conductors, PET jacket, minimum bend radius 36.5. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is 800G Ethernet. Listed interface and protocol references include CMIS 5.0, IEEE 802.3ck, QSFP-DD MSA Rev6.3. Confirm that the host firmware and port configuration support the same operating mode.

Length Selection and Installation Planning

The 5m (16ft) length gives QSFP-DD to QSFP-DD-800G-AEC-5M16FT more freedom for adjacent-rack and row-end deployments. Longer copper runs need particular attention to routing weight and bend control; the AEC specification and host support must still match the intended link.

Ordering Information

Include the part number, fixed length, quantity and required pathway or rack grouping in the order information. The host model and firmware release are useful for change-controlled deployments. Different lengths should remain separate order lines so delivered labels and packing records agree with the pathway plan. This page’s fixed configuration is 5m (16ft); another length must be quoted under its corresponding part number.

Generic Compatibility and Factory Testing

Verification covers the physical connectors, expected host identity and an operating link with available diagnostic indications. We distinguish this complete check from a simple continuity test. Platform model and software release can be reviewed in advance where the installation has strict documentation or change-control requirements. Where supported by the host, link stability and diagnostic indications are reviewed together with the established link.

Shipping and Lead Time

Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. Delivery can be arranged by courier, air freight or sea freight, and goods may instead be handed to an appointed forwarder or shipped on the customer’s courier account.

Quality Assurance and Packaging

After connector inspection and link verification, the assembly is coiled without tight bends and packed with end protection. Labels can cross-reference the customer cable schedule, OEM part number and length. This supports both receiving checks and later moves, adds or changes. Volume orders can include customer references on the labels and carton list.

Frequently Asked Questions

Is this an original equipment manufacturer cable?

No. It is manufactured by HT under our own manufacturer identity.

Are separate transceivers or patch leads required?

No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.

Can excess cable be folded into a compact bundle?

No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.

Will any matching connector operate at the same speed?

Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.

New Zealand Fiber Optics

New Zealand Fiber Optics

New Zealand Service center: New Zealand 0632, Auckland.

Factory in Asia: Shangxue Industrial Area, Shenzhen

Product Datasheets

For PDF documents of products data sheet or any general inquiry, email info@huihongfiber.com and we will send you the details.

Customer Support

For customer support, please email sales@huihongfiber.com; our Auckland service team will respond promptly.