QSFP28 to 2x QSFP28-100G-AOC-1M3FT 100G QSFP28 4 x 25G NRZ to 2 x 50G QSFP28 2 x 25G NRZ Active Optical Breakout Cable, 1m (3ft)

The QSFP28 to 2x QSFP28-100G-AOC-1M3FT compatible cable combines 100G AOC connectivity with a defined 1m (3ft) pathway between QSFP28 to 2x QSFP28 interfaces. It is intended for Generic equipment and is documented here as a distinct order code, allowing cable schedules, service access and related length selections to be reviewed before installation.
OEM Part Number: QSFP28 to 2x QSFP28-100G-AOC-1M3FTHT Part Number: QSFP28 to 2x QSFP28-100G-AOC-1M3FT
Product Highlights
- HT-manufactured AOC assembly in 1m (3ft)
- 100G connectivity at 100Gbps
- Interface configuration: QSFP28 to 2x QSFP28
- Fixed length and part number: 1m (3ft), QSFP28 to 2x QSFP28-100G-AOC-1M3FT
- Cable construction: Breakout AOC
- Maximum power consumption: 2.2W (100G Per End)1.5W (50G Per End)
- Minimum bend radius: 30mm
- Operating temperature: 0 to 70°C (32 to 158°F)
Specifications
| HT Part Number | QSFP28 to 2x QSFP28-100G-AOC-1M3FT |
|---|---|
| Manufacturer | HT |
| Form Factor | QSFP28 to 2x QSFP28 |
| Max. Data Rate | 100Gbps |
| Cable Length | 1m (3ft) |
| Cable Type | Breakout AOC |
| Wavelength | 850nm |
| Minimum Bend Radius | 30mm |
| Transmitter Type | VSCEL |
| Receiver Type | PIN |
| Max. Power Consumption | 2.2W (100G Per End)1.5W (50G Per End) |
| Modulation Format | 4x 25G-NRZ to 2x 25G-NRZ |
| CDR (Clock and Data Recovery) | TX & RX Built-in CDR |
| Jacket Material | OFNP |
| DDM/DOM | Supported |
| Commercial Temperature Range | 0 to 70°C (32 to 158°F) |
| Protocols | QSFP28 Electrical MSA, SFF-8636, SFF-8665 |
Signal and Lane Configuration
The listed modulation format is 4x 25G-NRZ to 2x 25G-NRZ. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.
Cable Construction and Routing
This assembly uses OFNP jacket, minimum bend radius 30mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
Network and Protocol Considerations
The intended application is determined by the host interface and protocol support. Listed interface and protocol references include QSFP28 Electrical MSA, SFF-8636, SFF-8665. Confirm that the host firmware and port configuration support the same operating mode.
Breakout Port Mapping
The QSFP28 to 2x QSFP28 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.
Integrated Optical Assembly
The optical engines and fiber are permanently integrated into this AOC. There are no detachable optical modules to clean or exchange. Handle the complete assembly by its connector housings and cable, and keep both ends matched to the same interface specification.
Length Selection and Installation Planning
At 1m (3ft), QSFP28 to 2x QSFP28-100G-AOC-1M3FT is a practical choice for direct connections within one rack. Route the cable along the intended management path rather than pulling it diagonally across adjacent connectors, and leave enough clearance for insertion, removal and front-panel airflow.
Position Within the Length Range
QSFP28 to 2x QSFP28-100G-AOC-1M3FT is the shortest of 10 verified length options in this family. It is the preferred choice when the port positions are close and cable slack must be kept to a minimum. The next option is QSFP28 to 2x QSFP28-100G-AOC-3M10FT at 3m (10ft), adding 2m for a less direct routing path; selecting it unnecessarily would leave more cable to dress.
Structured Pathways and Serviceability
Treat the direct-attach assembly as part of the permanent pathway plan even when the link is expected to be temporary. Follow the intended horizontal and vertical managers, maintain the specified bend radius and leave service access around both ports. A small, supported service allowance is preferable to excess slack concealed inside a rack or placed under cable-tie pressure. For this assembly, the minimum bend radius is 30mm; the stated power consumption is 2.2W (100G Per End)1.5W (50G Per End); the jacket material is OFNP.
Power and Thermal Planning
The rated power consumption is 2.2W (100G Per End)1.5W (50G Per End). Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
Ordering Information
Include the part number, fixed length, quantity and required pathway or rack grouping in the order information. The host model and firmware release are useful for change-controlled deployments. Different lengths should remain separate order lines so delivered labels and packing records agree with the pathway plan. Quantity and any labeling instructions should be attached specifically to QSFP28 to 2x QSFP28-100G-AOC-1M3FT.
Generic Compatibility and Factory Testing
Verification covers the physical connectors, expected host identity and an operating link with available diagnostic indications. We distinguish this complete check from a simple continuity test. Platform model and software release can be reviewed in advance where the installation has strict documentation or change-control requirements. The check includes receive activity and diagnostic indications, followed by a final inspection of both ends.
Shipping and Lead Time
Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. International express, air cargo and sea freight can be selected according to destination and carton volume; customer courier accounts and nominated forwarders are also accepted.
Quality Assurance and Packaging
After connector inspection and link verification, the assembly is coiled without tight bends and packed with end protection. Labels can cross-reference the customer cable schedule, OEM part number and length. This supports both receiving checks and later moves, adds or changes. Volume orders can include customer references on the labels and carton list.
Frequently Asked Questions
Is this an original equipment manufacturer cable?
No. It is manufactured by HT under our own manufacturer identity.
How should an unused assembly be stored?
Protect both connector ends, keep the cable in a loose bend-safe coil and retain its part-number label so the length and compatibility identity remain traceable.
Can different brands be connected with the same assembly?
Only where both hosts explicitly support the complete interface and compatibility arrangement. Document each end and select the appropriate brand-specific product when required.
Does this order code cover multiple lengths?
No. QSFP28 to 2x QSFP28-100G-AOC-1M3FT refers here to 1m (3ft). Every other verified length has a separate part number and page in the length list.
QSFP28 to 2x QSFP28-100G-AOC-1M3FT