You are here Transceivers Generic 100G AOC

QSFP28 to 4 duplex LC-100G-AOC-50M164FT 100G QSFP28 4 x 25G NRZ to 4 Duplex LC 25G NRZ Active Optical Breakout Cable, 50m (164ft)

QSFP28 to 4 duplex LC-100G-AOC-50M164FT 100G QSFP28 4 x 25G NRZ to 4 Duplex LC 25G NRZ Active Optical Breakout Cable, 50m (164ft)

This page covers one precise cable-schedule item: Generic QSFP28 to 4 duplex LC-100G-AOC-50M164FT in 50m (164ft), supporting 100G operation through QSFP28 to 4 duplex LC. The complete AOC assembly is identified separately from other lengths and includes verified specifications, change-control-friendly ordering details and live-link factory checks.

OEM Part Number: QSFP28 to 4 duplex LC-100G-AOC-50M164FTHT Part Number: QSFP28 to 4 duplex LC-100G-AOC-50M164FT

Product Highlights

  • HT-manufactured AOC assembly in 50m (164ft)
  • 100G connectivity at 100Gbps
  • Interface configuration: QSFP28 to 4 duplex LC
  • Fixed length and part number: 50m (164ft), QSFP28 to 4 duplex LC-100G-AOC-50M164FT
  • Cable construction: Breakout AOC
  • Maximum power consumption: 2.2W
  • Minimum bend radius: 20mm
  • Operating temperature: 0 to 70°C (32 to 158°F)

Specifications

HT Part NumberQSFP28 to 4 duplex LC-100G-AOC-50M164FT
ManufacturerHT
Form FactorQSFP28 to 4 duplex LC
Max. Data Rate100Gbps
Cable Length50m (164ft)
Cable TypeBreakout AOC
Wavelength850nm
Minimum Bend Radius20mm
Transmitter TypeVCSEL
Receiver TypePIN
Max. Power Consumption2.2W
Modulation FormatQSFP28-4x 25G-NRZ Duplex LC-1x 25G-NRZ
CDR (Clock and Data Recovery)TX & RX Built-in CDR
Jacket MaterialOFNP
DDM/DOMSupported
Commercial Temperature Range0 to 70°C (32 to 158°F)
ProtocolsSFF-8436, SFF-8431

Signal and Lane Configuration

The listed modulation format is QSFP28-4x 25G-NRZ Duplex LC-1x 25G-NRZ. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Length Selection and Installation Planning

Longer assemblies require disciplined cable dressing. For QSFP28 to 4 duplex LC-100G-AOC-50M164FT at 50m (164ft), use the intended managers rather than a diagonal route across the rack, and leave enough space to release each connector. Any service allowance should be loose and supported, with the integrated optical cable and both optical engines protected throughout the path. Within this family, QSFP28 to 4 duplex LC-100G-AOC-30M98FT is shorter at 30m (98ft), while QSFP28 to 4 duplex LC-100G-AOC-70M230FT is the next longer choice at 70m (230ft); comparing those two boundaries helps avoid both tension and unnecessary slack.

Position Within the Length Range

QSFP28 to 4 duplex LC-100G-AOC-50M164FT occupies the middle of this family between QSFP28 to 4 duplex LC-100G-AOC-30M98FT at 30m (98ft) and QSFP28 to 4 duplex LC-100G-AOC-70M230FT at 70m (230ft). It adds 20m over the shorter option for extra routing clearance, while the next longer version adds another 20m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.

Structured Pathways and Serviceability

Treat the direct-attach assembly as part of the permanent pathway plan even when the link is expected to be temporary. Follow the intended horizontal and vertical managers, maintain the specified bend radius and leave service access around both ports. A small, supported service allowance is preferable to excess slack concealed inside a rack or placed under cable-tie pressure. For this assembly, the minimum bend radius is 20mm; the stated power consumption is 2.2W; the jacket material is OFNP.

Power and Thermal Planning

The rated power consumption is 2.2W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Cable Construction and Routing

This assembly uses OFNP jacket, minimum bend radius 20mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is determined by the host interface and protocol support. Listed interface and protocol references include SFF-8436, SFF-8431. Confirm that the host firmware and port configuration support the same operating mode.

Breakout Port Mapping

The QSFP28 to 4 duplex LC configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.

Integrated Optical Assembly

The optical engines and fiber are permanently integrated into this AOC. There are no detachable optical modules to clean or exchange. Handle the complete assembly by its connector housings and cable, and keep both ends matched to the same interface specification.

Ordering Information

Include the part number, fixed length, quantity and required pathway or rack grouping in the order information. The host model and firmware release are useful for change-controlled deployments. Different lengths should remain separate order lines so delivered labels and packing records agree with the pathway plan. Quantity and any labeling instructions should be attached specifically to QSFP28 to 4 duplex LC-100G-AOC-50M164FT.

Generic Compatibility and Factory Testing

Verification covers the physical connectors, expected host identity and an operating link with available diagnostic indications. We distinguish this complete check from a simple continuity test. Platform model and software release can be reviewed in advance where the installation has strict documentation or change-control requirements. Where supported by the host, receive activity and diagnostic indications are reviewed together with the established link.

Shipping and Lead Time

Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. Worldwide courier services are available, with air or sea freight for consolidated shipments; freight-collect delivery and coordination with a customer’s logistics provider can be arranged.

Quality Assurance and Packaging

After connector inspection and link verification, the assembly is coiled without tight bends and packed with end protection. Labels can cross-reference the customer cable schedule, OEM part number and length. This supports both receiving checks and later moves, adds or changes. Volume orders can include customer references on the labels and carton list.

Frequently Asked Questions

Is this an original equipment manufacturer cable?

No. It is manufactured by HT under our own manufacturer identity.

Can excess cable be folded into a compact bundle?

No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.

Will any matching connector operate at the same speed?

Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.

What details assist a compatibility review?

Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.

New Zealand Fiber Optics

New Zealand Fiber Optics

New Zealand Service center: New Zealand 0632, Auckland.

Factory in Asia: Shangxue Industrial Area, Shenzhen

Product Datasheets

For PDF documents of products data sheet or any general inquiry, email info@huihongfiber.com and we will send you the details.

Customer Support

For customer support, please email sales@huihongfiber.com; our Auckland service team will respond promptly.