You are here Transceivers QSFP28 to 4x SFP28-100G-DAC-9M29FT

QSFP28 to 4x SFP28-100G-DAC-9M29FT 100G QSFP28 4 x 25G NRZ to 4 x 25G SFP28 NRZ Active Copper Breakout Cable, 9m (29ft)

QSFP28 to 4x SFP28-100G-DAC-9M29FT 100G QSFP28 4 x 25G NRZ to 4 x 25G SFP28 NRZ Active Copper Breakout Cable, 9m (29ft)

The QSFP28 to 4x SFP28-100G-DAC-9M29FT compatible cable combines 100G DAC connectivity with a defined 9m (29ft) pathway between QSFP28 to 4x SFP28 interfaces. It is intended for Generic equipment and is documented here as a distinct order code, allowing cable schedules, service access and related length selections to be reviewed before installation.

OEM Part Number: QSFP28 to 4x SFP28-100G-DAC-9M29FTHT Part Number: QSFP28 to 4x SFP28-100G-DAC-9M29FT

Product Highlights

  • HT-manufactured DAC assembly in 9m (29ft)
  • 100G connectivity at 100Gbps
  • Interface configuration: QSFP28 to 4x SFP28
  • Fixed length and part number: 9m (29ft), QSFP28 to 4x SFP28-100G-DAC-9M29FT
  • Cable construction: Active Breakout DAC
  • Conductor specification: 26AWG
  • Maximum power consumption: 1.8W
  • Minimum bend radius: 44.5mm

Specifications

HT Part NumberQSFP28 to 4x SFP28-100G-DAC-9M29FT
ManufacturerHT
Form FactorQSFP28 to 4x SFP28
Max. Data Rate100Gbps
MediaCopper
Cable TypeActive Breakout DAC
Cable Length9m (29ft)
Jacket MaterialPVC (OFNR)
Minimum Bend Radius44.5mm
Wire AWG26AWG
Max. Power Consumption1.8W
Modulation FormatQSFP28-4x 25G-NRZ SFP28-1x 25G-NRZ
Commercial Temperature Range0 to 70°C (32 to 158°F)
Application100G/25G Ethernet
ProtocolsQSFP28 MSA, SFP28 MSA, SFF-8665, SFF-8679, SFF-8472, SFF-8402

Signal and Lane Configuration

The listed modulation format is QSFP28-4x 25G-NRZ SFP28-1x 25G-NRZ. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Position Within the Length Range

QSFP28 to 4x SFP28-100G-DAC-9M29FT is the longest of 5 verified length options in this family. Compared with QSFP28 to 4x SFP28-100G-DAC-7M23FT at 7m (23ft), it provides 2m of additional reach for a longer vertical drop, a wider rack or an adjacent-cabinet route. Confirm that the complete path requires this length, because unused slack still needs supported, bend-safe storage.

Structured Pathways and Serviceability

Treat the direct-attach assembly as part of the permanent pathway plan even when the link is expected to be temporary. Follow the intended horizontal and vertical managers, maintain the specified bend radius and leave service access around both ports. A small, supported service allowance is preferable to excess slack concealed inside a rack or placed under cable-tie pressure. For this assembly, the listed conductor specification is 26AWG; the minimum bend radius is 44.5mm; the stated power consumption is 1.8W; the jacket material is PVC (OFNR).

Power and Thermal Planning

The rated power consumption is 1.8W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Cable Construction and Routing

This assembly uses 26AWG conductors, PVC (OFNR) jacket, minimum bend radius 44.5mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is 100G/25G Ethernet. Listed interface and protocol references include QSFP28 MSA, SFP28 MSA, SFF-8665, SFF-8679, SFF-8472, SFF-8402. Confirm that the host firmware and port configuration support the same operating mode.

Breakout Port Mapping

The QSFP28 to 4x SFP28 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.

Passive Copper Operation

A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.

Length Selection and Installation Planning

Measure twice before deploying this 9m (29ft) cable: once along the planned route and again after accounting for service access. The objective is adequate reach without a concealed surplus. Support the complete copper assembly and both connector housings, preserve front-panel clearance and check that nearby power cords or sharp hardware cannot damage the jacket. The next shorter verified assembly is QSFP28 to 4x SFP28-100G-DAC-7M23FT at 7m (23ft), which is the better comparison when the managed route leaves substantial unused cable.

Ordering Information

Include the part number, fixed length, quantity and required pathway or rack grouping in the order information. The host model and firmware release are useful for change-controlled deployments. Different lengths should remain separate order lines so delivered labels and packing records agree with the pathway plan. This page’s fixed configuration is 9m (29ft); another length must be quoted under its corresponding part number.

Generic Compatibility and Factory Testing

Verification covers the physical connectors, expected host identity and an operating link with available diagnostic indications. We distinguish this complete check from a simple continuity test. Platform model and software release can be reviewed in advance where the installation has strict documentation or change-control requirements. Where supported by the host, link stability and diagnostic indications are reviewed together with the established link.

Shipping and Lead Time

Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. Worldwide courier services are available, with air or sea freight for consolidated shipments; freight-collect delivery and coordination with a customer’s logistics provider can be arranged.

Quality Assurance and Packaging

After connector inspection and link verification, the assembly is coiled without tight bends and packed with end protection. Labels can cross-reference the customer cable schedule, OEM part number and length. This supports both receiving checks and later moves, adds or changes. Standard protective packing is used by default, with project documentation arranged when requested.

Frequently Asked Questions

Is this an original equipment manufacturer cable?

No. It is manufactured by HT under our own manufacturer identity.

Can excess cable be folded into a compact bundle?

No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.

Will any matching connector operate at the same speed?

Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.

What details assist a compatibility review?

Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.

New Zealand Fiber Optics

New Zealand Fiber Optics

New Zealand Service center: New Zealand 0632, Auckland.

Factory in Asia: Shangxue Industrial Area, Shenzhen

Product Datasheets

For PDF documents of products data sheet or any general inquiry, email info@huihongfiber.com and we will send you the details.

Customer Support

For customer support, please email sales@huihongfiber.com; our Auckland service team will respond promptly.