QSFP56 to QSFP56-200G-ACC-7M23FT 200G QSFP56 4 x 50G PAM4 Active Copper Twinax Cable, 7m (23ft)

This page covers one precise cable-schedule item: Generic QSFP56 to QSFP56-200G-ACC-7M23FT in 7m (23ft), supporting 200G operation through QSFP56 to QSFP56. The complete ACC assembly is identified separately from other lengths and includes verified specifications, change-control-friendly ordering details and live-link factory checks.
OEM Part Number: QSFP56 to QSFP56-200G-ACC-7M23FTHT Part Number: QSFP56 to QSFP56-200G-ACC-7M23FT
Product Highlights
- HT-manufactured ACC assembly in 7m (23ft)
- 200G connectivity at 200Gbps
- Interface configuration: QSFP56 to QSFP56
- Fixed length and part number: 7m (23ft), QSFP56 to QSFP56-200G-ACC-7M23FT
- Cable construction: Active Twinax
- Conductor specification: 26AWG
- Maximum power consumption: 1.5W Per End
- Minimum bend radius: 44.5mm
Specifications
| HT Part Number | QSFP56 to QSFP56-200G-ACC-7M23FT |
|---|---|
| Manufacturer | HT |
| Form Factor | QSFP56 to QSFP56 |
| Max. Data Rate | 200Gbps |
| Media | Copper |
| Cable Type | Active Twinax |
| Cable Length | 7m (23ft) |
| Wire AWG | 26AWG |
| Minimum Bend Radius | 44.5mm |
| Max. Power Consumption | 1.5W Per End |
| Jacket Material | PVC (OFNR) |
| Commercial Temperature Range | 0 to 70°C (32 to 158°F) |
| Protocols | IEEE 802.3cd, SFF-8665, SFF-8679, SFF-8636 |
Power and Thermal Planning
The rated power consumption is 1.5W Per End. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
Network and Protocol Considerations
The intended application is determined by the host interface and protocol support. Listed interface and protocol references include IEEE 802.3cd, SFF-8665, SFF-8679, SFF-8636. Confirm that the host firmware and port configuration support the same operating mode.
Length Selection and Installation Planning
For this 7m (23ft) version, prepare the destination pathway before connecting either end. A longer assembly can cross separated equipment positions, but its weight and service slack must remain supported without blocking airflow. Handle the complete copper assembly and both connector housings as one factory-terminated product and never pull a connector into position by the cable. The next shorter verified assembly is QSFP56 to QSFP56-200G-ACC-5M16FT at 5m (16ft), which is the better comparison when the managed route leaves substantial unused cable.
Position Within the Length Range
QSFP56 to QSFP56-200G-ACC-7M23FT is the longest of 4 verified length options in this family. Compared with QSFP56 to QSFP56-200G-ACC-5M16FT at 5m (16ft), it provides 2m of additional reach for a longer vertical drop, a wider rack or an adjacent-cabinet route. Confirm that the complete path requires this length, because unused slack still needs supported, bend-safe storage.
Structured Pathways and Serviceability
Treat the direct-attach assembly as part of the permanent pathway plan even when the link is expected to be temporary. Follow the intended horizontal and vertical managers, maintain the specified bend radius and leave service access around both ports. A small, supported service allowance is preferable to excess slack concealed inside a rack or placed under cable-tie pressure. For this assembly, the listed conductor specification is 26AWG; the minimum bend radius is 44.5mm; the stated power consumption is 1.5W Per End; the jacket material is PVC (OFNR).
Cable Construction and Routing
This assembly uses 26AWG conductors, PVC (OFNR) jacket, minimum bend radius 44.5mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
Ordering Information
Include the part number, fixed length, quantity and required pathway or rack grouping in the order information. The host model and firmware release are useful for change-controlled deployments. Different lengths should remain separate order lines so delivered labels and packing records agree with the pathway plan. Keep QSFP56 to QSFP56-200G-ACC-7M23FT associated with 7m (23ft) throughout the order and receiving record.
Generic Compatibility and Factory Testing
Verification covers the physical connectors, expected host identity and an operating link with available diagnostic indications. We distinguish this complete check from a simple continuity test. Platform model and software release can be reviewed in advance where the installation has strict documentation or change-control requirements. Where supported by the host, link stability and diagnostic indications are reviewed together with the established link.
Shipping and Lead Time
Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. International express, air cargo and sea freight can be selected according to destination and carton volume; customer courier accounts and nominated forwarders are also accepted.
Quality Assurance and Packaging
After connector inspection and link verification, the assembly is coiled without tight bends and packed with end protection. Labels can cross-reference the customer cable schedule, OEM part number and length. This supports both receiving checks and later moves, adds or changes. Standard protective packing is used by default, with project documentation arranged when requested.
Frequently Asked Questions
Is this an original equipment manufacturer cable?
No. It is manufactured by HT under our own manufacturer identity.
Can different brands be connected with the same assembly?
Only where both hosts explicitly support the complete interface and compatibility arrangement. Document each end and select the appropriate brand-specific product when required.
Does this order code cover multiple lengths?
No. QSFP56 to QSFP56-200G-ACC-7M23FT refers here to 7m (23ft). Every other verified length has a separate part number and page in the length list.
Are separate transceivers or patch leads required?
No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.