SFP112 to SFP112-100G-DAC-0.5M2FT 100G SFP112 PAM4 Passive Copper Twinax Cable, 0.5m (2ft)

This page covers one precise cable-schedule item: Generic SFP112 to SFP112-100G-DAC-0.5M2FT in 0.5m (2ft), supporting 100G operation through SFP112 to SFP112. The complete DAC assembly is identified separately from other lengths and includes verified specifications, change-control-friendly ordering details and live-link factory checks.
OEM Part Number: SFP112 to SFP112-100G-DAC-0.5M2FTHT Part Number: SFP112 to SFP112-100G-DAC-0.5M2FT
Product Highlights
- HT-manufactured DAC assembly in 0.5m (2ft)
- 100G connectivity at 100Gbps
- Interface configuration: SFP112 to SFP112
- Fixed length and part number: 0.5m (2ft), SFP112 to SFP112-100G-DAC-0.5M2FT
- Cable construction: Passive Twinax
- Conductor specification: 28AWG
- Maximum power consumption: <0.15W
- Minimum bend radius: 20mm
Specifications
| HT Part Number | SFP112 to SFP112-100G-DAC-0.5M2FT |
|---|---|
| Manufacturer | HT |
| Connector Type | SFP112 to SFP112 |
| Max Data Rate | 100Gbps |
| Minimum Bend Radius | 20mm |
| Wire AWG | 28AWG |
| Cable Length | 0.5m (2ft) |
| Jacket Material | PVC (OFNR) |
| Cable Type | Passive Twinax |
| Compatible | Generic |
| Power Consumption | <0.15W |
| Power Supply | 3.3V |
| Temperature | 0 to 70°C (32 to 158°F) |
| Application | 100G Ethernet |
| Modulation Format | 100G-PAM4 to 100G-PAM4 |
| Protocol | CMIS Rev5.0, SFF-8024 |
Signal and Lane Configuration
The listed modulation format is 100G-PAM4 to 100G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.
Structured Pathways and Serviceability
Treat the direct-attach assembly as part of the permanent pathway plan even when the link is expected to be temporary. Follow the intended horizontal and vertical managers, maintain the specified bend radius and leave service access around both ports. A small, supported service allowance is preferable to excess slack concealed inside a rack or placed under cable-tie pressure. For this assembly, the listed conductor specification is 28AWG; the minimum bend radius is 20mm; the stated power consumption is <0.15W; the jacket material is PVC (OFNR).
Power and Thermal Planning
The rated power consumption is <0.15W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
Cable Construction and Routing
This assembly uses 28AWG conductors, PVC (OFNR) jacket, minimum bend radius 20mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
Network and Protocol Considerations
The intended application is 100G Ethernet.
Passive Copper Operation
A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.
Length Selection and Installation Planning
The 0.5m (2ft) length is suited to closely aligned ports where excessive slack would obstruct airflow or complicate dressing. Measure the actual port-to-port path before choosing SFP112 to SFP112-100G-DAC-0.5M2FT; even a short assembly must retain the specified bend radius and should never be pulled tight behind the equipment.
Position Within the Length Range
SFP112 to SFP112-100G-DAC-0.5M2FT is the shortest of 5 verified length options in this family. It is the preferred choice when the port positions are close and cable slack must be kept to a minimum. The next option is SFP112 to SFP112-100G-DAC-1M3FT at 1m (3ft), adding 0.5m for a less direct routing path; selecting it unnecessarily would leave more cable to dress.
Ordering Information
Include the part number, fixed length, quantity and required pathway or rack grouping in the order information. The host model and firmware release are useful for change-controlled deployments. Different lengths should remain separate order lines so delivered labels and packing records agree with the pathway plan. This page’s fixed configuration is 0.5m (2ft); another length must be quoted under its corresponding part number.
Generic Compatibility and Factory Testing
Verification covers the physical connectors, expected host identity and an operating link with available diagnostic indications. We distinguish this complete check from a simple continuity test. Platform model and software release can be reviewed in advance where the installation has strict documentation or change-control requirements. The check includes link stability and diagnostic indications, followed by a final inspection of both ends.
Shipping and Lead Time
Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. Delivery can be arranged by courier, air freight or sea freight, and goods may instead be handed to an appointed forwarder or shipped on the customer’s courier account.
Quality Assurance and Packaging
After connector inspection and link verification, the assembly is coiled without tight bends and packed with end protection. Labels can cross-reference the customer cable schedule, OEM part number and length. This supports both receiving checks and later moves, adds or changes. Volume orders can include customer references on the labels and carton list.
Frequently Asked Questions
Is this an original equipment manufacturer cable?
No. It is manufactured by HT under our own manufacturer identity.
Does this order code cover multiple lengths?
No. SFP112 to SFP112-100G-DAC-0.5M2FT refers here to 0.5m (2ft). Every other verified length has a separate part number and page in the length list.
Are separate transceivers or patch leads required?
No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.
Can excess cable be folded into a compact bundle?
No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.
SFP112 to SFP112-100G-DAC-0.5M2FT