Brocade XBR-TWX-0101 Compatible 10G SFP+ Active Copper Twinax Cable, 1m (3ft)

The XBR-TWX-0101 compatible cable combines 10G ACC connectivity with a defined 1m (3ft) pathway between SFP+ to SFP+ interfaces. It is intended for Brocade equipment and is documented here as a distinct order code, allowing cable schedules, service access and related length selections to be reviewed before installation.
OEM Part Number: XBR-TWX-0101HT Part Number: XBR-TWX-0101
Product Highlights
- Compatible alternative to Brocade XBR-TWX-0101
- 10G connectivity at 10Gbps
- Interface configuration: SFP+ to SFP+
- Fixed length and part number: 1m (3ft), XBR-TWX-0101
- Cable construction: Active Twinax
- Conductor specification: 30AWG
- Maximum power consumption: ≤0.5W
- Minimum bend radius: 23mm
Specifications
| HT Part Number | XBR-TWX-0101 |
|---|---|
| Brocade Compatible | XBR-TWX-0101 |
| Manufacturer | HT |
| Connector Type | SFP+ to SFP+ |
| Max Data Rate | 10Gbps |
| Minimum Bend Radius | 23mm |
| Wire AWG | 30AWG |
| Cable Length | 1m (3.28ft) |
| Jacket Material | PVC (OFNR) |
| Cable Type | Active Twinax |
| Temperature | 0 to 70°C (32 to 158°F) |
| Power Consumption | ≤0.5W |
| Power Supply | 3.3V |
| Protocols | 1x InfiniBand QDR, DDR, SDR, 10 Gigabit Ethernet, Fibre Channel |
Power and Thermal Planning
The rated power consumption is ≤0.5W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
Position Within the Length Range
XBR-TWX-0101 is the shortest of 5 verified length options in this family. It is the preferred choice when the port positions are close and cable slack must be kept to a minimum. The next option is XBR-TWX-0301 at 3m (10ft), adding 2m for a less direct routing path; selecting it unnecessarily would leave more cable to dress.
Structured Pathways and Serviceability
Treat the direct-attach assembly as part of the permanent pathway plan even when the link is expected to be temporary. Follow the intended horizontal and vertical managers, maintain the specified bend radius and leave service access around both ports. A small, supported service allowance is preferable to excess slack concealed inside a rack or placed under cable-tie pressure. For this assembly, the listed conductor specification is 30AWG; the minimum bend radius is 23mm; the stated power consumption is ≤0.5W; the jacket material is PVC (OFNR).
Cable Construction and Routing
This assembly uses 30AWG conductors, PVC (OFNR) jacket, minimum bend radius 23mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
Network and Protocol Considerations
The intended application is determined by the host interface and protocol support. Listed interface and protocol references include 1x InfiniBand QDR, DDR, SDR, 10 Gigabit Ethernet, Fibre Channel. Confirm that the host firmware and port configuration support the same operating mode.
Length Selection and Installation Planning
At 1m (3ft), XBR-TWX-0101 is a practical choice for direct connections within one rack. Route the cable along the intended management path rather than pulling it diagonally across adjacent connectors, and leave enough clearance for insertion, removal and front-panel airflow.
Ordering Information
Include the part number, fixed length, quantity and required pathway or rack grouping in the order information. The host model and firmware release are useful for change-controlled deployments. Different lengths should remain separate order lines so delivered labels and packing records agree with the pathway plan. Keep XBR-TWX-0101 associated with 1m (3ft) throughout the order and receiving record.
Brocade Compatibility and Factory Testing
Verification covers the physical connectors, expected host identity and an operating link with available diagnostic indications. We distinguish this complete check from a simple continuity test. Platform model and software release can be reviewed in advance where the installation has strict documentation or change-control requirements. Both connectors are examined before the operating test, which includes link stability and diagnostic indications.
Shipping and Lead Time
Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. Worldwide courier services are available, with air or sea freight for consolidated shipments; freight-collect delivery and coordination with a customer’s logistics provider can be arranged.
Quality Assurance and Packaging
After connector inspection and link verification, the assembly is coiled without tight bends and packed with end protection. Labels can cross-reference the customer cable schedule, OEM part number and length. This supports both receiving checks and later moves, adds or changes. Standard protective packing is used by default, with project documentation arranged when requested.
Frequently Asked Questions
Is this an original Brocade cable?
No. It is an HT-manufactured compatible alternative for equipment that specifies Brocade XBR-TWX-0101.
Will any matching connector operate at the same speed?
Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.
What details assist a compatibility review?
Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.
How should an unused assembly be stored?
Protect both connector ends, keep the cable in a loose bend-safe coil and retain its part-number label so the length and compatibility identity remain traceable.
XBR-TWX-0101