Intel XXVAOCBL4M Compatible 25G SFP28 Active Optical Cable, 4m (13ft)

The XXVAOCBL4M compatible cable combines 25G AOC connectivity with a defined 4m (13ft) pathway between SFP28 to SFP28 interfaces. It is intended for Intel equipment and is documented here as a distinct order code, allowing cable schedules, service access and related length selections to be reviewed before installation.
OEM Part Number: XXVAOCBL4MHT Part Number: XXVAOCBL4M
Product Highlights
- Compatible alternative to Intel XXVAOCBL4M
- 25G connectivity at 25Gbps
- Interface configuration: SFP28 to SFP28
- Fixed length and part number: 4m (13ft), XXVAOCBL4M
- Minimum bend radius: 30mm
Specifications
| HT Part Number | XXVAOCBL4M |
|---|---|
| Intel Compatible | XXVAOCBL4M |
| Manufacturer | HT |
| Connector Type | SFP28 to SFP28 |
| Max Data Rate | 25Gbps |
| Minimum Bend Radius | 30mm |
| Cable Length | 4m (13.12ft) |
| Jacket Material | OFNP |
| Temperature | 0 to 70°C (32 to 158°F) |
Cable Construction and Routing
This assembly uses OFNP jacket, minimum bend radius 30mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
Integrated Optical Assembly
The optical engines and fiber are permanently integrated into this AOC. There are no detachable optical modules to clean or exchange. Handle the complete assembly by its connector housings and cable, and keep both ends matched to the same interface specification.
Length Selection and Installation Planning
The 4m (13ft) length gives XXVAOCBL4M more freedom for adjacent-rack and row-end deployments. The integrated optical assembly should be supported along its route without tight bends or connector pull loads; the AOC specification and host support must still match the intended link.
Position Within the Length Range
XXVAOCBL4M occupies the middle of this family between XXVAOCBL3M at 3m (10ft) and XXVAOCBL5M at 5m (16ft). It adds 1m over the shorter option for extra routing clearance, while the next longer version adds another 1m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.
Structured Pathways and Serviceability
Treat the direct-attach assembly as part of the permanent pathway plan even when the link is expected to be temporary. Follow the intended horizontal and vertical managers, maintain the specified bend radius and leave service access around both ports. A small, supported service allowance is preferable to excess slack concealed inside a rack or placed under cable-tie pressure. For this assembly, the minimum bend radius is 30mm; the jacket material is OFNP.
Ordering Information
Include the part number, fixed length, quantity and required pathway or rack grouping in the order information. The host model and firmware release are useful for change-controlled deployments. Different lengths should remain separate order lines so delivered labels and packing records agree with the pathway plan. This page’s fixed configuration is 4m (13ft); another length must be quoted under its corresponding part number.
Intel Compatibility and Factory Testing
Verification covers the physical connectors, expected host identity and an operating link with available diagnostic indications. We distinguish this complete check from a simple continuity test. Platform model and software release can be reviewed in advance where the installation has strict documentation or change-control requirements. Both connectors are examined before the operating test, which includes receive activity and diagnostic indications.
Shipping and Lead Time
Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. Worldwide courier services are available, with air or sea freight for consolidated shipments; freight-collect delivery and coordination with a customer’s logistics provider can be arranged.
Quality Assurance and Packaging
After connector inspection and link verification, the assembly is coiled without tight bends and packed with end protection. Labels can cross-reference the customer cable schedule, OEM part number and length. This supports both receiving checks and later moves, adds or changes. Standard protective packing is used by default, with project documentation arranged when requested.
Frequently Asked Questions
Is this an original Intel cable?
No. It is an HT-manufactured compatible alternative for equipment that specifies Intel XXVAOCBL4M.
Can excess cable be folded into a compact bundle?
No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.
Will any matching connector operate at the same speed?
Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.
What details assist a compatibility review?
Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.