You are here Transceivers DAC-QSFP-2QSFP28-50G-1M

Dell DAC-QSFP-2QSFP28-50G-1M Compatible 100G QSFP28 4 x 25G NRZ to 2 x 50G QSFP28 2 x 25G NRZ Passive Copper Breakout Cable, 1m (3ft)

Dell DAC-QSFP-2QSFP28-50G-1M Compatible 100G QSFP28 4 x 25G NRZ to 2 x 50G QSFP28 2 x 25G NRZ Passive Copper Breakout Cable, 1m (3ft)

The DAC-QSFP-2QSFP28-50G-1M compatible cable combines 100G DAC connectivity with a defined 1m (3ft) pathway between QSFP28 to 2x SFP28 interfaces. It is intended for Dell equipment and is documented here as a distinct order code, allowing cable schedules, service access and related length selections to be reviewed before installation.

OEM Part Number: DAC-QSFP-2QSFP28-50G-1MHT Part Number: DAC-QSFP-2QSFP28-50G-1M

Product Highlights

  • Compatible alternative to Dell DAC-QSFP-2QSFP28-50G-1M
  • 100G connectivity at 100Gbps
  • Interface configuration: QSFP28 to 2x SFP28
  • Fixed length and part number: 1m (3ft), DAC-QSFP-2QSFP28-50G-1M
  • Cable construction: Passive Breakout DAC
  • Conductor specification: 30AWG
  • Maximum power consumption: 0.5W
  • Minimum bend radius: 10D/5D (Dynamic/Static)

Specifications

HT Part NumberDAC-QSFP-2QSFP28-50G-1M
Dell CompatibleDAC-QSFP-2QSFP28-50G-1M
ManufacturerHT
Form FactorQSFP28 to 2x SFP28
Max. Data Rate100Gbps
MediaCopper
Cable TypePassive Breakout DAC
Cable Length1m (3ft)
Jacket MaterialPVC (OFNR)
Minimum Bend Radius10D/5D (Dynamic/Static)
Wire AWG30AWG
Max. Power Consumption0.5W
Modulation FormatQSFP28-4x 25G-NRZ SFP28-2x 25G-NRZ
Commercial Temperature Range0-70℃(32 to 158°F)
Application100G/50G Ethernet, 128G Fibre Channel
ProtocolsIEEE 802.3, QSFP28 MSA, SFP-8665, SFF-8636

Signal and Lane Configuration

The listed modulation format is QSFP28-4x 25G-NRZ SFP28-2x 25G-NRZ. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Breakout Port Mapping

The QSFP28 to 2x SFP28 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.

Passive Copper Operation

A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.

Length Selection and Installation Planning

At 1m (3ft), DAC-QSFP-2QSFP28-50G-1M is a practical choice for direct connections within one rack. Route the cable along the intended management path rather than pulling it diagonally across adjacent connectors, and leave enough clearance for insertion, removal and front-panel airflow.

Position Within the Length Range

DAC-QSFP-2QSFP28-50G-1M is the shortest of 3 verified length options in this family. It is the preferred choice when the port positions are close and cable slack must be kept to a minimum. The next option is DAC-QSFP-2QSFP28-50G-2M at 2m (7ft), adding 1m for a less direct routing path; selecting it unnecessarily would leave more cable to dress.

Structured Pathways and Serviceability

Treat the direct-attach assembly as part of the permanent pathway plan even when the link is expected to be temporary. Follow the intended horizontal and vertical managers, maintain the specified bend radius and leave service access around both ports. A small, supported service allowance is preferable to excess slack concealed inside a rack or placed under cable-tie pressure. For this assembly, the listed conductor specification is 30AWG; the minimum bend radius is 10D/5D (Dynamic/Static); the stated power consumption is 0.5W; the jacket material is PVC (OFNR).

Power and Thermal Planning

The rated power consumption is 0.5W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Cable Construction and Routing

This assembly uses 30AWG conductors, PVC (OFNR) jacket, minimum bend radius 10D/5D (Dynamic/Static). These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is 100G/50G Ethernet, 128G Fibre Channel. Listed interface and protocol references include IEEE 802.3, QSFP28 MSA, SFP-8665, SFF-8636. Confirm that the host firmware and port configuration support the same operating mode.

Ordering Information

Include the part number, fixed length, quantity and required pathway or rack grouping in the order information. The host model and firmware release are useful for change-controlled deployments. Different lengths should remain separate order lines so delivered labels and packing records agree with the pathway plan. Quantity and any labeling instructions should be attached specifically to DAC-QSFP-2QSFP28-50G-1M.

Dell Compatibility and Factory Testing

Verification covers the physical connectors, expected host identity and an operating link with available diagnostic indications. We distinguish this complete check from a simple continuity test. Platform model and software release can be reviewed in advance where the installation has strict documentation or change-control requirements. Where supported by the host, link stability and diagnostic indications are reviewed together with the established link.

Shipping and Lead Time

Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. International express, air cargo and sea freight can be selected according to destination and carton volume; customer courier accounts and nominated forwarders are also accepted.

Quality Assurance and Packaging

After connector inspection and link verification, the assembly is coiled without tight bends and packed with end protection. Labels can cross-reference the customer cable schedule, OEM part number and length. This supports both receiving checks and later moves, adds or changes. Neutral packaging and customer-specific packing documentation are available on request.

Frequently Asked Questions

Is this an original Dell cable?

No. It is an HT-manufactured compatible alternative for equipment that specifies Dell DAC-QSFP-2QSFP28-50G-1M.

Will any matching connector operate at the same speed?

Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.

What details assist a compatibility review?

Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.

How should an unused assembly be stored?

Protect both connector ends, keep the cable in a loose bend-safe coil and retain its part-number label so the length and compatibility identity remain traceable.

New Zealand Fiber Optics

New Zealand Fiber Optics

New Zealand Service center: New Zealand 0632, Auckland.

Factory in Asia: Shangxue Industrial Area, Shenzhen

Product Datasheets

For PDF documents of products data sheet or any general inquiry, email info@huihongfiber.com and we will send you the details.

Customer Support

For customer support, please email sales@huihongfiber.com; our Auckland service team will respond promptly.