Juniper Networks JNP-100G-2X50G-1M Compatible 100G QSFP28 4 x 25G NRZ to 2 x 50G QSFP28 2 x 25G NRZ Passive Copper Breakout Cable, 1m(3ft)

The JNP-100G-2X50G-1M compatible cable combines 100G DAC connectivity with a defined 1m(3ft) pathway between QSFP28 to 2x SFP28 interfaces. It is intended for Juniper Networks equipment and is documented here as a distinct order code, allowing cable schedules, service access and related length selections to be reviewed before installation.
OEM Part Number: JNP-100G-2X50G-1MHT Part Number: JNP-100G-2X50G-1M
Product Highlights
- Compatible alternative to Juniper Networks JNP-100G-2X50G-1M
- 100G connectivity at 100Gbps
- Interface configuration: QSFP28 to 2x SFP28
- Fixed length and part number: 1m(3ft), JNP-100G-2X50G-1M
- Cable construction: Passive Breakout DAC
- Conductor specification: 30AWG
- Maximum power consumption: 0.5W
- Minimum bend radius: 10D/5D (Dynamic/Static)
Specifications
| HT Part Number | JNP-100G-2X50G-1M |
|---|---|
| Juniper Networks Compatible | JNP-100G-2X50G-1M |
| Manufacturer | HT |
| Form Factor | QSFP28 to 2x SFP28 |
| Max. Data Rate | 100Gbps |
| Media | Copper |
| Cable Type | Passive Breakout DAC |
| Cable Length | 1m (3ft) |
| Jacket Material | PVC (OFNR) |
| Minimum Bend Radius | 10D/5D (Dynamic/Static) |
| Wire AWG | 30AWG |
| Max. Power Consumption | 0.5W |
| Modulation Format | QSFP28-4x 25G-NRZ SFP28-2x 25G-NRZ |
| Commercial Temperature Range | 0-70℃(32 to 158°F) |
| Application | 100G/50G Ethernet, 128G Fibre Channel |
| Protocols | IEEE 802.3, QSFP28 MSA, SFP-8665, SFF-8636 |
Juniper Deployment Reference
Juniper platform documentation distinguishes straight QSFP28 DAC or AOC connections from DACBO and AOCBO breakout operation. On channelized systems, the host port must be configured for the required breakout mode. Match this HT compatible cable to the exact Juniper part number and the intended platform configuration.
Network and Protocol Considerations
The intended application is 100G/50G Ethernet, 128G Fibre Channel. Listed interface and protocol references include IEEE 802.3, QSFP28 MSA, SFP-8665, SFF-8636. Confirm that the host firmware and port configuration support the same operating mode.
Breakout Port Mapping
The QSFP28 to 2x SFP28 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.
Passive Copper Operation
A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.
Length Selection and Installation Planning
At 1m(3ft), JNP-100G-2X50G-1M is a practical choice for direct connections within one rack. Route the cable along the intended management path rather than pulling it diagonally across adjacent connectors, and leave enough clearance for insertion, removal and front-panel airflow.
Position Within the Length Range
JNP-100G-2X50G-1M occupies the middle of this family between JNP-100G-2X50G-50CM at 0.5m (2ft) and JNP-100G-2X50G-2M at 2m(7ft). It adds 0.5m over the shorter option for extra routing clearance, while the next longer version adds another 1m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.
Structured Pathways and Serviceability
Treat the direct-attach assembly as part of the permanent pathway plan even when the link is expected to be temporary. Follow the intended horizontal and vertical managers, maintain the specified bend radius and leave service access around both ports. A small, supported service allowance is preferable to excess slack concealed inside a rack or placed under cable-tie pressure. For this assembly, the listed conductor specification is 30AWG; the minimum bend radius is 10D/5D (Dynamic/Static); the stated power consumption is 0.5W; the jacket material is PVC (OFNR).
Signal and Lane Configuration
The listed modulation format is QSFP28-4x 25G-NRZ SFP28-2x 25G-NRZ. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.
Power and Thermal Planning
The rated power consumption is 0.5W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
Cable Construction and Routing
This assembly uses 30AWG conductors, PVC (OFNR) jacket, minimum bend radius 10D/5D (Dynamic/Static). These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
Ordering Information
Include the part number, fixed length, quantity and required pathway or rack grouping in the order information. The host model and firmware release are useful for change-controlled deployments. Different lengths should remain separate order lines so delivered labels and packing records agree with the pathway plan. Quantity and any labeling instructions should be attached specifically to JNP-100G-2X50G-1M.
Juniper Networks Compatibility and Factory Testing
Verification covers the physical connectors, expected host identity and an operating link with available diagnostic indications. We distinguish this complete check from a simple continuity test. Platform model and software release can be reviewed in advance where the installation has strict documentation or change-control requirements. Where supported by the host, link stability and diagnostic indications are reviewed together with the established link.
Shipping and Lead Time
Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. Delivery can be arranged by courier, air freight or sea freight, and goods may instead be handed to an appointed forwarder or shipped on the customer’s courier account.
Quality Assurance and Packaging
After connector inspection and link verification, the assembly is coiled without tight bends and packed with end protection. Labels can cross-reference the customer cable schedule, OEM part number and length. This supports both receiving checks and later moves, adds or changes. Standard protective packing is used by default, with project documentation arranged when requested.
Frequently Asked Questions
Is this an original Juniper Networks cable?
No. It is an HT-manufactured compatible alternative for equipment that specifies Juniper Networks JNP-100G-2X50G-1M.
Does this order code cover multiple lengths?
No. JNP-100G-2X50G-1M refers here to 1m(3ft). Every other verified length has a separate part number and page in the length list.
Are separate transceivers or patch leads required?
No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.
Can excess cable be folded into a compact bundle?
No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.
JNP-100G-2X50G-1M