You are here Transceivers SFP112 to SFP112-100G-DAC-2.5M8FT

SFP112 to SFP112-100G-DAC-2.5M8FT 100G SFP112 PAM4 Passive Copper Twinax Cable, 2.5m (8ft)

SFP112 to SFP112-100G-DAC-2.5M8FT 100G SFP112 PAM4 Passive Copper Twinax Cable, 2.5m (8ft)

The SFP112 to SFP112-100G-DAC-2.5M8FT compatible cable combines 100G DAC connectivity with a defined 2.5m (8ft) pathway between SFP112 to SFP112 interfaces. It is intended for Generic equipment and is documented here as a distinct order code, allowing cable schedules, service access and related length selections to be reviewed before installation.

OEM Part Number: SFP112 to SFP112-100G-DAC-2.5M8FTHT Part Number: SFP112 to SFP112-100G-DAC-2.5M8FT

Product Highlights

  • HT-manufactured DAC assembly in 2.5m (8ft)
  • 100G connectivity at 100Gbps
  • Interface configuration: SFP112 to SFP112
  • Fixed length and part number: 2.5m (8ft), SFP112 to SFP112-100G-DAC-2.5M8FT
  • Cable construction: Passive Twinax
  • Conductor specification: 26AWG
  • Maximum power consumption: <0.15W
  • Minimum bend radius: 25mm

Specifications

HT Part NumberSFP112 to SFP112-100G-DAC-2.5M8FT
ManufacturerHT
Connector TypeSFP112 to SFP112
Max Data Rate100Gbps
Minimum Bend Radius25mm
Wire AWG26AWG
Cable Length2.5m (8ft)
Jacket MaterialPVC (OFNR)
Cable TypePassive Twinax
CompatibleGeneric
Power Consumption<0.15W
Power Supply3.3V
Temperature0 to 70°C (32 to 158°F)
Application100G Ethernet
Modulation Format100G-PAM4 to 100G-PAM4
ProtocolCMIS Rev5.0, SFF-8024

Signal and Lane Configuration

The listed modulation format is 100G-PAM4 to 100G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Structured Pathways and Serviceability

Treat the direct-attach assembly as part of the permanent pathway plan even when the link is expected to be temporary. Follow the intended horizontal and vertical managers, maintain the specified bend radius and leave service access around both ports. A small, supported service allowance is preferable to excess slack concealed inside a rack or placed under cable-tie pressure. For this assembly, the listed conductor specification is 26AWG; the minimum bend radius is 25mm; the stated power consumption is <0.15W; the jacket material is PVC (OFNR).

Power and Thermal Planning

The rated power consumption is <0.15W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Cable Construction and Routing

This assembly uses 26AWG conductors, PVC (OFNR) jacket, minimum bend radius 25mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is 100G Ethernet.

Passive Copper Operation

A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.

Length Selection and Installation Planning

The 2.5m (8ft) version is useful when a two-metre run would leave insufficient working slack. Before installation, check the complete horizontal and vertical path so that SFP112 to SFP112-100G-DAC-2.5M8FT reaches both ports without tension at either connector.

Position Within the Length Range

SFP112 to SFP112-100G-DAC-2.5M8FT is the longest of 5 verified length options in this family. Compared with SFP112 to SFP112-100G-DAC-2M7FT at 2m (7ft), it provides 0.5m of additional reach for a longer vertical drop, a wider rack or an adjacent-cabinet route. Confirm that the complete path requires this length, because unused slack still needs supported, bend-safe storage.

Ordering Information

Include the part number, fixed length, quantity and required pathway or rack grouping in the order information. The host model and firmware release are useful for change-controlled deployments. Different lengths should remain separate order lines so delivered labels and packing records agree with the pathway plan. Keep SFP112 to SFP112-100G-DAC-2.5M8FT associated with 2.5m (8ft) throughout the order and receiving record.

Generic Compatibility and Factory Testing

Verification covers the physical connectors, expected host identity and an operating link with available diagnostic indications. We distinguish this complete check from a simple continuity test. Platform model and software release can be reviewed in advance where the installation has strict documentation or change-control requirements. Where supported by the host, link stability and diagnostic indications are reviewed together with the established link.

Shipping and Lead Time

Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. Delivery can be arranged by courier, air freight or sea freight, and goods may instead be handed to an appointed forwarder or shipped on the customer’s courier account.

Quality Assurance and Packaging

After connector inspection and link verification, the assembly is coiled without tight bends and packed with end protection. Labels can cross-reference the customer cable schedule, OEM part number and length. This supports both receiving checks and later moves, adds or changes. Neutral packaging and customer-specific packing documentation are available on request.

Frequently Asked Questions

Is this an original equipment manufacturer cable?

No. It is manufactured by HT under our own manufacturer identity.

Does this order code cover multiple lengths?

No. SFP112 to SFP112-100G-DAC-2.5M8FT refers here to 2.5m (8ft). Every other verified length has a separate part number and page in the length list.

Are separate transceivers or patch leads required?

No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.

Can excess cable be folded into a compact bundle?

No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.

New Zealand Fiber Optics

New Zealand Fiber Optics

New Zealand Service center: New Zealand 0632, Auckland.

Factory in Asia: Shangxue Industrial Area, Shenzhen

Product Datasheets

For PDF documents of products data sheet or any general inquiry, email info@huihongfiber.com and we will send you the details.

Customer Support

For customer support, please email sales@huihongfiber.com; our Auckland service team will respond promptly.